• Title/Summary/Keyword: plasma in liquid

Search Result 614, Processing Time 0.039 seconds

Bioequivalence of MelaxTM Capsule to MobicTM Capsule (Meloxicam 7.5 mg) (모빅 캡슐(멜록시캄 7.5 mg)에 대한 멜락스 캡슐의 생물학적동등성)

  • Lee, Ye-Rie;Yeom, Seung-Bock;Ko, Youn-Jung;Ko, Jung-Kil;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.413-418
    • /
    • 2004
  • A bioequivalence of $Melax^{TM}$ capsules (Chong Kun Dang Pharm., Korea) and $Mobic^{TM}$ capsules (Boehringer Ingelheim Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 15 mg dose of meloxicam of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2\;{\times}\;2$ crossover design. Concentrations of meloxicam in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 72 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Melax^{TM}/Mobic^{TM}$ were 0.95 - 1.04 and 0.98 - 1.14, respectively. This study demonstrated a bioequivalence of $Melax^{TM}$ and $Mobic^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of PirosTM Tablets to ActosTM Tablets (Pioglitazone HCl 15 mg) (액토스TM정(염산 피오글리타존 15 mg)에 대한 피로스TM정의 생물학적 동등성)

  • Kang, Jong-Min;Lee, Myung-Jae;Seo, Ji-Hyung;Choi, Sang-Jun;Lee, Jin-Sung;Ryu, Ju-Hee;Tak, Sung-Kwon;Yim, Sung-Vin;Hong, Seung-Jae;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • The purpose of the present study was to evaluate the bioequivalence of two pioglitazone HCl tablets, $Actos^{TM}$, tablets (Lilly Korea. Ltd., Korea) as a reference drug and $Piros^{TM}$, tablets (Reyon Pharm. Co., Ltd., Korea) as test drug, according to the guideline of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received one tablet containing pioglitazone HCl 15 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of pioglitazone were monitored for over a period of 36 hr after administration by using a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The area under the plasma concentration-time curve from time zero to 36 hr ($AUC_{0-36hr}$), maximum plasma drug concentration ($C_{max}$) and time to reach $C_{max}$ ($T_{max}$) were complied from the plasma concentration-time data. Analysis of variance (ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_{0-36hr}$ and $C_{max}$. The 90% confidence intervals of the $AUC_{0-36hr}$ ratio and the $C_{max}$ ratio for $Piros^{TM}$/$Actos^{TM}$. were log 0.8753-log 1.1286 and log 0.8669-log 1.1734, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25, recommended by KFDA. In all of these results, we concluded that the $Piros^{TM}$. tablet was bioequivalent to the $Actos^{TM}$. tablet, based on the rate and extent of absorption.

Bioequivalence of MeloxifenTM Capsule to MobicTM Capsule(Meloxicam 7.5 mg) (모빅캡슐(멜록시캄 7.5mg)에 대한 멜록시펜캡슐의 생물학적 동등성)

  • Lee, Jin-Sung;Tak, Sung-Kwon;Seo, Ji-Hyung;Kang, Jong-Min;Ryu, Ju-Hee;Yim, Sung-Vin;Hong, Seung-Jae;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.457-463
    • /
    • 2009
  • The purpose of the present study was to evaluate the bioequivalence of meloxicam capsule, $Mobic^{TM}$ capsule( Boehringer Ingelheim Ltd., Korea) as a reference drug and $Meloxifen^{TM}$ capsule (Kukje Pharma Ind. Co., Ltd., Korea) as a test drug, according to the guidelines of Korea Food and Drug Administration(KFDA). Thirty two healthy male Korean volunteers received capsule containing meloxicam 7.5 mg in a $2{\times}2$ crossover study. There was a one-week above washout period between the doses. Plasma concentrations of meloxicam were monitored for over a period of 72 hr after administration by using a high performance liquid chromatography-tandem mass spectrometer(LC-MS/MS). $AUC_t$(the area under the plasma concentration-time curve from time zero to 72 hr), $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were complied from the plasma concentration-time data. Analysis of variance(ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Meloxifen^{TM}/Mobic^{TM}$ were log 0.8605-log 0.9847 and log 0.9765-log 1.1503, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25, recommended by KFDA. In all of these results, we concluded that $Meloxifen^{TM}$ capsule was bioequivalent to $Mobic^{TM}$ capsule, based on the rate and extent of absorption.

Bioequivalence of LANIDIEM® Tablet 4 mg to Vaxar® Tablet 4 mg(Lacidipine 4 mg) (박사르®정 4 밀리그램(라시디핀 4 mg)에 대한 라니디엠®정 4 밀리그램의 생물학적동등성)

  • Lee, Yun-Young;Kim, Hye-Jin;La, Sookie;Cho, Kyung-Hee;Jang, Moon-Sun;Park, Young-Joon;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • A bioequivalence study of LANIDIEM$^{(R)}$ tablet 4 mg (Samil. Co., Ltd.) to Vaxar$^{(R)}$ tablet 4 mg (GlaxoSmithKline Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Forty healthy male Korean volunteers were enrolled in the study and thirty six volunteers completed the study according to the protocol. Thirty six volunteers received each medicine at the lacidipine dose of 4 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of lacidipine were monitored by a high performance liquid chromatography - tandem mass spectrometry (LC-MS/MS) for over a period of 24 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for LANIDIEM$^{(R)}$/Vaxar$^{(R)}$ were log 0.8102~log 1.0417 and log 0.8493~log 1.1439, respectively. These values were within the acceptable bioequivalence intervals of log 0.80~log 1.25. Thus, our study demonstrated the bioequivalence of LANIDIEM$^{(R)}$ tablet 4 mg and Vaxar$^{(R)}$ tablet 4 mg with respect to the rate and extent of absorption.

A STUDY OF MONOMER RELEASE FROM PIT AND FISSURE SEALANTS ACCORDING TO VARIOUS LIGHT SOURCES (광원에 따른 수종의 치면열구전색제로부터 용리되는 모노머에 관한 연구)

  • Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.284-292
    • /
    • 2005
  • The aim of this study was to identify and quantify the major or detectable monomers released from any of five commercially-available, light-cured pit and fissure sealants with three different light sources : conventional halogen light curing unit, plasma arc light curing unit and LED curing unit. After curing, specimens were immediately immersed in distilled water for different time intervals. The time related release of monomers were analyzed by high performance liquid chromatography(HPLC). Identification and quantitative analysis of monomers were performed by the comparison of the elution time and the absorption peak height of the eluates with those of the authentic sample. The result of this study can be summarized as follows. 1. Standard solution peaks with retention times of 2.3, 3.2, 5.6, 6.5, 10.4 minutes were identified as BPA, TEGDMA, UDMA, Bis-GMA, Bis-DMA, respectively. 2. None of the chromatograms of the tested sealants displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 3. The highest release rate of TEGDMA was observed during the 12hr period for all samples and declined thereafter. 4. The elution of TEGDMA from curing with Halogen curing unit for 20 second and LED for 10 second was less than that resulting from curing with Plasma arc for 3 second. 5. TEGDMA was detected at much lower levels in eluates from the Pit & Fissure $Sealant^{TM}$ than other sealants. The elution of TEGDMA from the $Helioseal^{(R)}$ F cured with Halogen light curing unit, the $Concise^{TM}$ cured with Plasma arc curing unit and the $Teethmate^{(R)}$ F-1 cured with LED curing unit were higher than other sealants.

  • PDF

Bioequivalence of EtodolTM Tablet to KuhnillodineTM Tablet (Micronized Etodolac 200 mg) (건일로딘 정(미결정에토돌락 200 mg)에 대한 에토돌 정의 생물학적동등성)

  • Lee, Jung-Ae;Lee, Yun-Young;Cho, Tae-Seob;Park, Young-Joon;Moon, Byoung-Seok;Kim, Ho-Hyun;Lee, Ye-Rie;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.4
    • /
    • pp.319-325
    • /
    • 2004
  • A bioequivalence of $Etodol^{TM}$ tablets (Yuhan corporation) and $Kuhnillodine^{TM}$ tablets (Kuhnil Pharm. Co., Ltd.) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 200 mg dose of etodolac of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2{\times}2$ crossover design. Concentrations of etodolac in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Etodol^{TM}/Kuhnillodine^{TM}$ were 1.01-1.10 and 0.87-1.06, respectively. This study demonstrated a bioequivalence of $Etodol^{TM}$ and $Kuhnillodine^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.

Effects of Storage in Different Commercial Semen Extenders on Sperm Motility, Viability and Membrane Integrity of Korean Native Boar Spermatozoa

  • Sa, Soo-Jin;Kim, In-Cheul;Choi, Sun-Ho;Hong, Joon-Ki;Kim, Du-Wan;Cho, Kyu-Ho;Kim, Young-Hwa;Chung, Ki-Hwa;Park, Jun-Cheol
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.349-353
    • /
    • 2013
  • The objective of this study was to compare the effect of semen extenders on the sperm motility, viability, acrosome integrity and functional integrity of plasma membrane (HOST: hypo-osmotic swelling test) during liquid preservation of Korean Native boar semen. In this experiment, semen was diluted in Androhep plus, Beltsville Thawing Solution (BTS), ModenaTM, Seminark and Vitasem LD. Sperm-rich fractions were collected from three Korean Native boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different semen extenders. Semen samples were stored at $17^{\circ}C$ for 96 hours. On everyday (0, 24, 48, 72, 96 h) after storage, the sperm characteristics relevant for fertility, such as sperm motility, viability, acrosome integrity and HOST positive were evaluated. The motility of spermatozoa stored in different extenders was no significantly different among other extenders (P>0.05). Also, no difference was observed among samples processed with different extenders in the percentage of sperm viability, acrosome integrity and HOST positive. All extenders maintained a high percentage (70%) of sperm motility, viability and acrosome integrity through 96 h of storage. The result of this study show that there was no significant differences among extenders in their capacity to preserve motility, viability and membrane integrity of spermatozoa from normal, fertile Korean Native boars for 96 h of liquid preservation at $17^{\circ}C$.

Effect of Heat Treatment on Interface Behavior in Ni-P/Cr Double Layer (열처리 시간에 따른 Ni-P/Cr 이중 도금 층의 계면 거동에 관한 연구)

  • Choi, Myung-Hee;Park, Young-Bae;Rhee, Byong-ho;Byon, Eungsun;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.260-268
    • /
    • 2015
  • The thermal barrier coating (TBC) for inner wall of liquid-fuel rocket combustor consists of NiCrAlY as bonding layer and $ZrO_2$ as a top layer. In most case, the plasma spray coating is used for TBC process and this process has inherent possibility of cracking due to large difference in thermal expansion coefficients among bonding layer, top layer and metal substrate. In this paper, we suggest crack-free TBC process by using a precise electrodeposition technique. Electrodeposited Ni-P/Cr double layer has similar thermal expansion coefficient to the Cu alloy substrate resulting in superior thermal barrier performance and high temperature oxidation resistance. We studied the effects of phosphorous concentrations (2.12 wt%, 6.97 wt%, and 10.53 wt%) on the annealing behavior ($750^{\circ}C$) of Ni-P samples and Cr double layered electrodeposits. Annealing temperature was simulated by combustion test condition. Also, we conducted SEM/EDS and XRD analysis for Ni-P/Cr samples. The results showed that the band layers between Ni-P and Cr are Ni and Cr, and has no formed with heat treatment. These band layers were solid solution of Cr and Ni which is formed by interdiffusion of both alloy elements. In addition, the P was not found in it. The thickness of band layer was increased with increasing annealing time. We expected that the band layer can improve the adhesion between Cr and Ni-P.

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF