• Title/Summary/Keyword: plasma in liquid

Search Result 614, Processing Time 0.026 seconds

A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma

  • Kim, Jae Hee;Mai, Xuan-Lan;Kim, Kyu Yeon;Sim, Min-Seok;Lee, So-Yeon;Seo, Hee-Won;Lee, Gunhee;Kim, Dae-Jung;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.56-60
    • /
    • 2019
  • Coptidis Rhizoma (CR) has been used widely in traditional medicine to treat common diseases. This study aimed to develop a high-sensitivity liquid chromatography-tandem mass (LC-MS) spectrometry method for the evaluation of the pharmacokinetics of a new natural product that contain CR extract with the main bioactive compound, berberine, at trace concentrations. Human plasma samples were pretreated with methanol by a protein precipitation method. Berberine was analyzed on a Kinetex C18 column ($2.1mm{\times}50mm$, $100{\AA}$, $1.7{\mu}m$) using a mobile phase of 10 mM ammonium formate/0.1% formic acid in water (A) and acetonitrile (B) (50:50, v/v) with a flow rate of 0.25 mL/min. The analyte was detected by using electrospray ionization in positive mode with multiple reaction monitoring (MRM). The method was sensitive, with a lower limit of quantification of 1 pg/mL, which has not been previously obtained. The method was validated (over the range of 1-50 pg/mL) and applied successfully for the pharmacokinetic study of human plasma samples.

Metabolomics Approach to Explore the Effects of Rebamipide on Inflammatory Arthritis Using Ultra Performance Liquid Chromatography/Quadrupole Time-of-Flight Mass Spectrometry

  • Moon, Su-Jin;Lee, Soo Hyun;Jung, Byung-Hwa;Min, Jun-Ki
    • Journal of Rheumatic Diseases
    • /
    • v.24 no.4
    • /
    • pp.192-202
    • /
    • 2017
  • Objective. Rebampide is a gastroprotective agent used to treat gastritis. It possesses anti-inflammatory and anti-arthritis effects, but the mechanisms of these effects are not well understood. The objective of this study was to explore mechanisms underlying the therapeutic effects of rebamipide in inflammatory arthritis. Methods. Collagen-induced arthritis (CIA) was induced in DBA/1J mice. DBA/1J mice were immunized with chicken type II collagen, then treated intraperitoneally with rebamipide (10 mg/kg or 30 mg/kg) or vehicle (10% carboxymethylcellulose solution) alone. Seven weeks later, plasma samples were collected. Plasma metabolic profiles were analyzed using ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry-based metabolomics study and metabolite biomarkers were identified through multivariate data analysis. Results. Low dose rebamipide treatment reduced the clinical arthritis score compared with vehicle treatment, whereas high dose rebamipide in CIA aggravated arthritis severity. Based on multivariate analysis, 17 metabolites were identified. The plasma levels of metabolites associated with fatty acids and phospholipid metabolism were significantly lower with rebamipide treatment than with vehicle. The levels of $15-deoxy-^{{\Delta}12,14}$ prostaglandin J2 and thromboxane B3 decreased only in high dose-treated groups. Certain peptide molecules, including enterostatin (VPDPR) enterostatin and bradykinin dramatically increased in rebamipide-treated groups at both doses. Additionally, corticosterone increased in the low dose-treated group and decreased in the high dose-treated group. Conclusion. Metabolomics analysis revealed the anti-inflammatory effects of rebamipide and suggested the potential of the drug repositioning in metabolism- and lipid-associated diseases.

Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica® Capsule (Pregabalin 150 mg)

  • Jang, Ki-Ho;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2011
  • Method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of pregabalin in plasma samples. Acquisition was performed by monitoring the transitions: m/z 160.1${\rightarrow}$142.2 for pregabalin and m/z 423.2${\rightarrow}$207.1 for losartan (as an internal standard). After cold acetonitrileinduced protein precipitation of the plasma samples, separation was performed with C18 column by isocratic mobile phase consisted of 10 mM ammonium acetate and acetonitrile (15:85, v/v). Results were linear over the concentration ranged from 0.1 to $10{\mu}g$/mL and the correlation coefficients (r) were $\geq0.99$. Intra- and inter-day precisions were $\leq6.02$ and $\leq11.04%$, respectively, and intra- and inter-day accuracies were 96.60-101.09 and 98.10-102.60%, respectively. This validated method was successfully applied to a bioequivalence study of two formulations of pregabalin, Daewoong pregabalin capsule (Daewoong Pharm. Co., Ltd.) and Lyrica$^{(R)}$ capsule (Pfizer Korea Ltd.) in twenty eight healthy Korean volunteers. The subjects received a single oral dose of each formulation (150 mg as pregabalin) in a randomized $2{\times}2$ crossover study and plasma samples were obtained from each subject at predetermined time intervals. Then, the pharmacokinetic parameters ($AUC_{0-t}$, $C_{max}$ and $T_{max}$) were calculated and statistically analyzed to assess the differences between two formulations. The 90% confidence intervals for the log-transformed data were acceptable range of log 0.8-log 1.25 (e.g., log 1.0048-log 1.0692 for AUC0-t, log 0.9142-log 1.0421 for $C_{max}$). Thus, $AUC_{0-t}$ and $C_{max}$ met the criteria of the Korea Food and Drug Administration (KFDA) for bioequivalence test indicating that Daewoong pregabalin capsule was bioequivalent to Lyrica$^{(R)}$ capsule.

A New Xenon Plasma Flat Fluorescent Lamp Enhanced with MgO Nano-Crystals for Liquid Crystal Display Applications

  • Lee, Yang-Kyu;Heo, Seung-Taek;Lee, You-Kook;Lee, Dong-Gu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.186-189
    • /
    • 2010
  • Nano-sized MgO single crystal powders have recently been reported to emit ultraviolet by stimulation of electrons in a vacuum. In this study, nanocrystalline MgO powders were applied to a xenon plasma flat fluorescent lamp (FFL) for a liquid crystal display backlight to improve its emission efficiency through the extra ultraviolet from the nano-MgO crystals. For comparison, a MgO nano-thin film was applied directly on the phosphors inside a lamp panel through e-beam evaporation. Adding MgO nano-crystal powders to the phosphors improved the luminance and efficiency of FFLs by around 20% and MgO nano-crystal coverage of 40% of the phosphor provided the best FFL emission characteristics; however, application of MgO thin film to the phosphors degraded the emission characteristics, even compared to FFLs without MgO. This was due to insufficient ultraviolet stimulation of the phosphors and the crystallinity and low secondary electron coefficient of the MgO.

The separation of arsenic metabolites in urine by high performance liquid chromatography-inductively coupled plasma-mass spectrometry

  • Chung, Jin-Yong;Lim, Hyoun-Ju;Kim, Young-Jin;Song, Ki-Hoon;Kim, Byoung-Gwon;Hong, Young-Seoub
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.18.1-18.9
    • /
    • 2014
  • Objectives The purpose of this study was to determine a separation method for each arsenic metabolite in urine by using a high performance liquid chromatography (HPLC)-inductively coupled plasma-mass spectrometer (ICP-MS). Methods Separation of the arsenic metabolites was conducted in urine by using a polymeric anion-exchange (Hamilton PRP X-100, $4.6mm{\times}150mm$, $5{\mu}m$) column on Agilent Technologies 1260 Infinity LC system coupled to Agilent Technologies 7700 series ICP/MS equipment using argon as the plasma gas. Results All five important arsenic metabolites in urine were separated within 16 minutes in the order of arsenobetaine, arsenite, dimethylarsinate, monomethylarsonate and arsenate with detection limits ranging from 0.15 to $0.27{\mu}g/L$ ($40{\mu}L$ injection). We used G-EQUAS No. 52, the German external quality assessment scheme and standard reference material 2669, National Institute of Standard and Technology, to validate our analyses. Conclusions The method for separation of arsenic metabolites in urine was established by using HPLC-ICP-MS. This method contributes to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies for arsenic exposure in South Korea.

Disinfection Properties and Variation in the Ozone Concentration in Seawater Generated Using a Low-Temperature Dielectric Barrier Discharge Plasma Reactor (저온 유전체장벽 플라즈마로 생성된 해수중의 오존농도 변동과 살균 특성)

  • Lee, Young Sik;Kim, Yoonbin;Kim, Kwang Seog;Han, Hyung-Gyun
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1181-1186
    • /
    • 2012
  • We studied the ozone concentrations generated by low-temperature dielectric barrier discharge plasma reactor after adding air and phytoplankton to control the ozone concentrations in seawater. We also examined the numbers of bacteria and Vibrio spp. after treatment using the plasma reactor. As the airflow rate was increased, more ozone was removed. Although marked variation in the ozone decrease was observed with and without airflow, the rate of ozone removal did not increase proportionately with the airflow rates. The ozone concentration decreased with increasing organic matter and time. The amount of organic matter seems to be an important factor decreasing the dissolved ozone concentration in liquid. The ozone concentration was 0.07, 0.32, 1.28, and 2.3 mg/L when operating the plasma reactor for 30, 60, 180, and 300 s, respectively; i.e., the ozone concentration increased with the reactor operating time. The initial numbers of bacteria and Vibrio spp. were 800 and 480 CFU/mL, respectively. After operating the plasma reactor at a flow rate of 6 L/min for 30 s, no bacteria or Vibrio spp. were detected. The disinfection effect of this plasma reactor seems to be superior to that of a conventional ozone generator.

Determination of new anti-HIV agents, the KR-V series, in rat plasma using microbore high-performance liquid chromatography (HPLC를 이용한 랫드혈장내 새로운 항HIV제 KR-V series의 분석법)

  • Lee, Young-mi;Park, Myung-jin;Kim, Jin-suk;Shin, Ho-chul
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.741-746
    • /
    • 2000
  • We have developed a rapid, simple and precise high-performance liquid chromatographic (HPLC) method using an UV detection system for the determination of new anti-HIV candidates, nineteen KR-V compounds, in rat plasma. We used a analytical columnn of $C_{18}$ ($5{\mu}m$, $250{\times}2.0mm$ I.D.) and a mobile phase of water and ACN mixture (40/60, v/v). Under these conditions, all the KR-V compounds were readily separated from plasma with retention times of 4-12 min. The limits of quantitation for the 19 KR-V compounds were 15-30 ng/ml. The recoveries from the plasma were higher than 85% (C.V.<10%) with exception of KR-V 2, 7 and 15. The compounds KR-V 2, 7 and 15, containing ester moieties, were found to be unstable in plasma. This result suggests that esters, like KR -V 2, 7 and 15, should be excluded from future structure design studies of anti-HIV KR-V agents. In conclusion, the current HPLC method is a valuable analytical tool for investigating the pharmacokinetics of the KR-V series in rats.

  • PDF

Quantitation of Mevinolinic Acid in Human Plasma by HPLC (고속액체크로마토그래피를 이용한 사람 혈장중 메비놀린 산의 정량)

  • Oh, Han-Suk;Park, Dong-Young;Seo, Sung-Hoon;Kim, Young-Gwan;Hong, Seon-Pyo;Choi, Young-Wook;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.279-282
    • /
    • 2000
  • Simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a HMG-CoA reductase inhibitor, $lovastatin^{TM}$ and its active metabolite (mevinolinic acid) in human plasma. The method involved solid phase extraction of mevinolinic acid and internal standard using Sep-Pak Cartridge. Samples were analyzed by reversed-phase HPLC using $Capcell-Pak\;C_{18}$ column with ultraviolet detection at 238 nm. The quantitation limit of mevinolinic acid was 2 ng/ml and the calibration curve was linear over the range of 2-50 ng/ml $(r^2>0.999)$ with human plasma. The analyses of quality control samples indicated that the normal values could be predicted with an accuracy >97%. The intra- and inter-day coefficients of variation for the analyses were <10%. The average recoveries were similar (79%) for mevinolinic acid and methylmevinolinic acid. The method described has been successfully applied to the quantification of mevinolinic acid in about 1,000 human plasma samples over six-month period.

  • PDF

Effect of Processing Parameters and Powder Size on Microstructures and Mechanical Properties of Y2O3 Coatings Fabricated by Suspension Plasma Spray

  • Kim, Sun-Joo;Lee, Jung-Ki;Oh, Yoon-Suk;Kim, Seongwon;Lee, Sung-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.395-402
    • /
    • 2015
  • The suspension plasma spray (SPS) technique has been used to obtain dense $Y_2O_3$ coatings and to overcome the drawbacks of the conventional air plasma spray (APS). SPS uses suspensions containing micrometer or sub-micrometer sized powders dispersed in liquid media. In this study, microstructure developments and mechanical properties have been investigated as functions of particle size of source material and plasma processing parameters such as plasma power and stand-off distance. The microstructure of the coating was found to be highly related to the particle size and the plasma processing parameters, and it was directly reflected in the hardness and the adhesion strength. When fine powder (BET $16.4m^2/g$) was used as a raw material in the suspension, there was, with increasing stand-off distance, a change from a dense structure with a slightly bumpy surface to a porous structure with a cauliflower-like surface. On the other hand, when a coarse powder (BET $2.8m^2/g$) was used, the coating density was lower, with microscopic splats on the surface. Using fine $Y_2O_3$ powders, the coating layer with an optimum short stand-off distance showed a high hardness of approximately 90% of that of sintered $Y_2O_3$ and an adhesion strength several times higher than that of the coating by conventional APS.

Physical properties and determination of eupatilin, a new antigastritic agent, by high performance liquid chromatography

  • Jang, Ji-Myun;Shim, Hyun-Joo;Ahn, Byung-Ok;Kim, Soon-Hoe;Kim, Won-Bae
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.215.3-216
    • /
    • 2003
  • Eupatilin is a major active component of Stillen\ulcorner(Artemisia Herba Extract) having a potent antigastritic effect. We investigated the physical properties of eupatilin using high performance liquid chromatography. Solubility, stability & partition coefficient of eupatilin were investigated. pH-stability of eupatilin was examined over the broad range through pH1-9 at 37$^{\circ}C$ & it has good stability above the broad range pH. The solubility of eupatilin was extremely low but the value of logP was more than 2. Also, a high performance liquid chromatographic method was developed for the determination of eupatilin in rat plasma. (omitted)

  • PDF