• Title/Summary/Keyword: plate and frame module

Search Result 23, Processing Time 0.02 seconds

A Study on the Dynamic Characteristics of Door Module Plate (도어 모듈 플레이트의 동특성 분석에 관한 연구)

  • Bae, Chul-Yong;Kim, Wan-Su;Kim, Chan-Jung;Lee, Bong-Hyun;Jang, Woon-Sung;Mo, Yu-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.918-923
    • /
    • 2007
  • Currently, automotive industries improve the vehicle performance and reduce the development period of vehicle using each module part for the high quality and performance of vehicles. However each component part doesn't generate the noise and vibration problems, sometime these problems are generated on the assembly status between vehicle chassis frame and each module part. On this study, in order to analysis the dynamic characteristics of a shield door module that is a typical module part of vehicles, the acquisition and evaluation process about the vibration and noise of shield door module is developed. Also the possibility to apply to shield door module of the developed process is verified by the comparison with the dynamic characteristics between plastic and steel module plate.

  • PDF

Performance Analysis of Plate-and-Frame Forward Osmosis Membrane Module for Concentrating High Salinity Wastewater (고염도 폐수 농축을 위한 평판형 정삼투막 모듈의 성능 분석)

  • Kim, Yu Chang;Lee, Sungyun;Park, Sang-Jin;Kim, Han Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.6
    • /
    • pp.68-74
    • /
    • 2016
  • Hydraulic fracturing of wells during oil and gas (O&G) exploration consumes large volumes of fresh water and generates larger volumes of contaminated wastewater with high salinity. It is critical to treat and reuse the O&G wastewater in a cost-effective and environmentally sound manner for sustainable industrial development and for meeting stringent regulations. Recently, forward osmosis (FO) has been examined if it is a promising solution for treatment and desalination of complex industrial streams and especially fracturing flowback and produced waters. In the present study, the performances of a plate-and-frame FO membrane element and a module (6 elements combined in series) were investigated for concentrating high TDS wastewater. An FO module has achieved up to 64 % water recovery (i.e., concentration factor of 2.76) from 10,000 ppm wastewaters and can concentrate feed streams salinities to greater than 30,500 ppm.

Permeation Characteristics of the Plate & Frame Membrane Module with Protuberances (돌기형 평판 분리막 모듈의 투과특성)

  • Chung, Kun-Yong;Jeon, Sung-Il
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.168-175
    • /
    • 2008
  • This study was carried out for the plate and frame membrane modules equipped with and without plastic protuberances on the support frame in order to determine the effect of eddy flow induced by the protuberances on permeate flux. The initial time for rapidly declined permeate flux on the module with protuberances was delayed twice or more than that on the module without protuberances when kaolin solution was permeated at the operating pressures from 0.4 to 1.6 bar. Also decreasing ratio of the kaolin solution to pure water flux for module with protuberances was 1 to 5% lower than that for module without protuberances. The flux improvement due to protuberances at laminar flow corresponding Reynolds number 1,750 was about double as compared with that in the transition flow region. In general, the kaolin fouling reduction for the plate module with protuberances during initial filtration process was very effective, even though the permeate flux after 60 minutes filtration did not increase significantly.

Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module (평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향)

  • Kim, Sun-Il;Lee, Bong-Woo;Yun, Young-Jae
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF

A Study on the Dynamic Characteristics of Door Module Plate (도어 모듈 플레이트의 동특성 분석에 관한 연구)

  • Bae, Chul-Yong;Kim, Wan-Su;Kim, Chan-Jung;Lee, Bong-Hyun;Jang, Woon-Sung;Mo, Yu-Chul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.853-861
    • /
    • 2007
  • Currently, automotive industries improve the vehicle performance and reduce the development period of vehicle using each module part for the high quality and performance of vehicles. However each component part doesn't generate the noise and vibration problems, sometime these problems are generated on the assembly status between vehicle chassis frame and each module part. On this study, in order to analysis the dynamic characteristics of a shield door module that is a typical module part of vehicles, the acquisition and evaluation process about the vibration and noise of shield door module is developed. Also the possibility to apply to shield door module of the developed process is verified by the comparison with the dynamic characteristics between plastic and steel module plate.

Application of Reverse Osmosis Plate and Frame Type for Separation and Concentration Heavy Metal[Cu(II), Zn(II)] (중금속[Cu(II), Zn(II)]의 분리 및 농축을 위한 역삼투 판틀형 모듈의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek;Kim, Jong-Pal
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.307-312
    • /
    • 2004
  • This study was focused on experiment for the separation and concentration process of Cu(II), Zn(II) solution with the variation of applied pressure and concentration using reverse osmosis plate and frame modules. Rejection coefficient and degree of concentration for Cu(II) component using single and multi-stage reverse osmosis process were showed 96.3~97.8%, 0.044~0.191(in single-stage), 96.3~98.4%, 0.400~2.264(in multi-stage) within the range of experimental condition, respectively. Those of Zn(II) were 93.3~97.1%, 0.019~0.395(in single-stage), 96.3~98.2%, 0.365~1.454(in multi-stage), respectively. Degree of concentration of multi-stage were higher than those of single-stage. Heavy metal[Cu(II), Zn(II)] separation was very efficient in using reverse osmosis plate and frame type modules. Separation efficiency for a mixed solution Cu(II) and Zn(II) was higher than those of each one of Cu(II) and Zn(II).

Modeling of Pervaporation Process: Prediction of Feed Temperature Distribution in A Frame and Plate Type of Membrane Module (판틀형 투과증발 막모듈내에서 feed 온도 분포 예측을 위한 모델링)

  • 원장묵;염충균;임지원;배성렬;하백현
    • Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.44-52
    • /
    • 1996
  • For the purpose of the optimal design of a frame and plate type of pervaporation module, model equations which can predict the effects of feed flow condition on the temperature distribution of the feed developed in the module were established and the temperature distribution with feed flow condition was investigated through the model si$$\mu$ation. With increasing the Reynolds number of feed flow in the module, the flow velocity gradient in the channel height-direction as well as the volume rate of feed which acts as energy source for the evaporation of perrneants on the permeate-side surface of a membrane increased to such an extent that both mass and heat flux in the channel height direction could increase and the temperature drop of feed due to the evaporation of the permeant could be reduced correspondingly. A decrease in channel height caused the temperature drop of feed because of decreasing feed flow in the module. It was observed that the si$$\mu$ation result on the effect of Re on the temperature distribution of feed in the module has an agreement with experiment.

  • PDF

Development of Pervaporation Module and Modelling of Feed Temperature Distribution in A Frame and Plate Type of Membrane Module (투과증발 막모듈의 개발과 판틀형 모듈 내에서의 온도 감소 현상에 관한 모델링)

  • 임지원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.03a
    • /
    • pp.111-125
    • /
    • 1996
  • 본 연구에서는 평판형 모듈 설계의 최적화를 목적으로 원액 흐름 조건에 따른 모듈내 원액 온도 및 유속 분포를 예측할 수 있는 모델식을 확립하고 전산모사(simulation)를 통해 흐름 조건들이 온도 분포에 끼치는 영향들을 조사하였으며 이들의 결과를 모듈설계에 반영하고자 하였다. 확립된 모델식의 타당성을 확인하기 위하여 최소한의 실험을 행하여 실험치와 모델치를 비교하였다. 또한 개발된 새로운 구조를 지니는 평판형 막모듈에 상용화된 막과 국내에서 개발된 막을 장착하여 모듈 내에서의 온도감소 현상을 실험적으로 비교하였다.

  • PDF

Analysis of the Separation Using Disc Plate and Frame Type Reverse Osmosis Module (원판틀형 역삼투 모듈을 이용한 분리 특성 해석)

  • Chung, Kun-Yong;Chung, Wook;Won, Jang-Mook;Bae, Seong-Youl;Ha, Baik-Hyon
    • Membrane Journal
    • /
    • v.5 no.2
    • /
    • pp.81-88
    • /
    • 1995
  • Separation performance was measured for the disc plate and frame type reverse osmosis module using NaCl and sucrose solutions. An analysis of membrane performance was done following the equations proposed by Kimura-Sourirajan[8]. The membrane permeability was $2.17 \times 10^{-6}$(gmol/$cm^2$-sec-bar) and independent of operating pressure. The effect of concentration polarization for sucrose solution was higher than that of NaCl. Permeation flux for sucrose solution above 40 bar was decreased as operating pressure was increased. Solute rejection for NaCl solution was decreased, but that of sucrose was increased as operating pressure was increased.

  • PDF