• Title/Summary/Keyword: plumes

Search Result 128, Processing Time 0.023 seconds

A STUDY ON THE PREDICTION OF GROUNDWATER CONTAMINATION USING THE GIS IN HWANAM 2 SECTOR, GYEONGGI PROVINCE, KOREA (GIS를 이용한 경기도 화남2지구의 지하수오염 예측에 관한 연구)

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.4
    • /
    • pp.267-285
    • /
    • 2001
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters,such as structural lineament density and landuse, into conventional DRASTIC medal, and to predict the potential of groundwater contamination using GIS in Whanam 2 Area, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament denisity affects to the behavior of goundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Composite contamination map was achieved as a final result by comparing modified DRASTIC potential and the amount of generation load of several contaminant sources logically. The result could suggest the predictability of the area of contamination potrntial in the respects of hydrogeological aspect and water quality.

  • PDF

Investigation of Contamination Area from Landfill Using the Small-loop Electromagnetic Survey (소형루프 전자탐사를 이용한 폐기물 오염범위 탐지)

  • Song, Sung-Ho;Um, Jae-Yeon;Cho, In-Ky;Jung, Cha-Youn
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.158-163
    • /
    • 2011
  • The small-loop electromagnetic (EM) survey is an effective method to delineate contamination areas and pathways of contaminant plumes from landfill. A multi-frequency small-loop EM survey was applied to find them at landfill area, located in delta region, and checked the results with in-situ surveys including 24 trench excavations and 12 drilling boreholes. The correlation between these two results indicates this survey would be suitable to investigate the contamination area. However, it would be difficult to analyze low resistivity less than 10 ohm-m below 10 m depth in delta area without drilling survey because of a limitation to expand the penetration depth lower than 10 m depth due to the separation of 1.66 m between the two coils of GEM-2.

Retrieval of LIDAR Aerosol Parameter Using Sun/Sky Radiometer at Gangneung, Korea

  • Shin, Sung-Kyun;Lee, Kwon-Ho;Lee, Kyu-Tae
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.175-185
    • /
    • 2017
  • The aerosol optical properties such as depolarization ratio (${\delta}$) and aerosol extinction-to-backscatter ratios (S, LIDAR ratio) and ${\AA}ngstr{\ddot{o}m$ exponent (${\AA}$) derived from measurement with AERONET sun/sky radiometer at Gangneung-Wonju National University (GWNU), Gangneung, Korea ($37.77^{\circ}N$, $128.87^{\circ}E$) during a winter season (December 2014 - February 2015) are presented. The PM concentration measurements are conducted simultaneously and used to identify the high-PM events. The observation period was divided into three cases according to the PM concentrations. We analysed the ${\delta}$, S, and ${\AA}$ during these high PM-events. These aerosol optical properties are calculated by the sun/sky radiometer data and used to classify a type of aerosols (e.g., dust, anthropogenic pollution). The higher values of ${\delta}$ with lower values of S and ${\AA}$ were measured for the dust particles. The mean values of ${\delta}$, S, and ${\AA}$ at 440-870 nm wavelength pair (${\AA}_{440-870}$) for the Asia dust were 0.19-0.24, 36-56 sr, and 0.48, respectively. The anthropogenic aerosol plumes are distinguished with the lower values of ${\delta}$ and higher values of ${\AA}$. The mean values of spectral ${\delta}$ and ${\AA}_{440-870}$ for this case varied 0.06-0.16 and 1.33-1.39, respectively. We found that aerosol columnar optical properties obtained from the sun/sky radiometer measurement are useful to identify the aerosol type. Moreover, the columnar aerosol optical properties calculated based on sun/sky radiometer measurements such as ${\delta}$, S, and ${\AA}$ will be further used for the validation of aerosol parameters obtained from LIDAR observation as well as for quantification of the air quality.

Natural Convection Heat Transfer Past an Outer Rectangular Corner (외부 직각모서리 부근에서의 자연대류 열전달)

  • 신순철;장근식;김승수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.598-605
    • /
    • 1985
  • Laminar natural convection heat transfer past an outer rectangular corner was experimentally investigated by using Mach-Zehnder interferometer. The present geometry represents the case when the plume from a vertical flat plate and that from a horizontal one merge into a single plume. the temperature distribution and the local heat flux were measured in the range of Grashof number 8 * 10$^{4}$$r_{LH}$ <1.25 * 10$^{6}$ . The effect of the geometric aspect ratio was also considered. Correlation for the average Nusselt number vs. Grashof number was obtained by using a newly determined characteristic length. To determine the interaction of the plumes, the present results were compared with the similarity solutions available from the isolated vertical and isolated horizontal flat plates.

Difference in Macrobenthic Community Structures at Thermal Effluent Discharge Areas of Two Nuclear Power Plants in Korea (원자력발전소의 온배수 배출해역에서 대형 저서동물 군집구조의 차이)

  • Maeng, Jun-Ho;Kim, Keun-Yong;Kim, Young Ryun;Shon, Myung Baek;Kim, Jin Hee;Son, Min Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.157-165
    • /
    • 2015
  • This study investigated and compared sediment properties and macrobenthic community structures within heated effluent plumes at the discharge areas of Kori Nuclear Power Plant (KNPP) and Sinkori Nuclear Power Plant (SNPP) in Korea, which have different thermal effluent discharge systems. There were significant differences in sand, clay and organic carbon contents between sediments at the two discharge areas. Species richness and abundance of macrobenthos were higher at the SNPP discharge area than at that of the KNPP, although the values at both areas were comparable to previous studies in coastal areas of eastern Korea.

A Study on the Prediction of Groundwater Contamination using GIS (GIS를 이용한 지하수오염 예측에 관한 연구)

  • Jo, Si-Beom;Shon, Ho-Woong;Lee, Kang-Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.2 s.29
    • /
    • pp.17-28
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and land-use, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Hwanam 2 District, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice-layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Groundwater contamination potential map was achieved as a final result by comparing modified DRASTIC potential and the amount of pollutant load logically. The result suggest the predictability of contamination potential in a specified area in the respects of hydrogeological aspect and water quality.

  • PDF

Applicability of Groundwater Quality Monitoring Network Design Methodologies (지하수 수질관측망 설계방법론의 적용성 검토)

  • Lee, Sang-Il
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.685-694
    • /
    • 1998
  • Protection of groundwater resources from contamination has been of increasing concern throughout the past decades. In practice, however, groundwater monitoring is performed based on the experience and intuition of experts or on the convenience. In dealing with groundwater contamination, we need to know what contaminants have the potential to threat the water quality and the distribution and concentration of the plumes. Monitoring of the subsurface environment through remote geophysical techniques or direct sampling from wells can provide such information. Once known, the plume can be properly managed. Evaluation of existing methodologies for groundwater monitoring network design revealed that one should select an appropriate design method based on the purpose of the network and the availability of field information. Integer programming approach, one of the general purpose network design tools, and a cost to-go function evaluation approach for special purpose network design were tested for field applicability. For the sam contaminated aquifer, two approaches resulted in different well locations. The amount of information, however, was about the same.

  • PDF

The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume (화재위치에 따른 $CO_2$소화제 전달특성)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2003
  • To analyze the transfer characteristics of $CO_2$ extinguishant when extinguishant is injected into a closed space similar to a marine engine room, a numerical simulation was performed. Flow and Concentration fields are calculated according with the variation of the fire plume,s location. The results show that tile variation of fire plumes, location greatly effected on the flow patterns and the characteristics of $CO_2$ extinguishant transfer. In case of the fire plume located at left region of the 2nd floor center in the engine room consisted of first and second floor, The effects similar to the air curtain is found and cut off the mass transfer. In the characteristics with hight, the iso-concentration line below the extinguishable limit is formed in the left region of the 1st and 2nd floor center after the $CO_2$ extinguishant is completely injected. therefore I think that the results of this study are considered to arrange the $CO_2$ injection nozzles for the $CO_2$ fire fighting equipments.

Provenance of Sediments and Evidence of Hydrothermal Venting Adjacent to the Fonualei Rift and Spreading Center, Lau Basin, Southwest Pacific (남서태평양 라우분지 푸누아레이 열곡확장대 인근 퇴적물의 기원과 열수 분출의 증거)

  • Kim, Mun Gi;Hyeong, Kiseong;Seo, Inah;Yoo, Chan Min
    • Ocean and Polar Research
    • /
    • v.42 no.1
    • /
    • pp.33-47
    • /
    • 2020
  • The bulk and partition geochemistry was studied in two sediment cores collected from the axial valley of the north-central Fonualei Rift and Spreading Center (FRSC), Lau back-arc Basin, southwest Pacific. The sediments consist of mostly volcanic ash, although minor amounts of biogenic and other components were present in some intervals. The major element composition of bulk sediments recalculated to a carbonate-free basis was in good agreement with the magma compositions of the adjacent Tofua Arc and the FRSC, with only significant difference in Mn content. The enrichment of Mn and other associated elements (e.g. Cu, Co, Ni, and P) is attributed to hydrothermal input to the sediments, as evidenced by their significant partitioning in the non-detrital phases according to the partition geochemistry. Hydrogenetic and diagenetic inputs were assessed to be relatively insignificant. Estimated hydrothermal Mn fluxes during the Holocene ranged between 5.0 and 37.1 mg cm-2 kyr-1, with the higher values in younger sediments, suggesting enhanced hydrothermal activity. The hydrothermal Mn fluxes comparable to or higher than those reported from other spreading centers with strong hydrothermal activities may indicate the presence of unknown hydrothermal vent sites and/or topographic restriction on the dispersal of hydrothermal plumes in the northern part of the FRSC.

Long-Distance Plume Detection Simulation for a New MWIR Camera (장거리 화염 탐지용 적외선 카메라 성능 광선추적 수치모사)

  • Yoon, Jeeyeon;Ryu, Dongok;Kim, Sangmin;Seong, Sehyun;Yoon, Woongsup;Kim, Jieun;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.245-253
    • /
    • 2014
  • We report a realistic field-performance simulation for a new MWIR camera. It is designed for early detection of missile plumes over a distance range of a few hundred kilometers. Both imaging and radiometric performance of the camera are studied by using real-scale integrated ray tracing, including targets, atmosphere, and background scene models. The simulation results demonstrate that the camera would satisfy the imaging and radiometric performance requirements for field operation.