• Title/Summary/Keyword: plant parameters

Search Result 1,814, Processing Time 0.038 seconds

Nematicidal Activity of Some Fluorescent Pseudomonads on Cyst Forming Nematode, Heterodera cajani and Growth of Sesamum indicum var. RT1

  • Kumar, Tarun;Kang, Sun-Chul;Maheshwari, Dinesh Kumar
    • Journal of Applied Biological Chemistry
    • /
    • v.48 no.4
    • /
    • pp.161-166
    • /
    • 2005
  • Among 24 isolates of fluorescent Pseudomonads, 5 isolates named as LPT1, LPT2, LPT3, LPT4 and LPT5 were screened in vitro for their nematicidal activity against cyst forming nematode, Heterodera cajani causing patchiness, poor and stunting growth besides discoloration in Sesamum indicum. Second stage juveniles of H. cajani hatched from egg masses were collected from roots of host plant and subjected to fresh and heat-treated culture filtrate of isolates for 24 h. Mortality of H. cajani was recorded on the basis of parameters used for test organism bioassay. Among these isolates, Pseudomonas aeruginosa LPT5 caused maximum mortality towards second stage juvenile of H. cajani in vitro. Five isolates were used as seed coating for the management of cyst forming nematode H. cajani on sesame in green house condition. The strains LPT5 was better than the other strains in reducing the population of H. cajani both in vitro and in vivo. The reduction in cyst and juveniles population was found to be 49 and 60%, respectively when seeds were coated with strain LPT5. Among other strains, LPT4 was also found to inhibit the cyst and juveniles population 12 and 36% respectively. Increases in early vegetative plant growth parameters recorded in both in vitro and in vivo further revealed the significance of indigenous bacteria in comparison to introduced strain.

Removal Characteristics of Sr Ion by Na-A Zeolite Synthesized using Coal Fly Ash Generated from a Thermal Power Plant (화력발전소에서 발생하는 석탄비산재로부터 합성한 Na-A 제올라이트의 Sr 이온 제거 특성)

  • Lee, Chang-Han;Kam, Sang-Kyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.363-371
    • /
    • 2017
  • This study evaluates the adsorption properties of Sr ions in an aqueous solution of the synthetic zeolite (Z-Y1) prepared using coal fly ash generated from a thermal power plant. In order to investigate the adsorption characteristics, the effects of various parameters such as the initial concentrations of Sr ion, contact time, and solution pH were investigated in a batch mode. The Langmuir and Redlich-Peterson model fitted the adsorption isotherm data better than the Freundlich model. The maximum adsorption capacity of Sr ions, as determined the Langmuir model, was 181.68 mg/g. It was found that by varying the Sr ion concentration, pH, and temperature, the pseudo-second-order kinetic model describes the adsorption kinetics of the Sr ion better than the pseudo-first-order kinetic model. The calculated thermodynamic parameters of ${\Delta}H^0$ and ${\Delta}G^0$ showed that the adsorption of Sr ions on Z-Y1 was occurred through a spontaneous and an endothermic reaction. We found that the adsorption of Sr ions by Z-Y1 was more affected by pH than by temperature and Sr ion concentration.

Effect of raw water quality decrease on water treatment costs (상수원수 수질저하가 정수처리 비용에 미치는 영향)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.239-250
    • /
    • 2020
  • In this study, effects of five raw water quality parameters (turbidity, odor compounds caused by algae, filter clogging caused by algae, pH increase caused by algae, and organic matter) on improvements and operations costs of typical water treatment plant (WTP) were estimated. The raw water quality parameters were assumed the worst possible conditions based on the past data and costs were subsequently estimated. Results showed that new water treatment facilities were needed, such as a selective intake system, an advanced water treatment processes, a dual media filter, a carbonation facility, and a re-chlorination facility depending on water quality. Furthermore, changes needed to be made in WTP operations, such as adding powered activated carbon, increasing the injection of chlorine, adding coagulation aid, increasing the discharge of backwashed water, and increasing the operation time of dewatering facilities. Such findings showed that to reliably produce high-quality tap water and reduce water treatment costs, continuous improvements to the quality of water sources are needed.

Optimal Design for Rule-Based Fuzzy Logic Controller Using GA (유전알고리즘을 이용한 규칙 기반)

  • No, Gi-Gap;Ju, Yeong-Hun;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.145-152
    • /
    • 1999
  • This paper presents an optimal design method for fuzzy logic controllers using genetic algorithms. In general, the design of fuzzy logic controllers has difficulties in the acquisition of exper's knowledge and relies to a great extent on empirical and heuristic knowledge which, in many cases, cannot be objectively justified. So, the performance of the controller can be degraded in the case of plant parameter variations or unpredictable incident which the designer may have ignored, and parameters of the fuzzy logic controller obtained by expert's control action may not be global. To solve these problems, the proposed method using genetic algorithms in this paper, can tune the parameters of fuzzy logic controller including scaling factors and determine the appropriate number of fuzzy reles systematically and automatically. We provide the second drder dead time plant and inverted pendulum system to evaluate the feasibility and generality of our proposed method. Comparison shows that the proposed controller can producd higher accuracy and a smaller number of fuzzy rules than manually tuned fuzzy logic controller.

  • PDF

Optimization of Algerian Thymus fontanesii Boiss. & Reut Essential Oil Extraction by Electromagnetic Induction Heating

  • Ali, Lamia Sid;Brada, Moussa;Fauconnier, Marie-Laure;Kenne, Tierry
    • Natural Product Sciences
    • /
    • v.24 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • The present study deals with the determination of optimal values of operating parameters such as the temperature of heating, the mass of the plant material and the volume of water leading to the best yield of electromagnetic induction (EMI) heating extraction of Algerian Thymus fontanesii essential oil. After an appropriate choice of the three critical variables, eight experiments leaded to a mathematical model as a first-degree polynomial presenting the response function (yield) in the relation to the operating parameters. From the retained model, we were able to calculate the average response, the different effects and their interactions. The maximum of essential oil recovery percentage relative to the initial mass of plant material was 1.69%, and was obtained at ($140^{\circ}C$, 250 g and 4.5 L). The chemical composition of the Algerian T. fontanesii essential oil under the obtained optimal conditions ($140^{\circ}C$, 250 g and 4.5 L), determined by GC/MS and GC/FID, reveled of the presence of major components such as: carvacrol ($70.6{\pm}0.1%$), followed by p-cymene ($8.2{\pm}0.2%$).

Development of Green's Functions for Fatigue Damage Evaluation of CANDU Reactor Coolant System Components (CANDU형 원전 주요기기의 피로손상 평가를 위한 그린함수 개발)

  • Kim, Se Chang;Sung, Hee Dong;Choi, Jae Boong;Kim, Hong Key;Song, Myung Ho;Nho, Seung Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.38-43
    • /
    • 2011
  • For the efficient and safe operation of nuclear power plant, evaluating quantitatively aging phenomenon of major components is necessary. Especially, typical aging parameters such as stresses and cumulative usage factors should be determined accurately to manage the lifetime of the plant facility. The 3-D finite element(FE) model is generated to calculate the aging parameters. Mechanical and thermal transfer functions called Green's functions are developed for the FE model with standard step input. The stress results estimated from transfer functions are verified by comparing with 3-D FE analyses results. Lastly, we suggest an effective fatigue evaluation methodology by using the transfer functions. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system.

Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation) (DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구)

  • Lee., Byoung-Ho;Kim, Sung-Hyuk;Lee, Sang-Bae;Kim, Mi-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.

A Study on the Power Station Application and Performance Evaluation of 10㎿ grade Intelligent Digital Governor (10㎿급 인텔리전트 디지털 가버너의 현장적용 및 성능평가에 관한 연구)

  • 조성훈;장민규;전일영;이성근;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.314-317
    • /
    • 2002
  • This paper present a methods for performance evaluation of digital governor and we treat the way to reduce the trial and error when the developed digital governing system is applied to station. The parameters of the model are estimated using input-output data, the model adjustment technique and a genetic algorithm(GA). To verify validity of the completed model, the comparision model and real output signals have been carried out. The developed digital governing system is applied to Sumjingang hydro-power plant, Korea Hydro Nuclear Power Corporation, it has replaced mechanical governing system. Test was performed in order to demonstrate the performance evaluation of the digital governor parameters.

  • PDF

The level control of steam generator in nuclear power plant by neural network 2-DOF PID controller (신경망 2-자유도 PID제어기를 이용한 원자력 발전소용 증기 발생기 수위제어)

  • Kim, Dong-Hwa;Lee, Won-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.3
    • /
    • pp.321-328
    • /
    • 1998
  • When we control the level of the steam generator in the nuclear power plants, a swell and shrink arises from many disturbances such as feed water rate, feed water temperature, main steam flow rate, and coolant temperature. If we use the conventional type of PI controller in this system, we will not have stability during controlling at lower power, the removal function of disturbances, and a load follow-up control effectively. In this paper, we study the application of a 2-Degree of Freedom(2-DOF) PID controller to the level control of the steam. generator of nuclear power plants through the simulation and the experimental steam generator. We use the parameters $\alpha$, $\beta$, $\gamma$ of the 2-DOF PID controller for the removal of disturbances and the parameters Kp,Ti,Td of the conventional type of PID controller for controlling setpoint. The back-propagation learning algorithm of neural network is used for tuning the 2-DOF PID controller. We can find satisfactory results of the removal of the disturbances and the tracking function in the change of setpoint through the simulation and experimental steam generator.

  • PDF

Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer (순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석)

  • Lee, Kong-Hoon;Kim, Oak-Joong;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.