• Title/Summary/Keyword: plasma in liquid

Search Result 614, Processing Time 0.032 seconds

Spray Coating Technology (스프레이 코팅 기술)

  • Lee, Chang-Hee
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.193-199
    • /
    • 2008
  • Spray coating is a versatile surface modification technology in which coating is built-up based on the successive deposition of micron-scaled particles. Depending on the coating materials, the coatings can meet the required mechanical properties, corrosion resistance, and other properties of base materials. Spraying processes are mainly classified into thermal and kinetic spraying according to their bonding mechanism and deposition characteristics. Specifically, thermal spraying process can be further classified into many categories based on the design and mechanism of the process, such as frame spraying, arc spraying, atmospheric plasma spraying (APS), and high velocity oxygen-fuel (HVOF) spraying, etc. Kinetic spraying or cold gas dynamic spraying is a newly emerging coating technique which is low-temperature and high-pressure coating process. In this paper, overall view of thermal and kinetic spray coating technologies is discussed in terms of fundamentals and industrial applications. The technological characteristics and bonding mechanism of each process are introduced. Deposition behavior and properties of technologically remarkable materials are reviewed. Furthermore, industrial applications of spray coating technology and its potentials are prospected.

  • PDF

Characteristics of Phosphors for PDP with Frit Contents (Frit 첨가량에 따른 PDP용 형광체의 특성 연구)

  • Jung, Ah-Reum;Kim, Hyeong-Jun;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.2
    • /
    • pp.146-150
    • /
    • 2010
  • Because the plasma display panel has used red, green and blue(RGB) phosphors, it has suffer from two intrinsic problems; 1) the cell defect due to the lack of binding force between phosphor particles and 2) mis-discharge because of difference of electrical characteristics among RGB phosphors. In order to control the mechanical and electrical properties of RGB phosphors, frit with $ZnOB_2O_3-SiO_2-Al_2O_3$ system was added to RGB phosphor as sintering additive. The mechanical properties were increased by the amount of frit. The amount of frit under 5 wt% rarely affected dielectric constant. However, there was the limit of amount because of decreasing optical properties seriously; over 3 wt% in red, over 10 wt% in green and blue.

Electrochemical Degradation of Benzoquinone in a Flow through Cell with Carbon Fibers

  • Yoon, Jang-Hee;Yang, Jee-Eun;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.403-407
    • /
    • 2007
  • The anodic degradation of benzoquinone(BQ), a model compound for wastewater treatment was carried out using a home-made flow-through electrochemical cell with carbon fibers. To optimize the controlled current electrolysis condition of an aqueous BQ solution, the experimental variables affecting the degradation of BQ, such as the applying current, pH, reaction time, and flow rate of the BQ solution were examined. The degradation products of the oxidation reaction were identified by High Performance Liquid Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometer. Low molecular weight aliphatic acids, and CO2 were the major products in this experiment. The removal efficiency of BQ from the solution increased with the applying current and time. 99.23% of 1.0 × 10-2 M BQ was degraded to aliphatic acids and CO2 when the applying current is 175 mA in a 12 hr electrolysis.

Development of Electrospray Micro Thruster with Super-Hydrophobic PTFE Surface Nozzle Treated by Ar and Oxygen Ion Beam

  • Lee, Y.J.;Byun, D.Y.;Si, Bui Quang Tran;Kim, S.H.;Park, B.H.;Yu, M.J.;Kim, M.Y.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.877-880
    • /
    • 2008
  • In this article, in order to fabricate polymer based electrospray device with super hydrophobic nozzle we use PTFE(polyfluorotetraethylene) plate and PMMA(polymethylmethacrylate). To obtain the super hydrophobic surface nozzle, PTFE surface is treated by argon and oxygen plasma treatment process. And evaluate the treated surface, perform measuring contact angle, SEM(Scanning Electron Microscope) and AFM(Atomic Force Microscope). We compare the performance of the super hydrophobic PTFE surface nozzle with raw PTFE and PMMA surface nozzle. For the ion beam treated PTFE nozzle, the liquid doesn't overflow and it keeps initial position and meniscus shape. From these results, we expect in cease of superhydrophobic surface nozzle jetting becomes more stable and repeatable.

  • PDF

Display Technologies for Immersive Devices and Electronic Skin (디스플레이 현황과 발전방향 -실감 및 스킨 기기로의 확대)

  • Park, Y.J.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.2
    • /
    • pp.10-18
    • /
    • 2019
  • Since the introduction of CRT(Cathode Ray Tube) in the 1950s, display technologies have been developed continuously. Flat panel displays such as PDP(Plasma Display Panel) and LCD(Liquid Crystal Display) were commercialized in the late 1990s, and OLED(Organic Light Emitting Diodes) and Micro-LED(Micro-Light Emitting Diodes) are now being developed and are becoming widespread. In the future, we expect to develop ultra-realistic, flexible, embedded sensor displays. Ultra-realistic display can be applied to AR/VR(Augmented Reality/Virtual Reality) devices and spatial light modulators for holography. The sensor-embedded display can be applied to robots; electronic skin; and security devices, including iris recognition sensors, fingerprint recognition sensors, and tactile sensors. AR/VR technology must be developed to meet technical requirements such as viewing angle, resolution, and refresh rate. Holography requires optical modulation technology that can significantly improve resolution, viewing angle, and modulation method to enable wide-view and high-quality hologram stereoscopic images. For electronic skin, stable mass production technology, large-area arrays, and system integration technologies should be developed.

ELUTION OF RESIDUAL MONOMER ACCORDING TO VARIOUS LIGHT SOURCES AND CURING TIME ON THE POLYMERIZATION OF PHOTOACTIVATED PIT AND FISSURE SEALANTS (광중합 광원의 종류와 조사시간에 따른 치면열구전색제의 미반응 모노머 용출)

  • Oh, You-Hyang;Park, Yoon-Kyung;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.421-430
    • /
    • 2004
  • The purpose of this study was to measure and compare the amount of unreacted TEGDMA from pit and fissure sealants cured with three different light sources; conventional halogen light curing unit, plasma arc light curing unit and argon laser. The specimens were eluted in distilled water for different time intervals. The time-related release of TEGDMA were analyzed by reverse-phase high performance liquid chromatography(HPLC). The result of present study can be summarized as follows: 1. The time-related release of TEGDMA decreased with increasing curing time in conventional halogen light, however, that not statistically significant difference(p>0.05). 2. The elution from the specimens cured for 6 and 9 seconds with plasma arc light was similar results corresponding with the time-related TEGBMA release, and was significantly lower than that cured for 3 seconds(p<0.05). 3. The elution of TEGDMA from the specimens cured with argon laser was significantly higher than that cured with halogen and plasma arc light(p<0.05). 4. The elution of TEGDMA from under recommended time of three different light sources were showed to be no statistically significant difference(p>0.05). 5. In time-related release of TEGDMA from recommended time of each light sources, the results correspond to 40 seconds of halogen light and 6 seconds of plasma arc light were similar(p>0.05). 6. The elution of TEGDMA, from over recommended time of three different light sources were showed to be no statistically significant difference(p>0.05). In this study, I suggest that curing time of plasma arc light is 6 and/or 9 seconds in the field of clinical pediatric dentistry claiming its effectiveness in optimal polymerization and reduced chair time.

  • PDF

The Relationship Between Hippuric Acid in Blood Plasma and Toluene Concentration in the Air of Workplace (톨루엔 폭로근로자의 혈장중 마뇨산과 공기중 톨루엔과의 상관관계)

  • Hwang, Cheon-Hyun;Lee, Won-Jin;Chang, Soung-Hoon;Kim, Hyoung-Ah
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Objectives : This study was undertaken to evaluate correlation between the levels of hippuric acid in blood plasma (HAP) and those of toluene concentration in the workplace air. Methods : Study subjects were composed of two groups; 21 workers who were occupationally exposed to toluene and 25 rural-area residents who were not exposed to any known occupational toluene source, as an exposed group and a reference group, respectively. Mean age and work duration of the exposed was 42 years and five years, respectively. Mean age of the reference was 42 years. To determine toluene concentrations in the workplace air, air sampling has been conducted for more than six hours using a personal sampler, and analyzed by a gas chromatography-flame ionization detector. Concentrations of hippuric acid in biological samples were determined by a high performance liquid chromatography-ultraviolet detector. Results : Geometric mean(geometric standard deviation) of HAP and hippuric acid in urine(HAU) for the exposed was 1.39(2.21) mg/L and 2.77(1.46) g/L, respectively, which were significantly different from those of the reference [HAP, 9.45(2.94); HAU, 0.37(0.45)]. Teluene concentration in the workplace air was 86.92(range: $45.18\sim151.23$)ppm. The level of HAP or HAU was significantly correlated (r=0.70 and r=0.63, respectively) with that of toluene in the workplace air. The estimated regression equation was logHAP(mg/L)=-3.60+1.93 log(toluene, ppm) or logHAU(g/L)=-0.85+0.67 log(toluene, ppm). The magnitude of correlation was further enhanced when analyzing relationship between toluene concentrations lower than 100 ppm and its corresponding HAP levels. Conclusion : Overall, plasma hippuric acid levels were well correlated with toluene concentrations in the workplace air, and a statistically significant correlation was observed for the samples with toluene concentration lower than 100 ppm.

  • PDF

A Novel Approach for Controlling Process Uniformity with a Large Area VHF Source for Solar Applications

  • Tanaka, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.146-147
    • /
    • 2011
  • Processing a large area substrate for liquid crystal display (LCD) or solar panel applications in a capacitively coupled plasma (CCP) reactor is becoming increasingly challenging because of the size of the substrate size is no longer negligible compared to the wavelength of the applied radio frequency (RF) power. The situation is even worse when the driving frequency is increased to the Very High Frequency (VHF) range. When the substrate size is still smaller than 1/8 of the wavelength, one can obtain reasonably uniform process results by utilizing with methods such as tailoring the precursor gas distribution by adjustingthrough shower head hole distribution or hole size modification, locally adjusting the distance between the substrate and the electrode, and shaping shower head holes to modulate the hollow cathode effect modifying theand plasma density distribution by shaping shower head holes to adjust the follow cathode effect. At higher frequencies, such as 40 MHz for Gen 8.5 (2.2 m${\times}$2.6 m substrate), these methods are not effective, because the substrate is large enough that first node of the standing wave appears within the substrate. In such a case, the plasma discharge cannot be sustained at the node and results in an extremely non-uniform process. At Applied Materials, we have studied several methods of modifying the standing wave pattern to adjusting improve process non-uniformity for a Gen 8.5 size CCP reactor operating in the VHF range. First, we used magnetic materials (ferrite) to modify wave propagation. We placed ferrite blocks along two opposing edges of the powered electrode. This changes the boundary condition for electro-magnetic waves, and as a result, the standing wave pattern is significantly stretched towards the ferrite lined edges. In conjunction with a phase modulation technique, we have seen improvement in process uniformity. Another method involves feeding 40 MHz from four feed points near the four corners of the electrode. The phase between each feed points are dynamically adjusted to modify the resulting interference pattern, which in turn modulate the plasma distribution in time and affect the process uniformity. We achieved process uniformity of <20% with this method. A third method involves using two frequencies. In this case 40 MHz is used in a supplementary manner to improve the performance of 13 MHz process. Even at 13 MHz, the RF electric field falls off around the corners and edges on a Gen 8.5 substrate. Although, the conventional methods mentioned above improve the uniformity, they have limitations, and they cannot compensate especially as the applied power is increased, which causes the wavelength becomes shorter. 40 MHz is used to overcome such limitations. 13 MHz is applied at the center, and 40 MHz at the four corners. By modulating the interference between the signals from the four feed points, we found that 40 MHz power is preferentially channeled towards the edges and corners. We will discuss an innovative method of controlling 40 MHz to achieve this effect.

  • PDF

Rapid Defect Inspection of Display Device with Optical Spatial Filtering

  • Yoon, Dong-Seon;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.56-61
    • /
    • 2000
  • We present a fast inspection method of machine vision for in-line quality assurance of liquid crystal displays(LCD) and plasma display panels(PDP). The method incorporates an optical spatial filter in the Fourier plane of the imaging optics to block the normal periodic pattern, extracting only defects real time without relying on intensive software image process. Special emphasis is on designing a collimated white light source to provide high degree of spatial coherence for effective real time Fourier transform. At the same time, a low level of temporal coherence is attained to improve defect detection capabilities by avoiding undesirable coherent noises. Experimental results show that the proposed inspection method offers a detection accuracy of 15% tolerance, which is sufficient for industrial applications.

  • PDF

Bioequivalence Study of Loxoprofen Sodium in healthy Volunteers (Loxoprofen sodium 제제(레녹스정)의 생물학적 동등성시험)

  • 최주영;유내춘;박민수;김경환
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • Loxoprofen sodium (sodium 2-[4-(2-oxocyclopentylmethyl)phenyl] propionate dehydrate) is a nonsteroidal antiinflammatory drug of $\alpha$-phenyl propionic acid derivative. To test the bioequivalence of loxoprofen, the pharmacokinetic parameters of new preparation of loxoprofen, LENOX was compared with LOXONIN as a reference drug. Fourteen healthy volunteers were entered to the stydy (Yonsei University College of Medicine, Severance Hospital IRB approval No. 9608). They were administered 60 mg of loxoprofen in 2$\times$2 cross-over design. There was one week of drug-free interval between doses. The blood sample was taken on schedule up to 8 hours, and the plasma concentration loxoprofen was measured by reverse phase high-performance liquid chromatography (HPLC) with UV-detector. There were no significant difference between two preparations when AUC, Cmax, and Tmax were compared by ANOVA. The mean differences of AUC, Cmax, and Tmax were within 20% of the reference drug: the values were 2.22,5.61, and 12.50%, respectively. The confidence limits of AUC and Cmax but not Tmax satisfied the bioequivalence criteria. These results suggest that the tested LENOX is bioequivalent to the reference drug.

  • PDF