Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF

$GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발 (Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry)

  • 박지연;이정우;최경식;홍세미;박병문;배용기;정원균;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.113-119
    • /
    • 2010
  • GafChromic EBT2 필름 dosimetry에 필요한 품질 관리용 소프트웨어를 개발하였다. 개발한 프로그램에서는 EBT2 필름특성에 맞게 붉은색, 초록색, 파란색 및 회색 채널에 따른 필름 교정이 가능하도록 하였다. 또한 평판형 스캐너의 빛의 산란 효과나 필름 내 방사선에 반응하는 물질(active layer)의 두께 차이가 선량 검증에 미치는 영향을 평가할 수 있도록 하였다. EBT2 필름을 이용한 측정 결과는 방사선 치료계획 시스템, ECLIPSE 또는 2차원 이온 전리함 배열의 선량 값과 비교할 수 있다. 개발한 소프트웨어를 이용한 GafChromic EBT2 필름의 선량 검증은 파일 입력, 잡음 제거, 배경 보정(background) 및 반응 물질 보정(active layer correction), 선량 계산 및 평가 단계를 통해서 이루어진다. 절대적 또는 상대적 배경 보정 방법을 선택적으로 적용할 수 있으며 필름 교정 결과 및 교정 곡선에 대한 적합식(fitting equation)은 결과 파일로 출력할 수 있다. 선량 행렬의 화소 크기 조정을 위한 보간법, 대화식 영상 이동 및 회전 기능을 이용하여 선량 행렬 간 구조적 위치를 일치시킨 후, 빔 측면도(beam profile) 및 등선량곡선(isodose curve)을 비교할 수 있다. 또한 거리 및 선량 차이에 대한 허용값을 적용하여 gamma index 및 gamma histogram을 이용한 선량 분석이 가능하다. 60도 동적 쐐기 조사면과 전립선 세기조절방사선치료의 조사면을 이용하여 개발한 소프트웨어의 기초 성능 평가를 수행하였을 때, 동적 쐐기 조사면에서 ECLIPSE와 EBT2 필름 간 절대적 빔 측면도는 3% 오차 범위 내에서 일치하였다. EBT2 필름을 이용한 두 종류의 선량 검증 모두, 99% 이상의 영역이 3 mm, 3%의 gamma index의 평가 기준을 만족하였다. 개발한 선량 검증용 소프트웨어를 이용하여 주기적으로 수행되는 일반적인 품질관리뿐만 아니라 빔의 세기가 조절된 복잡한 조사면의 품질관리에도 활용할 수 있으며, Radiochromic 필름을 이용한 선량 평가에 필요한 유용한 분석 툴을 제공할 수 있다.