• Title/Summary/Keyword: pixel matrix

Search Result 194, Processing Time 0.038 seconds

통계적 방법을 이용한 니켈도금 표면거칠기의 텍스처 해석 (Texture Analysis of Nickel Plating Surface Roughness Using Statistical Method)

  • 공재항;사승윤;유봉환
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1254-1260
    • /
    • 2000
  • There have been many developments in super precision working technique and working method up to, now. But, it is very difficult to evaluate working surface accurately without the technicians experience and judgment. Surface roughness tester using stylus was used to measure surface condition generally But this method is not so desirable because of damage on test piece caused by contact between the workpiece and the stylus sensor. As a result, non-contact method was known as a good way to carry, out this process without damage. However, this is a difficult one among the various measuring methods. So we are tying to suggest a new method using texture analysis through image processing to get a surface information in worked test piece. Co-occurrence matrix using difference of gray levels between a pixel and its neighboring one was used to study behavior of surface roughness and to J acquire data for analysis. Standard specimen was adapted to verify this research. We suggest texture information method in order to evaluate surface state for the best measurement system.

신경망을 이용한 인쇄체 한자의 인식 (An recognition of printed chinese character using neural network)

  • 이성범;오종욱;남궁재찬
    • 한국통신학회논문지
    • /
    • 제18권9호
    • /
    • pp.1269-1282
    • /
    • 1993
  • 본 논문에서는 종래의 결정론적 방법과 신경망을 이용하여, 인쇄체 한자를 인식하는 방법을 제안하였다. 먼저 한자를 구성하는 획성분의 4방항백터를 추출하였다. 다음에 구해진 방향벡터에 무게중심의 메쉬를 만든 다음, 각 메쉬내의 흑화소 길이로 8$\times$8의 특징 매트릭스를 구성하였다. 정규화한 특징 매트릭스 값은 14의 문자형식으로 1차 분류하기위해 신경망에 입력으로 하였고, 이 분류된 문자는 부수를 인식하는 부수인식 신경망에서 다시 2차분류하였다. 마지막으로 2차분류된 문자는 입력한사와 표준한자와의 유사도를 적용하여 최종인식을 행하였다. 본 알고리즘이 한자의 인치에 유효함을 보였다.

  • PDF

Water body extraction in SAR image using water body texture index

  • Ye, Chul-Soo
    • 대한원격탐사학회지
    • /
    • 제31권4호
    • /
    • pp.337-346
    • /
    • 2015
  • Water body extraction based on backscatter information is an essential process to analyze floodaffected areas from Synthetic Aperture Radar (SAR) image. Water body in SAR image tends to have low backscatter values due to homogeneous surface of water, while non-water body has higher backscatter values than water body. Non-water body, however, may also have low backscatter values in high resolution SAR image such as Kompsat-5 image, depending on surface characteristic of the ground. The objective of this paper is to present a method to increase backscatter contrast between water body and non-water body and also to remove efficiently misclassified pixels beyond true water body area. We create an entropy image using a Gray Level Co-occurrence Matrix (GLCM) and classify the entropy image into water body and non-water body pixels by thresholding of the entropy image. In order to reduce the effect of threshold value, we also propose Water Body Texture Index (WBTI), which measures simultaneously the occurrence of repeated water body pixel pair and the uniformity of water body in the binary entropy image. The proposed method produced high overall accuracy of 99.00% and Kappa coefficient of 90.38% in water body extraction using Kompsat-5 image. The accuracy analysis indicates that the proposed WBTI method is less affected by the choice of threshold value and successfully maintains high overall accuracy and Kappa coefficient in wide threshold range.

Flexible Microelectronics; High-Resolution Active-Matrix Electrophoretic Displays

  • Miyazaki, Atsushi;Kawai, Hideyuki;Miyasaka, Mitsutoshi;Nebashi, Satoshi;Shimoda, Tatsuya;McCreary, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.575-579
    • /
    • 2005
  • A beautiful, flexible active-matrix electrophoretic display (AM-EPD) device is reported. The flexible AM-EPD device has a $40.0{\times}30.0\;mm^2$ display area, measures about 0.27 mm in thickness, weighs about 0.45 g and possesses only 20 external connections. The flexible AM-EPD device displays clear black-and-white images with 5 gray-scales on $160{\times}120$ pixels. The display is free from residual image problems, because we use an area-gray-scale method on $320{\times}240$ EPD elements, each of which is driven with binary signals. Each pixel consists of 4 EPD elements. In addition, since the response time of the electrophoretic material is as long as approximately 400 ms and since the display possesses a large number of EPD elements, we have developed a special driving method suitable for changing EPD images comfortably. A complete image is formed on the AM-EPD device, consisting of a reset frame and several, typically 6, image frames.

  • PDF

Development of 40 inch Full Color AMOLED Display

  • Chung, K.;Huh, J.M.;Sung, U.C.;Chai, C.C.;Lee, J.H.;Kim, H.;Lee, S.P.;Goh, J.C.;Park, S.K.;Ko, C.S.;Koh, B.S.;Shin, K.J.;Choi, J.H.;Jung, J.H.;Kim, N.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.781-784
    • /
    • 2005
  • We have developed technology to fabricate large-size active matrix organic light-emitting diode (AMOLED) displays with good color purity. Using these innovations, we have developed a 40inch diagonal WXGA AMOLED full color display. Because the TFT circuitry occupies a large portion of the pixel structure, an efficient white emission OLED is essential to integrate the device onto the active matrix backplane. The development of these technologies enables OLED displays to fulfill the requirements for larger size applications such as HDTVs

  • PDF

Methodology for numerical evaluation of fracture resistance under pinch loading of spent nuclear fuel cladding containing reoriented hydrides

  • Seyeon Kim;Sanghoon Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.1975-1988
    • /
    • 2024
  • It is important to maintain cladding integrity in spent nuclear fuel management. This study proposes a numerical analysis method to evaluate the fracture resistance of irradiated zirconium alloy cladding under pinch load known to cause Mode-III failure. The mechanical behavior and fracture of the cladding under pinch loading can be evaluated by a Ring Compression Test (RCT). To simulate the fracture of hydride precipitates, zirconium matrix, and Zr/hydride interfaces under the stress field generated by RCT, a micro-structure crack propagation simulation method based on Continuum Damage Mechanics (CDM) has been proposed. Our RCT simulation model was constructed from microscopic images of irradiated cladding. In this study, we developed an automated process to generate a pixel-based finite element model by separating the hydride precipitates, zirconium matrix, and interfaces using an image segmentation method. The appropriate element size was selected to ensure the efficiency and accuracy of a crack propagation simulation. The load-displacement curves and strain energies from RCT were compared and analyzed with the simulation results of different element sizes. The finalized RCT simulation model can be used to establish the failure criterion of fuel rods under pinch loading. The advantages and limitations of the proposed method are fully discussed here.

PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성 (Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction)

  • 최성욱;최춘기;이규복;석재동
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.171-175
    • /
    • 2008
  • 목적 : 소아환자는 성인과는 다르게 작은 체구로 인하여 병소의 위치확인과 정량평가하기에 다소 어려움이 있다. 저자들은 phantom 실험과 소아환자를 대상으로 PET/CT에서의 영상재구성 시 DFOV 변화에 따른 SUV값의 유용성을 평가하였다. 실험재료 및 방법 : Uniform NU2-94 Phantom에 0.023 MBq/cc의 $^{18}F$-FDG를 채운 후 10 min 동안 얻었으며, 재구성시 DFOV는 50, 45, 40, 35, 30, 25 cm로 변화를 주었다. 환자 영상은 2007년 10월부터 2008년 1월까지 소아 암 진단을 받았거나 의심되는 20명, 영상재구성 시 DFOV는 50~25 cm 까지 각 5 cm 변화를 주었다. phantom과 소아 환자의 재구성 된 영상에서 DFOV 변화에 따라 각각의 pixelsize와 $SUV_{max}$ 값 변화를 비교 분석하였다. 결과 : phantom실험에서 DFOV가 50, 45, 40, 35, 30, 25 cm로 감소함에 따라 pixel size는 각각 3.906, 3.515, 3.125, 2.734, 2.343, 1.953 mm로 감소하였고, $SUV_{max}$는 각각 1.275, 1.323, 1.359, 1.418, 1.524, 1.685로 증가를 보였다. 환자 영상에서는 DFOV 50 cm를 기준으로, $SUV_{max}$는 4.629, 4.786, 4.995, 5.231, 5.373, 5.659의 증가 변화와. 11.9, 12.22, 12.43, 12.52, 12.80, 13.23으로 증가를 나타냈다. 또한 DFOV 5 cm가 감소하면서 40 cm 까지는 좋은 영상을 얻을 수 있었지만, DFOV 35 cm 부터는 truncated artifact가 나타나는 것을 알수 있었다. 결론 : phantom을 이용한 $SUV_{max}$ 값은 DFOV가 5 cm씩 감소함에 따라 평균 수치가 증가하였으며, DFOV 50 cm를 기준으로 각각 3.7, 6.5, 11.2, 19.5, 32.1%로 증가함을 알았다. 소아환자 영상에서도 DFOV가 감소함에 따라 phantom 실험에서와 같이 증가하는 양상을 보였다. 영상 재구성 시 matrix size의 변화 없이 DFOV를 감소시키는 것만으로도 pixel size가 줄어들기 때문에 영상의 질을 향상시킬 수 있으며, 이는 소아 환자의 영상을 성인에서와 같은 방법으로 재구성한 후 확대하여 보는 것 보다 효과적이라 할 수 있다. 그러나 DFOV를 35 cm 이하로 적용할 경우 truncated artifact가 발생할 수 있으므로 제한적으로 적용해야 할 것이라 생각된다. 그러므로 DFOV의 변화는 소아 환자에 보다 좋은 영상을 얻을 수 있지만, 영상 판독은 DFOV의 변화에 따른 SUV값의 변화를 고려해야 할 것으로 사료된다.

  • PDF

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF

효율적인 학습규칙의 신경망 기반 독립성분분석을 이용한 영상신호의 분리 및 특징추출 (Separations and Feature Extractions for Image Signals Using Independent Component Analysis Based on Neural Networks of Efficient Learning Rule)

  • 조용현
    • 한국지능시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.200-208
    • /
    • 2003
  • 본 연구에서는 효율적인 학습규칙의 신경망 기반 독립성분분석기법을 이용한 영상신호의 분리와 특징추출을 제안하였다. 제안된 학습규칙은 할선법과 모멘트를 이용한 조합형 고정점 학습알고리즘이다. 여기서 할선법은 독립성분 상호간의 정보를 최소화하기 위한 목적함수의 최적화 과정에서 요구되는 1차 미분에 따른 계산을 간략화하기 위함이고, 모멘트는 최적화 과정에서 발생하는 발진을 억제하여 보다 빠른 학습을 위함이다. 제안된 기법을 $512\times512$의 픽셀을 가지는 10개의 영상을 대상으로 임의의 혼합행렬에 따라 발생되는 혼합영상의 분리에 적용한 결과, 뉴우턴법에 기초한 기존의 알고리즘과 할선법만에 기초한 알고리즘보다 각각 우수한 분리률과 빠른 분리속도가 있음을 확인하였다. 또한 $256\times256$ 픽셀의 10개 지문상과 $480\times225$ 픽셀의 지폐영상에서 선택된 각각 10,000개의 3가지 영상패치들을 대상으로 적용한 결과, 제안된 기법은 뉴우턴법이나 할선법의 알고리즘보다도 빠른 특징추출 속도가 있음을 확인하였다. 한편 추출된 $16\times16$ 펙셀의 160개 독립성분 기저벡터 각각은 영상 각각에 포함된 공간적인 주파수 특성과 방향성을 가지는 경계 특성이 잘 드러나는 국부적인 특징들임을 확인하였다.

형광체 결합형 X선 영상검출기의 공간 해상력 몬테카를로 시뮬레이션 (Optical Monte Carlo Simulation on Spatial Resolution of Phosphor Coupled X-ray Imaging Detector)

  • 강상식;김소영;신정욱;허승욱;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.328-328
    • /
    • 2007
  • Large area matrix-addressed image detectors are a recent technology for x-ray imaging with medical diagnostic and other applications. The imaging properties of x-ray pixel detectors depend on the quantum efficiency of x-rays, the generated signal of each x-ray photon and the distribution of the generated signal between pixels. In a phosphor coated detector the light signal is generated by electrons captured in the phosphor screen. In our study we simulated the lateral spread distributions for phosphor coupled detector by Monte Carlo simulations. Most simulations of such detectors simplify the setup by only taking the conversion layer into account neglecting behind. The Monte Carlo code MCNPX has been used to simulate the complete interaction and subsequent charge transport of x-ray radiation. This has allowed the analysis of charge sharing between pixel elements as an important limited factor of digital x-ray imaging system. The parameters are determined by lateral distribution of x-ray photons and x-ray induced electrons. The primary purpose of this study was to develop a design tool for the evaluation of geometry factor in the phosphor coupled optical imaging detector. In order to evaluate the spatial resolution for different phosphor material, phosphor geometry we have developed a simulation code. The developed code calculates the energy absorption and spatial distribution based on both the signal from the scintillating layer and the signal from direct detection of x-ray in the detector. We show that internal scattering contributes to the so-called spatial resolution drop of the image detector. Results from the simulation of spatial distribution in a phosphor pixel detector are presented. The spatial resolution can be increased by optimizing pixel size and phosphor thickness.

  • PDF