• Title/Summary/Keyword: piping

Search Result 1,574, Processing Time 0.033 seconds

A Study on Relationship of Flow coefficient and Valve Type for Design of Butterfly Valve (버터플라이 밸브 설계를 위한 밸브 형과 유량 계수와의 관계)

  • Oh, Seung-Hwan;Lee, Young-Hun;Kang, Hyeung-Geol;Song, Hak-Guan;Kang, Jung-Ho;Park, Young-Chul
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.49-53
    • /
    • 2007
  • The valve is used on control of flow in a ship. Flow coefficient of valve is very importance in the design of valve. In this paper, three-dimensional computer simulations by commercial code CFX were conducted to observe the valve type and to measure flow coefficient when valves with various angles and uniform incoming velocity were used in a piping system. By contrast, a group of experimental data is used to compare with the data obtained by CFX simulation to investigate the validity of numerical method.

Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire (터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구)

  • Park, Hyung-Joo;Choi, Young-Sang;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

Flow Rate Control System Design for the Industrial Valve (산업용 밸브의 유량제어 시스템 설계)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.387-392
    • /
    • 2020
  • This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.

A Study on the cleansing of water data using LSTM algorithm (LSTM 알고리즘을 이용한 수도데이터 정제기법)

  • Yoo, Gi Hyun;Kim, Jong Rib;Shin, Gang Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.501-503
    • /
    • 2017
  • In the water sector, various data such as flow rate, pressure, water quality and water level are collected during the whole process of water purification plant and piping system. The collected data is stored in each water treatment plant's DB, and the collected data are combined in the regional DB and finally stored in the database server of the head office of the Korea Water Resources Corporation. Various abnormal data can be generated when a measuring instrument measures data or data is communicated over various processes, and it can be classified into missing data and wrong data. The cause of each abnormal data is different. Therefore, there is a difference in the method of detecting the wrong side and the missing side data, but the method of cleansing the data is the same. In this study, a program that can automatically refine missing or wrong data by applying deep learning LSTM (Long Short Term Memory) algorithm will be studied.

  • PDF

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

CONCEPTUAL DESIGN OF THE SODIUM-COOLED FAST REACTOR KALIMER-600

  • Hahn, Do-Hee;Kim, Yeong-Il;Lee, Chan-Bock;Kim, Seong-O;Lee, Jae-Han;Lee, Yong-Bum;Kim, Byung-Ho;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.193-206
    • /
    • 2007
  • The Korea Atomic Energy Research Institute has developed an advanced fast reactor concept, KALIMER-600, which satisfies the Generation IV reactor design goals of sustainability, economics, safety, and proliferation resistance. The concept enables an efficient utilization of uranium resources and a reduction of the radioactive waste. The core design has been developed with a strong emphasis on proliferation resistance by adopting a single enrichment fuel without blanket assemblies. In addition, a passive residual heat removal system, shortened intermediate heat-transport system piping and seismic isolation have been realized in the reactor system design as enhancements to its safety and economics. The inherent safety characteristics of the KALIMER-600 design have been confirmed by a safety analysis of its bounding events. Research on important thermal-hydraulic phenomena and sensing technologies were performed to support the design study. The integrity of the reactor head against creep fatigue was confirmed using a CFD method, and a model for density-wave instability in a helical-coiled steam generator was developed. Gas entrainment on an agitating pool surface was investigated and an experimental correlation on a critical entrainment condition was obtained. An experimental study on sodium-water reactions was also performed to validate the developed SELPSTA code, which predicts the data accurately. An acoustic leak detection method utilizing a neural network and signal processing units were developed and applied successfully for the detection of a signal up to a noise level of -20 dB. Waveguide sensor visualization technology is being developed to inspect the reactor internals and fuel subassemblies. These research and developmental efforts contribute significantly to enhance the safety, economics, and efficiency of the KALIMER-600 design concept.

Study of Sewage Treatment using Multi-soil-layering System (다단토양층을 이용한 하수처리에 관한 연구)

  • Son, Dae-Hee;Chung, Yun-Chul;Shin, Jeong-Hoon;Jung, Jin-Young;Ahn, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.

Structural Integrity Evaluation of Large Main Steam Piping by Water Hammering (수격 현상에 근거한 대형 주증기관의 구조건전성 평가)

  • Jo, Jong-Hyun;Lee, Young-Shin;Kim, Yeon-Whan;Jin, Hai Lan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1103-1108
    • /
    • 2012
  • A main steam pipe system is a branch pipe that connects a boiler with a turbine. Water hammering analysis is very important for limiting the damage caused to pipe systems by operation conditions. Water hammering created by an unsteady flow in pipeline systems can cause excessive change in pressure, vibration, and noise. The main steam pipe structure should be designed to safely maintain the pressure pulsation and several vibrations under operation environments. This study evaluated the structural integrity of a main steam pipe during suspended and normal operation by using the ASME fatigue life methodology and finite element analysis. In the analysis, water hammering was used for transient analysis. The calculated alternating stress and fatigue stress were compared with the applicable limits of ASME fatigue life. All the evaluation results satisfied the requirements of the ASME fatigue life.

Round Robin Test for Performance Demonstration System of Ultrasonic Examination Personnel (초음파검사자 기량검증 체제를 위한 다자비교시험)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Ho;Kim, Yong-Sik;Yang, Dong-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.378-383
    • /
    • 2004
  • The Korean Performance Demonstration(KPD) System for the ultrasonic testing personnel, equipments and procedures applicable to the Class 1 and 2 piping examination for nuclear power plant in Korea has been established. A round robin test was conducted in order to compare the examination results by the method of Performance Demonstration(PD) with the traditional dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, adoption of the PD method to the in-service inspection of the nuclear power plants will improve the reliability of the ultrasonic test results.