• Title/Summary/Keyword: plate anchors

Search Result 45, Processing Time 0.025 seconds

Experimental evaluation of back-to-back anchored walls by double-plates anchors

  • Amir, Najafizadeh;AmirAli, Zad
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp.599-614
    • /
    • 2022
  • One of the methods of stabilizing retaining walls, embankments, and deep excavations is the implementation of plate anchors (like the Geolock wall anchor systems). Back-to-back Mechanically Stabilized Earth (BBMSE) walls are common stabilized earth structures that can be used for bridge ramps. But so far, the analysis of the interactive behavior of two back-to-back anchored walls (BBAW) by double-plates anchors (constructed closely from each other and subjected to the limited-breadth vertical loading) including interference of their failure and sliding surfaces has not been the subject of comprehensive studies. Indeed, in this compound system, the interaction of sliding wedges of these two back-to-back walls considering the shear failure wedge of the foundation, significantly impresses on the foundation bearing capacity, adjacent walls displacements and deformations, and their stability. In this study, the effect of horizontal distance between two walls (W), breadth of loading plate (B), and position of vertical loading was investigated experimentally. In addition, the comparison of using single and equivalent double-plate anchors was evaluated. The loading plate bearing capacity and displacements, and deformations of BBAW were measured and the results are presented. To evaluate the shape, form, and how the critical failure surfaces of the soil behind the walls and beneath the foundation intersect with one another, the Particle Image Velocimetry (PIV) technique was applied. The experimental tests results showed that in this composite system (two adjacent-loaded BBAW) the effective distance of walls is about W = 2.5*H (H: height of walls) and the foundation effective breadth is about B = H, concerning foundation bearing capacity, walls horizontal displacements and their deformations. For more amounts of W and B, the foundation and walls can be designed and analyzed individually. Besides, in this compound system, the foundation bearing capacity is an exponential function of the System Geometry Variable (SGV) whereas walls displacements are a quadratic function of it. Finally, as an important achievement, doubling the plates of anchors can facilitate using concrete walls, which have limitations in tolerating curvature.

Analytical and Experimental Studies on Partially Composite of Steel-Plate Girder Bridges Using Slab Anchors (바닥판 앵커를 사용한 플레이트거더교의 부분합성에 관한 해석 및 실험 연구)

  • Han, Sang Yun;Park, Nam Hoi;Yoon, Ki Young;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.325-332
    • /
    • 2004
  • Cross sections of steel-plate girder bridges are divided into three cross sections of non-composite, partially composite, and fully composite sections, according to their composite characteristics. The Korean provision for the partially and fully composite sections specifies general usage of the stud of shear connectors, whereas the one for the non-composite section specifies empirical usage of slab anchors. However, the actual behavior of the cross sections of steel-plate girder bridges using slab anchors is close not to the non-composite action, but to the partially composite action. Therefore analytical and experimental studies on partial composites of steel-plate girder bridges using slab anchors are performed in this study. Intial stiffness of the slab anchor is obtained by the experimental study for the first time, and the composite characteristic of simple-span and two-span continuous steel-plate girder bridges is investigated by the finite element analyses for the second time. Based on the obtained initial stiffness, the reduction effect of tensile stresses in the concrete-slab on the intermediate support of the continuous bridge is also considered herein.

A Study on the Characteristics of Creep in Kaolinite Soil Subjected to Uplift Capacity (인발력을 받는 Kaolinite 지반의 장기변위 특성에 관한 연구)

  • 이준대;최기봉
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.116-121
    • /
    • 1999
  • When plate anchors are embedded in soft clay, they may undergo a deformation under the pressure of sustained load. The critical depth at which the transition from a shallow to a deep anchor takes place depends on the properties of soil. Laboratory model tests were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated kaolinite. The tests have been conducted with the anchor at two different moisture contents. Based on the model test results, empirical relationships between the net load, rate of strain, and time have been developed. In creep tests of kaolinite for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time.

  • PDF

Suction Effect during Pullout of Anchors in Clay (점성토에 근입된 앵커들의 상향 인발시 흡입효과)

  • Shin, Bang Woong;Shin, Eun Chul;Lee, Jun Dae;Das, Braja M.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1433-1438
    • /
    • 1994
  • Laboratory model test results for uplift capacity of a circular plate anchors embedded in saturated clayey soils have been presented. Clayey soils used in this study are kaolinite and montmorillonite. Suction effects on the ultimate uplift capacity of plate anchors with respect to various embedment depths of anchor have been considered.

  • PDF

Uplift Capacity of a Plate Anchor Considering Suction Effects

  • Seo, Young-Kyo;Kim, Tae-Hyung
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2008
  • Anchors have been commonly used to as foundation systems of the structures that require the uplift resistance. Recently anchors have been used in ocean sediment for mooring systems to stabilizeoffshore structures. In the saturated clayey soil however suction developed between the soil and andchor and affects the uplift capacity of anchor. To estimate the uplift capacity of the andchor accurately, the failure mechanisms of the andchor by the uplift force should also be correctly assumed. The uplift capacity is usually expressed in terms of breakout factors with respect to embedment ratio. In this paper, a two-dimensional plane strain numerical investigation into the vertical uplift capacity of a plate andchor in a clayey soil is described. The breakout factor against their corresponding values of embedment ratio was calculated and plotted along a single curve. The modes of failure mechanism at shallow and deep andchors are also presented.

Strengthening method against Overturn of Plain Concrete Gravity Pier for Open-Steel-Plate-Girder Railway Bridges (철도판형교 무근콘크리트 교각의 전도 보강기법)

  • Lee, Jun-S.;Choi, Eun-Soo;Rhee, In-Kuy;Lee, Joo-B.
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1165-1173
    • /
    • 2007
  • Open-Steel-Plate-Girder railway bridges, in general, have plain concrete gravity pier without piles at foundations. Such piers are vulnerable to be overturned against braking forces and ground shakings during an earthquake. Thus, this study suggests a strengthening method using earth anchors to improve the resistance of plain concrete gravity piers to the overturn of themselves. Also, a filed test was performed for the as-built and the strengthened pier and the test results were compared to assess the strengthening effect. The earth anchors increased the ultimated capacity for the pier's overturn. Finally, a FE analysis was conducted using nonlinear elements for soil to understand the distribution of the soil stresses for the as-built and the strengthened pier.

  • PDF

Pullout capacity of vertical plate anchors in cohesion-less soil

  • Kame, G.S.;Dewaikar, D.M.;Choudhury, Deepankar
    • Geomechanics and Engineering
    • /
    • v.4 no.2
    • /
    • pp.105-120
    • /
    • 2012
  • In this paper, the ultimate pullout capacity of a vertical plate strip anchors in cohesion-less soil is analyzed with the consideration of active and passive state of equilibrium in the soil. K$\ddot{o}$tter's equation is used to compute the active and passive thrusts (along with their point of application) which are subsequently used in the analysis in which, all the equation of equilibrium are properly interpreted. A comparison of the results with the experimental results vis-$\grave{a}$-vis available theoretical/empirical solutions shows that, the proposed analysis provides a better estimate of the pullout capacity.

Strengthening of reinforced concrete beams with epoxy-bonded perforated steel plates

  • Aykac, Sabahattin;Kalkan, Ilker;Uysal, Ali
    • Structural Engineering and Mechanics
    • /
    • v.44 no.6
    • /
    • pp.735-751
    • /
    • 2012
  • Although being one of the most popular strengthening techniques in reinforced concrete beams, the use of steel plates bonded to the soffit raises problems of ductility. This study aims at investigating the influence of the use of perforated steel plates instead of solid steel plates on the ductility of reinforced concrete beams. A total of nine reinforced concrete beams were tested. In addition to an unplated beam, eight beams with perforated steel plates of two different thicknesses (3 mm and 6 mm) were subjected to monotonic loading. Effect of bonding the plates to the beams with anchor bolts and with additional side plates bonded to the sides of the beam with and without anchors is also investigated. The use of bolts in addition to epoxy was found to greatly contribute to the ductility and energy absorption capacity of the beams, particularly in specimens with thick plates (6 mm) and the use side plates in addition to the bottom plate was found to be ineffective in increasing the ductility of a concrete beam unless the side plates are attached to the beam with anchors bolts. The thickness of the plate was found to have little effect on the bending rigidity of the beam.

Flexural Strengthening Effects of RC Beam Reinforced with Pre-stressing Plate (긴장을 가한 보강 플레이트로 보강된 RC 보의 휨보강 효과)

  • Ha, Sang-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.171-178
    • /
    • 2019
  • Fiber-reinforced polymer (FRP) composites have proved to be reliable as strengthening materials. Most of existing studies used single types of FRP composites. Therefore, in this experimental study, carbon FRP sheet, aramid FRP sheet, and hybrid FRP plate including glass fibers were fabricated, and the effect of pre-stressed FRP composites on flexural strengthening of reinforced concrete (RC) beams was investigated. In total, eight RC beam specimens were fabricated, including one control beam (specimen N) without FRP composites and seven FRP-strengthened beams. The main parameters were type of FRP composite, the number of anchors used for pre-stressing, and thickness of FRP plates. As a result, the beam strengthened with pre-stressed FRP plate showed superior performance to the non-strengthened one in terms of initial strength, strength and stiffness at yielding, and ultimate strength. As the number of anchors and thickness of FRP plate (i.e., amount of FRP plates) increased, the strengthening effect increased as well. When hybrid FRP plates were pre-stressed, the strengthening effect was higher in comparison with pre-stressed single type FRP plate.

Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam (절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • Based on U-shaped composite beam, the new form of AU-composite beam were developed to create economical and efficient components reducing the cost and shortening the length of construction work. Because the U-shaped sections are open and needs to be fixed by topping concrete securely. Therefore, it is required to maintain the U-shaped sections in a structure and to work in the safe condition through construction. It also requires accessories that resist the horizontal shear force for synthesis between the top and bottom of the U-shaped section. To reinforce these shortcomings, a shear connector has been developed with various purposes of steel plate anchors. In this study, the steel plate anchors were directly tested and the shear force was evaluated by the horizontal shear force. The experiment was divided into two types, depending on the applicable deck plates. As a result of the experiment, the continuous type specimens showed greater resistance in both strength and displacement than the ones of stud anchor specimen. In discontinuous type case, due to shear simulations and simple element analysis, the less increase the ratio of width to height and the more shear strength decreased. Thus, the shear strength equation of the stud anchor was modified to suggest the new shear strength based on the testing results.