• Title/Summary/Keyword: plaxis

Search Result 84, Processing Time 0.017 seconds

Behavior of Tunnel Due to Adjacent Ground Excavation with Pre-loading on Braced Wall (근접 굴착시 흙막이벽 버팀대 선행하중 재하에 따른 터널의 거동)

  • Kim, Il;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.163-174
    • /
    • 2007
  • A New pre-loading system, through which a large pre-load could be charged was developed and applied to the braced wall in order to stabilize the adjacent tunnel. A pre-load larger than the designated axial force of bracing was imposed to prevent the horizontal displacement of the braced wall during the ground excavation. For this purpose, real scale model tests (1/10) were conducted, without and with pre-load on braced wall. And numerical analyses were performed for both the cases without and with pre-load, which were half (50%) and full (100%) respectively, and larger scale of the design axial farce of bracing. FEM program called PLAXIS was used for numerical analysis. As a result, it was found that the stability of the existing tunnel adjacent to the braced wall could be greatly enhanced when the horizontal displacement of braced wall was reduced by applying a pre-load, which was larger than the designated axial force of bracing.

Performance of Horizontal Drainage in the Slope Using Numerical Analysis (수치해석을 이용한 비탈면 수평배수공의 성능 분석)

  • Sangyun Kim;Hoki Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.5-11
    • /
    • 2024
  • Due to the high proportion of mountainous terrain in Korean territory and the concentration of heavy rainfall during the summer season, concerns arise about the potential decrease in slope stability caused by rainfall. Installing slope drainage facilities mitigates the rise in groundwater levels due to infiltration, thus enhancing slope stability. Horizontal drains, classified as auxiliary facilities among drainage systems, lack established installation standards and related research. Slopes with installed horizontal drains have been confirmed to exhibit higher safety factors compared to those without. Furthermore, the safety factor of mimicking horizontal drains by increasing the permeability coefficient of the surrounding ground was compared with that of the conventional simulation method using the Drain function. As a result of the comparison, it was confirmed that the installation length showed better drainage performance than the installation angle in the drainage performance of the horizontal drainage hole, and it was judged that the installation length was a more important factor.

Measurement of ground behaviour due to tunnelling using No-target program in laboratory model test (실내모형시험에서 No-target 프로그램을 이용한 터널 굴착으로 인한 지반거동 측정)

  • Lee, Jong-Hyun;Lee, Chang-No;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.397-418
    • /
    • 2019
  • It is very important to understand and analyze the interactive behaviour between ground and adjacent structures due to tunneling. With many technological advancement in modern society, numerous methods for analyzing the interactive behaviour are used in a wide range of civil engineering fields. Close range photogrammetry is mainly being used in the field of geotechnical engineering and research on measuring methods associated with GeoPIV has been currently increased. Originally, the close range photogrammetry using target points and aluminum rods for VMS (Vision Measurement System) program has been used. However, applying this has a problem that external errors can be occurred because the target points are artificially installed by hand, and if the grid between points is being wider or narrower, deficient data can be obtained. Therefore, in this study, MATLAB-based No-target program that can analyze displacement without using target was developed. Additionally, this study focused on comparison and verification with existing program through numerical analysis and laboratory model test. Three cases of Greenfield condition, Strip foundation, and Pile foundation were analyzed. From results of VMS program and No-target program, the error rate and reliability of the total displacement and the vertical displacement were analyzed. It was also compared and verified through the finite element numerical program, PLAXIS.

A Study on Lateral Displacement of Caisson Constructed on Improved Ground (개량 지반에 설치된 케이슨의 측방변위에 대한 연구)

  • Kim, Myunghak;Lee, Sangwook;Yoon, Minseung;Han, Byungwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.33-41
    • /
    • 2011
  • In case of building up port facilities on soft ground, unsymmetrical surcharge of embankment, which make the excess pore water pressure to increase, causes to occur lateral displacement due to plasticity of soil. A study on lateral displacement and settlement of the caisson, which is installed on improved ground, was accomplished. The field measurement data and calculated values obtained from FEM program of Plaxis were compared and analyzed. For numerical analysis, the properties of soils, constructions stage and time were considered. Lateral displacement was measured at the point of inclinometers installed in front of caisson. Settlement was measured at the center of extra embankment behind of caisson. Comparison of measured and calculated for lateral displacement showed that the calculated value was greater than the measured, and increasing trend was different. The calculated value showed step increasing as step extra embankment applied, whereas the measured gradually was increased. For settlement of embankment, the amount of both measured and calculated were similar, but the trend was different like that of lateral movement.