• 제목/요약/키워드: pipe-in-pipe

검색결과 5,763건 처리시간 0.032초

크랙을 가진 유체유동 회전 외팔 파이프의 안정성 해석 (Stability Analysis of Rotating Cantilever Pipe Conveying Fluid with Crack)

  • 손인수;윤한익;김동진
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1161-1169
    • /
    • 2007
  • In this paper, the dynamic stability of a rotating cantilever pipe conveying fluid with a crack is investigated by the numerical method. That is, the influence of the rotating angular velocity, mass ratio and crack severity on the critical flow velocity for flutter instability of system are studied. The equations of motion of rotating cantilever pipe are derived by using extended Hamilton's principle. The crack section of pipe is represented by a local flexibility matrix connecting two undamaged pipe segments. The crack is assumed to be in the first mode of fracture and always opened during the vibrations. Generally, the critical flow velocity for flutter is proportional to the rotating angular velocity of a pipe. Also, the critical flow velocity and stability maps of the rotating pipe system for the variation each parameter are obtained.

Explicit Design of Uniformly Rough Pipe

  • Yoo, Dong-Hoon
    • Korean Journal of Hydrosciences
    • /
    • 제7권
    • /
    • pp.107-124
    • /
    • 1996
  • Pipe design normally requires pump power, discharge or pipe diameter for each condition given. Due to several investigators the pipe friction factor con now be estimated by explicit way for a wide range of flow condition. In various problems of pipe design, however, the flow condition cannot be pre-determined even for a uniformly rough pipe. In these cases a lot of iterations are often required to have an accurate solution with ordinary approach. This paper presents the direct computation method of discharge and pipe diameter without any iteration process. Introducing the power law of friction factor, various non-dimensional physical numbers are derived such as power-diameter number, power-discharge number, diameter-slope number and discharge-slope number. One of the physical numbers concerned with discharge or pipe diameter can be related to a combination of the other in an explicit way.

  • PDF

Stress evaluation method of reinforced wall-thinned Class 2/3 nuclear pipes for structural integrity assessment

  • Jae-Yoon Kim;Je-Hoon Jang;Jin-Ha Hwang;Yun-Jae Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1320-1329
    • /
    • 2024
  • When wall-thinning occurs in nuclear Class 2 and 3 pipes, reinforcement is typically applied rather than replacement. To analyze the structural integrity of reinforced wall-thinned pipe, stress analysis results using full 3-D FE analysis are not compatible to the design code equation, ASME BPVC Sec. III NC/ND-3650. Therefore, the efficient stress evaluation method for the reinforced wall-thinned pipe, compatible to the design code equation, needs to be developed. In this paper, stress evaluation methods for the reinforced wall-thinned pipe are proposed using the equivalent straight pipe concept. Furthermore, for fatigue analysis of the reinforced wall-thinned pipe, the stress intensification factor of reinforced wall-thinned pipe is presented using the structural stress method given in ASME BPVC Sec. VIII Div.2.

이동질량과 등분포접선종동력이 외팔보의 동특성에 미치는 영향 (The Influence of Moving Masses on Dynamic Behavior of a Cantilever Pipe Subuected to Uniformly Distributed Follower Forces)

  • 손인수;윤한익;김현수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.80-85
    • /
    • 2002
  • A conveying fluid cantilever pipe system subjected to an uniformly distributed tangential follower force and three moving masses upon it constitute this vibrational system. The influences of the velocities of moving masses, the distance between two moving masses. and the uniformly distributed tangential follower force have been studied on the dynamic behavior of a cantilever pipe system by numerical mettled. The uniformly distributed tangential follower force is considered within its ciritical value of a cantilever pipe without moving masses, and three constant velocities and three constant distance between two moving masses are also chosen. When the moving masses exist on pipe, As the velocity of the moving mass and distributed tangental force increases, the deflection of cantilever pipe conveying fluid is decreased, respectively. Increasing of the velocity of fluid flow make the amplitude of cantilever pipe conveying fluid decrease. After the moving mass passed upon the pipe, the tip displacement of pipe is influenced by the potential energy of cantilever pipe.

  • PDF

이동질량들을 가진 단순지지된 유체유동 파이프의 동특성 (Dynamic Behavior of a Simply Supported Fluid Flow Pipe with Moving Masses)

  • 윤한익;임순홍
    • 한국소음진동공학회논문집
    • /
    • 제12권2호
    • /
    • pp.132-140
    • /
    • 2002
  • A simply supported pipe conveying fluid and the moving masses upon it constitute this vibrational system. The equation of motion is derived by using Lagrange's equation. The influence of the velocity and the inertia force of the moving masses and the velocities of fluid flow in the pipe have been studied on the dynamic behavior of a simply supported pipw by numerical method. The velocities of fluid flow are considered within its critical values of the simply supported pipe without the moving masses upon it. Their coupling effects on the transverse vibration of a simply supported pipe are inspected too. The dynamic deflection of the simply supported pipe conveying fluid is increased by a coupling of the moving masses and the velocities of the moving masses and the fluid flow. When four or five regular interval masses move on the simply supported pipe conveying fluid, the amplitude of the simply supported pipe conveying fluid is small at low velocity of the masses, but at high velocity of the masses the deflection of midspan of the pipe is increased by coupling with the numbers and magnitude of the masses. The time which produce the maximum dynamic deflection of the simply supported pipe is delayed according to the increment of the number of moving masses.

Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가 (Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers)

  • 방승기;안혜린
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

유체 분사 추진력을 받는 배관 휩 구속장치 거동에 관한 유한요소해석 (Finite Element Analysis of Pipe Whip Restraint Behavior Under Jet Thrust Forces)

  • Sugoong Koh;Lee, Young-Shin
    • Nuclear Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.353-360
    • /
    • 1993
  • 원자력 발전소에서는 고에너지배관이 파단되는 가상 배관 휩 현상으로부터 구조물을 보호하기 위하여 많은 종류의 배관 휩 구속장치(Pipe Whip Restraint, PWR)가 설치되어 있다. 이 배관 휩 구속장치를 보다 합당하게 설계하거나 배관 휩 구속장치의 설계타당성을 평가하기 위하여 배관 휩 현상을 자세히 관찰하는 것이 필요하다. 이와 같은 이유로 배관 휩 현상을 해석하는 방법 개발자 개발된 방법의 타당성을 입증하기 위한 다양한 연구 프로그램이 여러나라에서 수행되어 왔다. 본 연구에서는 배관 휩 구속장치에 가해지는 충격하중을 계산하기 위해 범용 유한요소 전산 프로그램인 ANSYS내의 여러 형태의 유한요소들을 이용하여 가상 배관 휩 현상을 모의했으며 계산 결과는 U자형 배관 휩 구속장치를 갖는 배관계통의 배관 휩 모의시험으로부터 구해진 대상 실험 결과와 비교, 검토되었다. 배관 휩 구속장치와 배관 사이의 갭요소나 스프링요소를 갖는 계산모델의 일부는 해당 실험결과와 비교해 볼 때 배관 휩 구속장치에 걸리는 인장력을 사고기간 동안에 잘 모의함을 보여서 배관 휩 구속장치의 설계타당성을 평가하는데 유용 할 것으로 판단된다.

  • PDF

상변화 물질을 조합한 히트파이프의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of a Heat Pipe Combined with PCM)

  • 박영학;정의국;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2119-2123
    • /
    • 2007
  • This study deals with performance characteristics of heat pipe combined with a solid-liquid phase change material(PCM). The outer diameter of the heat pipe was 9.5 mm and the total length was 600 mm, where the evaporator, the adiabatic section and the condenser lengths were equally 200 mm. A paraffin wax having a melting point of 58.5$^{\circ}C$ was used as PCM. The paraffin container was attached to the adiabatic section of the heat pipe. The paraffin container had outer diameter of 18 mm, wall thickness of 1.2 mm and the total length of 100 mm. The heat pipe was tested with tilt angle of horizontal degree and favorite angle 10 degree, with evaporator lower position to provide stable operation of the heat pipe. Input thermal load was varied from 40 W, with increment of 40 W, to above 100 W until the maximum temperature of the heat pipe wall reached 200$^{\circ}C$. Test results of the PCM heat pipe were presented in comparison with conventional heat pipe of the same basic dimensions. The performance was analyzed in terms of temperature distribution, thermal resistance and heat transport capability.

  • PDF

배관실험을 통한 국부감육 배관의 손상거동 평가 (An Evaluation of Failure Behavior of Pipe with Local Wall Thinning by Pipe Experiment)

  • 김진원;박치용
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.731-738
    • /
    • 2002
  • To understand failure behavior of pipe thinned by flow accelerated corrosion, in this study, the pipe failure tests were performed on 102mm-Sch.80 carbon steel pipe with various local wall thinning shapes, and the failure mode, load carrying capacity, and deformability were investigated. The tests were conducted under loading conditions of 4-points bending and internal pressure. The experimental results showed that the failure mode of thinned pipe depended on magnitude of internal pressure and thinning length as well as loading direction and thinning depth and angle. The variation in load carrying capacity and deformability of thinned pipe with thinning length was determined by stress type appled to the thinning area and circumferential thinning angle. Also, the effect of internal pressure on failure behavior was dependent on failure mode of thinned pipe, and it promoted crack occurrence and mitigated local buckling at thinned area.

진동절연을 위한 에어컨 압축기의 파이프 배열기술 개발 (Development of Pipe configuration of Air Conditioner Compressor for Vibration Isolation)

  • 장한기;구치욱;윤덕원;최영훈
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.795-805
    • /
    • 1999
  • Rubber mounts so called grommets and pipes are two major paths of vibration transmission from a compressor, an important vibration source in an air conditioner, to the whole unit. A procedure of configuring the suction and discharge pipes of the compressor was developed in this paper so as to reduce the vibration transmission through the pipes as well as the grommets. Through investigating the effects of shapes and connecting disrections of pipe elements on vibration transmission, a guideline to configure the pipe layout, which enables to reduce vibration transmission, was proposed. The initial pipe layout by the guideline was optimized with the objective function, minimization of boty vibration transmission and the cost, and with the constraints to yield the final dimensions of the pipes. The procedure not only minimizes the transmitted force to the circumferential devices but enables to eliminate rubber blocks or dampers, which are generally used to avoid resonances of the pipe system.

  • PDF