• Title/Summary/Keyword: pitch difference

Search Result 332, Processing Time 0.023 seconds

Performance Analysis of an Indoor Heat Exchanger with R-410A for GHP Application

  • Lee, Jong-Ho;Kim, Sung-Soo;Cha, Woo-Ho;Kang, Yong-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.4
    • /
    • pp.129-134
    • /
    • 2009
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchangers with R-410A for Gas Engine Driven Heat Pump (GHP) application and to find the optimum design conditions of indoor heat exchangers by parametric analysis for the key parameters. The key parameters are number of tube row, number of tube pipe, fin pitch and transverse tube pitch. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R-410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant. This study determines the heat exchanger size, air side/refrigerant side pressure drop and overall heat transfer coefficient. Optimum design conditions for the key parameters are also determined by the parametric analysis. The results show that number of rows and pipes, fin pitch have significant effect on the heat exchanger size. It is also found that the tube length of the louver fin is $17{\sim}30%$ shorter than that of the plate fin.

The Change of the Voice Parameters in Long-term Sensorineural Hearing Loss Patients (장기간의 양측 감각신경성 난청환자에서 음성지표의 변화)

  • 윤자복;조경래;정상원;최정환;유영삼;우훈영;이강수
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.2
    • /
    • pp.140-144
    • /
    • 2001
  • Backgrounds & Objectives : Prolonged hearing loss was considered as one of the factors which have the potential to cause vocal changes. However, the analysis of quality of phonation in hearing loss patients has not been achieved enough. The purpose of the study was to evaluate the difference in objective acoustic parameters between long-term hearing impaired patients and normal control group. Material & Methods : The material of this investigation comprised a group of 20 patients (M : F=10 : 10) with moderate or profound hearing loss(over 50dB). The duration of all hearing loss was over 1 year. All of them underwent the acoustic examinations comprising electroglottography, multidimensional voice program and formant analysis during phonation of the bowels /a/ with free confortable tone and /i/ with voluntary high tone. The results of the acoustic examinations were compared with those of a control group, composed of 20 sex- and age-matched normal hearing subjects. Results : In the male hearing loss subjects, the significant increase was detected in pitch and shimmer during phonation of /a/ and in pitch during phonation of /i/. In addition, this group was characterized by decreased fundamental frequency during phonation of /i/. In female, there was no difference between hearing loss group and normal control group except a decreased formant 1 frequency. Conclusion : Long-term moderate and profound sensorineural hearing loss could affect the objective voice parameters.

  • PDF

A Study on the Improvement of the Control Circuit Design of Controllable Pitch Propeller (가변피치프로펠러의 제어회로 설계 개선에 관한 연구)

  • Kim, Dong-Young;Kang, Gu-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.52-60
    • /
    • 2019
  • The control circuit of the CPP applied to FFX Batch-I and LST-II may be capable of generating a backward pitch even when the grounding phenomenon occurs in the other system. The purpose of this study was to improve the CPP control circuit to maintain the pitch even in the event of grounding. Since the CPP control circuit changes the propeller angle with the voltage difference input, it has a design structure that can be vulnerable if the input voltage fluctuates instantaneously. In order to solve the above problem, a terminating resistor is applied to the end of the control wire and a signal converter is applied between the control wires, as a way to improve the CPP control circuit design. In order to verify that there is no problem in improving the CPP control circuit design, the CPP pitch change control was tested in the actual sailing commissioning with LST-II. Since the command pitch value and the feedback pitch value are very similar to each other, it is confirmed that the CPP control circuit is suitable for the control signal transmission because there is no problem in transmitting the control signal.

A Study on the Design of the Carrier Phase Difference for the Planetary Gear Noise Reduction (유성기어 소음저감을 위한 캐리어 위상차 설계에 관한 연구)

  • Park, Ki-Ho;Kim, Tai-Hoon;Jung, Sang-Jin;Wee, Hyuk;Lee, Gook-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.230-231
    • /
    • 2011
  • There is a merit a planetary gear set disperses a delivery load, and to decrease loss of friction and noise. But, in addition to meshing this internal and external gear simultaneously and phase difference by the tooth contact point and the time difference occurs asymmetric and symmetric sideband noise and vibration caused by the modulation in the vehicle. Existing planetary gear set research have progressed to reduce the cause of the sideband as run-out, pitch error and imbalance. In this paper presents a method for the design of the carrier phase difference by developing various theorys and experiments for gear noise.

  • PDF

An analysis of the thermal characteristics for optimal design and operation of the radiant heating panels (복사난방패널의 설계 및 운전을 위한 열적 특성 분석)

  • Lee, T.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.180-188
    • /
    • 1997
  • The theoretical analysis and experiment with simulator were performed to obtain the temperature distributions in radiant heating panel and heat supply from hot water to heating space for the purpose of the development of comfortable living space from a point of view of the improvement of air quality and the enhancement of system efficiency. The relations of various parameters, such as pipe pitch, room temperature as well as flow rate and temperature of hot water and so on, with the rate of heat supplied, mean temperature and maximum temperature difference at panel surface were discussed. The effects of these parameters were also verified on the thermal performance of heating panel using the relations which could be used for the optimal design and operation of the radiant heating panel.

  • PDF

Z-axis Contact Detection Algorithm for a Wire Bonder using a Discrete Kalman Filter

  • Kim, Jung-Han
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.52-58
    • /
    • 2007
  • We propose a new contact detection algorithm for fine pitch wire bonding. Fast and stable contact detection of the z-axis in wire bonding is extremely important to maintain the quality of fine pitch gold wire bonding processes, which use a small pad less than $70{\mu}m$ in diameter. A small perturbation in the contact detection time causes a large difference in the size of the formed squashed ball. The new detection method is based on a statistical approach and designed for a discrete Kalman filter. It is faster and has smaller detection time variations than conventional detection methods. Experimental results are presented to demonstrate the advantages of the proposed algorithm.

An Analysis of Phonetic Parameters for Individual Speakers (개별화자 음성의 특징 파라미터 분석)

  • Ko, Do-Heung
    • Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.177-189
    • /
    • 2000
  • This paper investigates how individual speakers' speech can be distinguished using acoustic parameters such as amplitude, pitch, and formant frequencies. Word samples from fifteen male speakers in their 20's in three different regions were recorded in two different modes (i.e., casual and clear speech) in quiet settings, and were analyzed with a Praat macro scrip. In order to determine individual speakers' acoustical values, the total duration of voicing segments was measured in five different timepoints. Results showed that a high correlation coefficient between $F_1\;and\;F_2$ in formant frequency was found among the speakers although there was little correlation coefficient between amplitude and pitch. Statistical grouping shows that individual speakers' voices were not reflected in regional dialects for both casual and clear speech. In addition, the difference of maximum and minimum in amplitude was about 10 dB which indicates a perceptually audible degree. These acoustic data can give some meaningful guidelines for implementing algorithms of speaker identification and speaker verification.

  • PDF

Position Accuracy Error Analysis in 2 Phase 8 Pole HB Type LPM (2상 8극 HB형 LPM의 위치오차 해석)

  • Kim, Sung-Hun;Lee, Eun-Woong;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.38-41
    • /
    • 1997
  • As the LPM is used for position accuracy decision device it is required that both the reason of posion error and the definition of position itself should be cleared. In this study, the precision of the position decision of LPM is affected by the geometrical shape such as tooth shape or processing accuracy. By using the analysis of magnetic circuit, we calculated the permeance come up with the gap. Once the thrust force has been obtained, the permeance due to the mechanical error of the pole pitch and the tooth pitch becomes the error of thrust force. We confirmed as well that it is being affected by the difference due to the variation of the airgap permeance.

  • PDF

Performance evaluation of PF-condenser adapted to Large Size air-conditioner (대형 에어컨에 적용된 PF열교환기의 성능평가)

  • Cho, J.P.;Choi, Y.H.;Kim, J.H.;Kim, N.H.;Kim, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.1-6
    • /
    • 2000
  • In this study, We evaluated the Performance of PFC and the system performance of large size air-conditioner applying to outdoor condenser. PFC can meet the same cooling capacity in 40.42% of volume to fin-tube condenser. Although the fin-tube condenser requires 3600g of refrigerant charging, PFC requires 1700g, 1800g, 1900g, 2000g refrigerant charging for each 2.0mm, 2.5mm, 3.0mm and 3.5mm fin pitches. Difference of condensing and evaporation pressure is the biggest point 2.0mm fin pitch and the smallest point 2.5mm fin pitch.

  • PDF

Application of Forced Oscillation Technique for Pitch Dynamic Stability Derivatives of a Missile Model (미사일 모델의 피치 동안정미계수 측정을 위한 강제진동기법의 적용)

  • 김승필;조환기;백승욱
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • This paper presents an application of forced oscillation technique to measure pitch dynamic stability derivatives of a missile model in the low speed wind tunnel. The missile model is oscillated by D.C. electric servomotor with constant amplitudes and frequencies. Phase shift is determined as the difference of peak values between input and output signals from the dynamic stability balance installed at the center of gravity of the model. Stability derivatives were calculated by using phase shifts, amplitudes, forcing moments and input frequencies. Test results show the proper usage of the force oscillation technique with good damping effects.

  • PDF