• 제목/요약/키워드: plastic range

검색결과 1,093건 처리시간 0.021초

CR60강, SM58Q강과 그 용접부의 저사이클 피로특성 (A Study of Low Cycle Fatigue Properties in CR60,SM50Q Steel and the Weldments)

  • 김창주;염태동;유인석;위창욱
    • Journal of Welding and Joining
    • /
    • 제12권1호
    • /
    • pp.73-79
    • /
    • 1994
  • Low cycle fatigue test was performed by companion specimens method to compare the properties of cyclic strain for the weldments of controlled rolling steel CR60 and welding structural steel SM58Q. And the result does not showed any difference of low cycle fatigue life between weldments. Especially, the values of coefficient of cyclic plastic strain $C_{p}$ and exponent of cyclic plastic strain $K_{p}$ of heat affected zones of CR60 steel and SM58Q steel were same. And $C_{p}$ and $K_{p}$ of CR60 steel were equal to the values of weld it means a good combination between the base metal, the heat affected zone and the weld of CR60 steel.eel.eel.

  • PDF

Meshed Acellular Dermal Matrix for Two-Staged Prepectoral Breast Reconstruction: An Institutional Experience

  • Luo, Jessica;Willis, Rhett N. Jr;Ohlsen, Suzanna M.;Piccinin, Meghan;Moores, Neal;Kwok, Alvin C.;Agarwal, Jayant P.
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.166-173
    • /
    • 2022
  • The introduction of acellular dermal matrix (ADM) to breast reconstruction has allowed surgeons to reexplore the prepectoral implant placement technique in postmastectomy breast reconstruction. Our institution adopted a novel approach using meshed ADM to lessen the financial burden of increased ADM utilization with the prepectoral breast reconstruction. This is a retrospective, single-center review of two-stage prepectoral breast reconstruction using meshed human-derived ADM for anterior prosthesis coverage. Patient demographics, oncologic data, perioperative characteristics, and complications were examined and reported as means with standard deviations. Cost-saving with the meshed technique was evaluated. Forty-eight patients (72 breasts) with a mean age of 48.5 ± 15.0 years (range 26-70 years) were included in the study. The mean follow-up time was 13.2 ± 4.4 months (range 4.1-25.8 months). Nineteen breasts (24.6%) experienced complications, with seromas being the most common complication (12.5%, n = 9). Expander removal and reoperation occurred at a rate of 8.3 and 9.7%, respectively. The average time to drain removal was 18.8 ± 6.6 days (range 8-32 days). Meshed ADM provided an average cost savings of $6,601 for unilateral and $13,202 for bilateral reconstructions. Our study found that human-derived meshed ADM can be safely used in two-staged prepectoral tissue expander-based breast reconstruction and can result in significant cost savings.

알로덤이 건 봉합술 후 발생되는 유착 방지에 미치는 효과 (The Effect of Alloderm on Prevention of Adhesions following Tenorrhaphy in the Rabbits)

  • 최창용;송진우;김준혁;최환준;이영만
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.765-770
    • /
    • 2007
  • Purpose: Peritendinous adhesion is one of the most notorious complication after the flexor tendon injury. In this study, $Alloderm^{(R)}$(LifeCell Corp., Branchburg, N.J.), which is the decellularized human dermal analogue with its intact native basement membrane components, was used for the prevention of peritendinous adhesions following flexor tendon repair. Methods: Thirty New Zealand white male rabbits were divided equally into 3 groups. In all groups, the flexor digitorum profundus of the third finger of the right back foot was cut totally and repaired by modified Kessler suture technique. Following tendon repair, $Alloderm^{(R)}$ was wrapt around the repaired tendon in the first group and sodium hyaluronate gel was sprayed to the operation field in the second group. In the control group, no external material was applied. The right back foot were immobilized for 6 weeks to optimize the formation of adhesion ingrowth. After death, the third finger that repaired tendons and sheaths was removed en bloc. We checked range of motion. and studied histologically for all groups. Results: The experimental groups had better range of motion than the control group. We checked that the range of motion was 73.5 degrees in $Alloderm^{(R)}$ group, 55.9 degrees in the hyaluronic acid group, and 38.3 degrees in the control group. in the histological study, the experimental group had less adhesions compared with the control group. Conclusion: This study concludes that $Alloderm^{(R)}$ can decrease peritendinous adhesions following flexor tendon repairs in rabbits. We think the method could be used in clinical cases.

Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population

  • Lee, Yoon Jae;Kim, SeongAe;Lee, Jisung;Chung, Joong Geel;Jun, Young Joon
    • Archives of Plastic Surgery
    • /
    • 제47권2호
    • /
    • pp.171-177
    • /
    • 2020
  • Background Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors' experience over a 3-year period is presented and reviewed. Methods A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. Results From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5-3.5 years). The mean skin excision height and width were 9.75 mm (range, 5-16 mm) and 58.51 mm (range, 42-75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. Conclusions The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding.

플라스틱성형용 KP-4M강의 마멸특성 및 이의 기구에 관한 연구 (A Study on the Wear Characteristics and the Mechanism of KP-4M Steel for Plastic Molding)

  • 박흥식;전태옥;김동호
    • Tribology and Lubricants
    • /
    • 제12권1호
    • /
    • pp.22-28
    • /
    • 1996
  • This study was undertaken to investigate the dry wear characteristics and mechanism of KP-4M steel for plastic molding against SKD 61 hardened by heat treatment. The wear test was carried out under different conditions such as sliding speed, contact pressure, sliding distance, with frictional tester of pin on disc type. The wear loss on variation of sliding speed was little in lower speed range below 0.5 m/sec and in higher speed range above 1.5 m/sec,'but wear loss was high in intermediate speed range. The critical sliding speed, which showed the maximum value of specific wear rate, became lower with increased contact pressure. Increasing the contact pressure, the critical sliding distance Lcr which the wear mechanism changes from severe wear to mild wear was increased due to the decrease of oxidation reaction velocity. Through this study we suggested a model of generation and elimination process of wear debris of KP-4M steel for plastic molding.

Partially confined circular members subjected to axial compression: Analysis of concrete confined by steel ties

  • Eid, R.;Dancygier, A.N.
    • Structural Engineering and Mechanics
    • /
    • 제21권6호
    • /
    • pp.737-765
    • /
    • 2005
  • This paper presents a theoretical model for the behavior of partially confined axi-symmetric reinforced concrete members subjected to axial load. The analysis uses the theories of elasticity and plasticity to cover the full range of the concrete behavior. Analysis of the elastic range of the problem involves boundary conditions that are defined along a relatively simple geometry. However, extending the analysis into the plastic range involves difficulties that arise from the irregular geometry of the boundary between the plastic zone and the elastic zone, a boundary which is also changing as the axial load increases. The solution is derived by replacing the discrete steel ties with an equivalent tube of thickness $t_{eq}$ and by analyzing the concrete cylinder, which is uniformly confined by the equivalent tube. The equivalency criterion initiates from a theoretical analysis of the problem in its elastic range where further finite element analysis shows that this criterion is valid also for the plastic range of the cylinder material. According to the proposed model, the efficiency of the lateral reinforcement can be evaluated by the equivalent thickness $t_{eq}$. Comparison with published test results of confined reinforced concrete stress-strain curves shows good agreement between the test and the analytical results.

Epidemiology of severe trauma patients treated by plastic surgeons: A 7-year study at a single regional trauma center in South Korea

  • Jung, Joo Sung;Kang, Dong Hee;Lim, Nam Kyu
    • Archives of Plastic Surgery
    • /
    • 제47권3호
    • /
    • pp.223-227
    • /
    • 2020
  • Background After the laws regulating emergency medicine were amended in 2012, regional trauma centers were established in South Korea. Plastic surgeons specialize in the simultaneous surgical care of patients with facial trauma, burns, and complicated wounds. The objective of this study was to evaluate the role of the plastic surgery department in treating severe trauma patients. Methods From January 2012 to December 2018, we enrolled 366 severe trauma patients with an Injury Severity Score (ISS) over 15 who received treatment by specialists in the plastic surgery department. Of these patients, 298 (81.4%) were male, and their mean age was 51.35 years (range, 6-91 years). The average ISS was 22.01 points (range, 16-75 points). Results The most common diagnosis was facial trauma (95.1%), and facial bone fracture (65.9%) was most common injury within this subgroup. Patients were referred to 1.8 departments on average, with the neurosurgery department accounting for a high proportion of collaborations (37.0%). The most common cause of trauma was traffic accidents (62.3%), and the average length of stay in the general ward and intensive care unit was 36.90 and 8.01 days, respectively. Most patients were discharged home (62.0%) without additional transfer or readmission. Conclusions Through this study, we scoped out the role of the specialty of plastic surgery in the multidisciplinary team at regional trauma centers. These results may have implications for trauma system planning.

Sensory assessment of meshed skin grafts over free gracilis muscle flaps without nerve coaptation for lower extremity reconstruction

  • Tremp, Mathias;Waldkircher, Natascha J.;Wang, Wenjin;Oranges, Carlo M.;di Summa, Pietro G.;Zhang, Yixin;Wang, Wei;Schaefer, Dirk J.;Kalbermatten, Daniel F.
    • Archives of Plastic Surgery
    • /
    • 제48권2호
    • /
    • pp.224-230
    • /
    • 2021
  • Background Little is known about the sensate recovery of skin grafts over free non-neurotized muscle flaps. The aim of this study was to evaluate the sensitivity of free gracilis muscle flaps and meshed skin grafts without nerve coaptation. Methods Thirteen consecutive patients with a median age of 55 years (range, 21-70 years) who underwent lower extremity reconstruction between September 2014 and October 2016 were included. Complications, flap contour, skin perception, and sensate recovery were assessed. Results All flaps survived completely. In one patient, wound dehiscence and infection occurred 1 month after surgery. After a median follow-up of 14 months (range, 10-51 months), a satisfactory contour and skin perception were achieved. The Semmes-Weinstein (SW) monofilament test (154.8±22 g) and static two-point discrimination (2-PD) (12.6±0.7 mm) showed intermediate recovery compared to the surrounding site (41% and 76%, respectively). There was an intermediate correlation between flap size and sensate recovery (2-PD: r=0.27, P=0.36; SW test: r=0.45, P=0.12). Vibration sensation recovered to 60%, whereas thermal sensation remained poor (19% at 5℃ and 25% at 25℃). Conclusions Finer sensation could be partially restored. However, thermal sensation remained poor.