• Title/Summary/Keyword: plate characteristic length

Search Result 49, Processing Time 0.03 seconds

Driving Characteristic of Thin-type Ultrasonic Motor (박형 초음파 모터의 구동특성)

  • Jeong, Seong-Su;Jun, Ho-Ik;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.343-343
    • /
    • 2008
  • Newly designed structure of a thin ultrasonic rotary motor was proposed. Thin brass plate was used as a cross shaped vibrator and eight ceramic plates were attached on the upper and bottom sides of the brass plate as in Figure 1. The thin type ultrasonic motor has the structure adherent piezoelectric ceramic on the top and bottom surface of the thin elastic body. The direction of polarization is decided so as to occur the elliptical displacement in regular sequence at touch point A, B, C and D of stator contacted with rotor. By applying two electric fields which have 90 degree phase difference on the ceramics, each contact points make rotational displacements as in figure 2. Finite element analysis program ATILA was used to find the optimal size of the stator. As a result of the simulation, elliptical displacements of the tips were obtained at off-resonance frequencies. The maximum displacements of the contact tips were obtained at the length of 16[mm], width of 6[mm] and thickness of 0.4[mm]. Changes of the resonance frequencies were inversely proportional to the length of ceramic and proportional to the width of ceramic. Elliptical motions of the contact tips. of the stator were consistently obtained at off resonance frequencies. From a prototype motor, speed of 600[rpm] was obtained at 20[Vrms].

  • PDF

A Study on Experiment and Structural Analysis for High-Durability of Orthotropic Steel Deck Bridge (고내구성을 위한 강바닥판교의 실험 및 해석 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.462-467
    • /
    • 2007
  • From the research which it sees verification of the whole interpretation and local interpretation of the durability steel deck bridge a static test and it produces the test body which it sells with character and it executes smallness pul lek detailed interpretation it leads and the appropriate characteristic of smallness pul lek detailed interpretation and to sleep a nominal stress price and it compares it judges it does. The stress quality from each structure region which it follows in load stock location it analyzes and from the hazard which evaluates, the objective region the length rib and the bottom grater weld zone, the length rib and width rib connection department and the width rib with the father it divided. It investigated the stress distribution of the test body from these objective location, FEM interpretation it led and the conduct against each structure state tax it analyzed. General conduct the load stock location the floor plate is located in the center with interpretation price together symmetry characteristic to seem, it cannot be like that it cannot there is one actual test price. Like this reason the length rib and width rib connection actually production even production characteristic security it is a day when it is impossible with the curvature junction department which it blows, it follows in examination body deferment condition and form feed with the fact that it is visible a big difference even with error of some it becomes. Consequently for a data and the research which are more accurate it is judged with the fact that the effort which is prudent will be necessary.

  • PDF

Characteristic Analysis of Air-gap Control System in Performance Test Machine of a LIM for Railway Transit (철도차량용 선형유도전동기 성능시험기의 공극조절 시스템 특성 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Park, Hyun-June;Kwon, Sam-Young;Han, Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1955-1961
    • /
    • 2008
  • A lot of researches on a linear induction motor(LIM) have been advanced to realize a traction system with high efficiency and performance for railway transit for a long time. However, most of them are limited in design of a LIM part such as Primary and Secondary. At a LIM which is traveling, the change of an air-gap(It occurs by a construction tolerance of a secondary reaction plate) becomes the cause which decreases a smoother ride and the efficiency of railway transit system. Therefore, uniform air-gap operation of LIM is important issue to improve the system efficiency. However, the researches which control the air-gap length of the LIM with technical and high-cost problem have been not advanced a lot. Therefore, in this research, it is introduced an air-gap control system for performance test machine of a scale-downed LIM which is able to control the air-gap length of the LIM and monitor a variety of performance changes of the propulsion system, and conducted a research on feasibility of the system based on characteristic analysis.

  • PDF

Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt (원자로 냉각재배관 엘보우 및 서포트 스컷트용)

  • Son, Jong-Dong;Lim, Man-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

Heat Transfer Characteristics depending on the Length of a Channel with Pin-Fin Array (핀-휜을 삽입한 채널의 길이에 따른 열전달 특성 변화)

  • Son, Young-Seok;Shin, Jee-Young;Lee, Sang-Rog
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.418-425
    • /
    • 2007
  • The power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Therefore, suitable heat dissipation has become one of the primary limiting factors to ensure the guaranteed performance and reliable operation of the electronic devices. A pin-fin array which may be considered as a porous medium could be used as an alterative cooling system of the electronic equipment. The aim of the present study is to investigate the forced-convective heat transfer characteristics of pin-fin heat exchangers. Convective heat transfer through the pin~fin array is analyzed experimentally based on porous medium approach. The influence of the structure of the pin-fin array including the pin-fin spacing, the pin diameter and plate length on heat transfer characteristic is investigated and compared with the Previous analytical results and existing correlation equations. Nowadays, electronic and mechanical devices become smaller and smaller. In this sense, the main purpose of this study is to decide the optimum pin-fin arrangement to get similar heat transfer performance when the length of the existing cooling system is reduced as a half.

Numerical Analysis of Deformation Mode of Flexible Plate-Type Piezoelectric Module for Evaluating Characteristics of Electrical-Energy Generation (판형 압전 진동자의 굽힘변형 모드에 따른 전압발생 특성에 관한 해석적 연구)

  • Park, Jeong-Hyun;Park, Sang-Hu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.8
    • /
    • pp.735-741
    • /
    • 2015
  • Piezoelectric materials are well-utilized for transforming mechanical vibrations into electrical energy that can be stored and used to power a diversity of devices. In this work, these materials have been studied to improve the efficiency of a piezoelectric system, whereby the shape and vibration mode of a piezoelectric module was changed. The basic shape of the piezoelectric module used in this work comprises a width of 10 mm, a length of 30 mm, and a thickness of 0.2 mm. The structural design of the piezoelectric module is optimized using a Taguchi method to increase the corresponding electrical-energy generation. The maximum terminal voltage was defined as a characteristic value to evaluate the optimal design parameters. Through this work, we propose an optimal structure with an eccentric and centric mass; furthermore, the voltage increase of approximately 26% was obtained by comparing a general plate-vibrating piezosystem with an optimal plate-vibrating piezosystem.

PIV Analysis of Flow around a Submerged Pitch Damping Foil (몰수형 피치댐핑포일 주위 유동의 PIV 해석)

  • Gim, Ok-Sok;Lee, Gyoung-Woo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.5
    • /
    • pp.410-415
    • /
    • 2012
  • An experimental study is carried out to investigate the near-wake characteristics of a NACA 0018 foil with a flat plate. Two-frame grey-level cross correlation PIV method is used to measure the local flow characteristic around a pitch damping foil to control the vertical motion of high speed crafts in a circulating water channel. The analysis also includes angles of attack 10 and 20 degrees respectively. Reynolds number $Re{\fallingdotseq}3.5{\times}10^4$ based on the chord length(C=100mm) of NACA0018 has been applied during the whole experiments. The distance between the foil and the flat plate is D/C=0.5, 1.0 and 1.5 respectively. The channel effect according as the distance between the foil and the flat plate has a close relation with the velocity distributions around the foil. In the wake of 20-degree of attack, the complex turbulent flow and a thick boundary layer are formed due to the processes of vortex generation and dissipation.

Characteristic Analysis of Displacement Behavior of Hollow Rollers with Cross Sectional Area Profiles (중공롤러의 절단면 형상변화에 따른 변형거동 특성해석)

  • Chung, Joon Ki;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.55-61
    • /
    • 2015
  • In this paper, the displacement behavior characteristic of hollow rollers with various cross sectional area profiles and circular plate for load supporting capacity increment has been presented using a finite element method. The FEM results present that the hollow roller with X-shaped or Y-shaped columns between outer tube, middle tube and inner tube reduces a maximum displacement at the middle length of hollow rollers. And the circular plate, which is inserted at the middle of the hollow roller, is very useful to reduce the maximum displacement of hollow rollers with the plate thickness of 30~40mm. This paper presents the weight vs the maximum displacement ratio in which is represented for the optimized design as a function of a hollow roller total weight. The FEM analyzed results recommend the design model 4, 5 and 6 of hollow rollers for decreasing the ratio of maximum displacement and total weight of hollow rollers.

Study on Heat Transfer Characteristic of Shell-and-Tube Heat Exchanger with Plate Fin (판형 핀을 가진 원통-다관형 열교환기의 열전달 특성에 관한 연구)

  • Lim, Tae-Woo;Cho, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.46-51
    • /
    • 2009
  • In this work, the experimental investigation was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the overall heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat transfer coefficients in shell side of heat exchanger with 9 plate finned tubes showed averagely 1.8 times and 2.3 times higher than those of 13 and 19 tubes, respectively.

Mechanical behaviour between adjacent cracks in CFRP plate reinforced RC slabs

  • Yuan, Xin;Bai, Hongyu;Sun, Chen;Li, Qinqing;Song, Yanfeng
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.375-391
    • /
    • 2022
  • This paper discussed and analyzed the interfacial stress distribution characteristic of adjacent cracks in Carbon Fiber Reinforced Polymer (CFRP) plate strengthened concrete slabs. One un-strengthened concrete test beam and four CFRP plate-strengthened concrete test beams were designed to carry out four-point flexural tests. The test data shows that the interfacial shear stress between the interface of CFRP plate and concrete can effectively reduce the crack shrinkage of the tensile concrete and reduces the width of crack. The maximum main crack flexural height in pure bending section of the strengthened specimen is smaller than that of the un-strengthened specimen, the CFRP plate improves the rigidity of specimens without brittle failure. The average ultimate bearing capacity of the CFRP-strengthened specimens was increased by 64.3% compared to that without CFRP-strengthen. This indicites that CFRP enhancement measures can effectively improve the ultimate bearing capacity and delay the occurrence of debonding damage. Based on the derivation of mechanical analysis model, the calculation formula of interfacial shear stress between adjacent cracks is proposed. The distributions characteristics of interfacial shear stress between certain crack widths were given. In the intermediate cracking region of pure bending sections, the length of the interfacial softening near the mid-span cracking position gradually increases as the load increases. The CFRP-concrete interface debonding capacity with the larger adjacent crack spacing is lower than that with the smaller adjacent crack spacing. The theoretical calculation results of interfacial bonding shear stress between adjacent cracks have good agreement with the experimental results. The interfacial debonding failure between adjacent cracks in the intermediate cracking region was mainly caused by the root of the main crack. The larger the spacing between adjacent cracks exists, the easier the interfacial debonding failure occurs.