• Title/Summary/Keyword: plate loading test

Search Result 362, Processing Time 0.023 seconds

Low-Soil Disturbance In-Situ Test Method Development and Its Application : Screw Plate Loading Test (지반의 교란을 최소화 한 원위치시험법 개발 및 적용 : 스크류재하시험)

  • Lee, Yong-Su;Hwang, Woong-Ki;Choi, Yong-Kyu;Kim, Tae-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.977-986
    • /
    • 2009
  • Sampling disturbance can introduce considerable errors in the laboratory estimation of geotechnical properties of soils, and the results obtained from sophisticated sampling and careful laboratory testing are not matching with field behavior. Therefore, it is advantage to adopt in-situ testing techniques for the estimation of geotechnical parameters. Therefore, Screw plate loading test, one of new field test technologies, has been investigated in this study. This test can be utilized to find out important properties of soils such as load-displacement, elastic modulus, and shear strength. The screw plate loading test modified from the plate loading test is an experiment underneath ground by inserting a spiral type of auger screw. The structure and characteristics of the screw plate loading test device was examined in detail. In addition, The new screw plate loading test device was manufactured to refer the previous studies. The reliability of developing screw plate loading test was examined through the analysis of the laboratory test.

  • PDF

Cyclic Loading Test of Anchorage System for Externally Prestressed CFRP Plate (외부긴장 CFRP판용 정착부의 반복하중 실험)

  • Jung, Woo-Tai;Park, Jong-Sup;Park, Young-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.262-265
    • /
    • 2006
  • This paper presents results on static and cyclic loading tests of anchorage system for externally prestressed CFRP plate. A total of 6 specimens have been tested. The specimens can be classified into the concrete surface specimens and the concrete near surface mounted specimens. Static test results before and after cyclic loading test reveal that anchorage system for externally prestressed CFRP plate has static capacity more than CFRP tensile strength.

  • PDF

Deformation Behaviour of Metamorphic Tuff from Plate Loading Test

  • Lee, Young-Nam;Suh, Young-Ho;Kim, Dae-Young
    • Geotechnical Engineering
    • /
    • v.13 no.3
    • /
    • pp.87-100
    • /
    • 1997
  • This paper presents the results of plate loading test and discontinuum analysis, carried out to study the deformation behaviour and determine the deformation modulus of !rletamorphic andesitic tuff found at the site of a underground oil storage facility in Korea. In the plate loading test, the maximum pressure of 14MPa was applied to the bedrock by using a flat jack(1m in diameter) and the rock anchor system for the reaction against the applied pressure. The values of deformation modulus obtained from this test were compared with those of laboratory test, biaxial test and pressuremeter test. The deformation modulus from plate loading test was generally about half of the intact rock modulus, and the mass modulus of the bedrock at the test site may be affected by discontinuities and ranges between 25 and 350pa. Discontinuum analysis was also performed to simulate plate loading test and study the influence of discontinuities on the deformability of rock mass by simulating the presence of joints at the test area.

  • PDF

Evaluation of Correlation between Subgrade Reaction Modulus and Strain Modulus Using Plate Loading Test (평판재하시험을 이용한 지반반력계수와 변형률계수의 상관관계 평가)

  • Kim, Dae-Sang;Park, Seong-Yong;Kim, Soo-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.57-67
    • /
    • 2008
  • Two test methods, nonrepetitive plate loading test (NPLT) and repetitive plate loading test (RPLT) are being used to control the quality of compaction through the evaluation of the stiffness of subgrade soils in the Korea railway industry. Subgrade reaction modulus ($k_{30}$) from the NPLT and strain modulus ($E_v$) from the RPLT are the index values to check them. The methods have similar aspects, but they differ in the modulus evaluation method, the numbers of loading stage, termination procedures, etc. This paper analyses the differences of the two test methods and evaluates the relationship between subgrade reaction modulus and strain modulus. In order to develop the relationship, total 22 tests were performed including the NPLT and the RPLT at the 6 original grounds, and 5 upper or lower subgrades in Kyungbu High Speed Railway II stage construction sites. According to the soil conditions, the relationship between subgrade reaction modulus and strain modulus was proposed with corrections by considering strain states, mean confining pressures, and Poisson's ratio.

A Research for Computation of Bearing Capacity and Settlement of Foundation Considering Scale Effect in Weathered-granite Layer (화강풍화토에서 Scale Effect를 고려한 기초의 지지력 및 침하량 산정에 관한 연구)

  • 박용부;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.131-139
    • /
    • 2004
  • When calculating bearing capacity and settlement of actual foundation from plate test result fur design and construction of shallow foundation, scale effect should be considered. But, adequate guide and test result of scale effect were not prepared yet in Korea. So, to analyze the relations of bearing capacity and settlement as the difference of loading plate sizes, model test and field loading test were performed with different loading plate on weathered-granite layer. Model tests were conducted with water content, compaction number, saturated unit weight and plate size(Dl5, 25cm) in soil-box$(2,000\times 2,000\times 1,000mm)$ formed soil layer. Field loading tests were carried out with diameters of loading plate$(D15, 25, 30, 40, 75\times 75, 140\times 210cm)$ on the same soil condition. Finally, we presented the prediction formula of bearing and settlement for computating scale offset in design of shallow foundation through result analysis of load test and numerical simulation on weathered soil and rock.

Fatigue Test of Concrete Deck Plate Bridge (상판 조립식 PC 교량의 피로 시험 연구)

  • Goo, Min-Se;Chung, Ran;Kim, Gung-Hwan;Kim, Jong-Seung;Roh, Yeong-Sook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.74-79
    • /
    • 1991
  • In order to investigate the behavior of newly developed PC deck plate bridges, 1/2 scale model specimen was tested under the 2 million cycles of fatigue loading. Forces between PC members were transfered by shear keys located at the faces of deck plate and girders. The test results showed that the test specimen maintained its original strength after 2 million cycles of fatigue loading.

  • PDF

Characteristics of Bearing Capacity and Settlement According to the Difference of Loading Plate Sizes (재하판의 크기에 따른 지지력 및 침하특성)

  • 정형식;김도열
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.179-188
    • /
    • 2002
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from plate-load test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were performed with four different sizes of square plate, which are B=10, 15, 20, and 25cm respectively, on five different kinds of subsoils. Test results showed that the ultimate bearing capacity of a footing on the sand did not increase proportional to the traditional formula and the bearing capacity on the clay also increased a little with increasing the size of loading plate. The settlement of test plate on the sand did not increase as the traditional formula of Terzaghi and Peck (1967), and the settlement on the clay also did not increase proportional to the traditional formula.

Behavior of High-Speed Rail Roadbed Reinforced by Geogrid under Cyclic Loading (지오그리드로 보강한 고속철도 노반의 거동 특성)

  • 신은철;김두환
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.84-91
    • /
    • 2000
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. With the test results, the bearing capacity ratio, elastic rebound ratio, subgrade modulus and the strain of geogrids under loading were investigated. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to estimate the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

Application of Scale Effect in Estimating Bearing Capacity and Settlement of Footing from Plate-Load Test (평판재하시험으로부터 실제기초의 지지력 및 침하량 산정시 Scale Effect)

  • 정형식;김도열
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.350-357
    • /
    • 2002
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from Plate-Load Test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were peformed with four different sizes of square plate, which is B=10, 15, 20 and 25cm respectively, on five different kinds of subsoil, which is pure sand(100:0), sand-clay mixed soil(75:25, 50:50, 25:75), and pure clay(0:100). Based on the analyzed results, this paper also proposed a method of bearing capacity and settlement determination, where scale effect is considered depending on the mixing ratio of sand and clay. Applying the formular proposed in this research to field problems, it is expected that evaluation of bearing capacity and settlement of footings can be more reliable and more economic construction can be achieved.

  • PDF

Improvement of pavement foundation response with multi-layers of geocell reinforcement: Cyclic plate load test

  • Khalaj, Omid;Tafreshi, Seyed Naser Moghaddas;Mask, Bohuslav;Dawson, Andrew R.
    • Geomechanics and Engineering
    • /
    • v.9 no.3
    • /
    • pp.373-395
    • /
    • 2015
  • Comprehensive results from cyclic plate loading at a diameter of 300 mm supported by layers of geocell are presented. The plate load tests were performed in a test pit measuring $2000{\times}2000mm$ in plane and 700 mm in depth. To simulate half and full traffic loadings, fifteen loading and unloading cycles were applied to the loading plate with amplitudes of 400 and 800 kPa. The optimum embedded depth of the first layer of geocell beneath the loading plate and the optimum vertical spacing of geocell layers, based on plate settlement, are both approximately 0.2 times loading plate diameter. The results show that installation of the geocell layers in the foundation bed, increase the resilient behavior in addition to reduction of accumulated plastic and total settlement of pavement system. Efficiency of geocell reinforcement was decreased by increasing the number of the geocell layers for all applied stress levels and number of cycles of applied loading. The results of the testing reveal the ability of the multiple layers of geocell reinforcement to 'shakedown' to a fully resilient behavior after a period of plastic settlement except when there is little or no reinforcement and the applied cyclic pressure are large. When shakedown response is observed, then both the accumulated plastic settlement prior to a steady-state response being obtained and the resilient settlements thereafter are reduced. The use of four layers of geocell respectively decreases the total and residual plastic settlements about 53% and 63% and increases the resilient settlement 145% compared with the unreinforced case. The inclusion of the geocell layers also reduces the vertical stress transferred down through the pavement by distributing the load over a wider area. For example, at the end of the load cycle of the applied pressure of 800 kPa, the transferred pressure at the depth of 510 mm is reduced about 21.4%, 43.9%, 56.1% for the reinforced bases with one, two, and three layers of geocell, respectively, compared to the stress in the unreinforced bed.