• 제목/요약/키워드: pipe test

검색결과 1,229건 처리시간 0.022초

재사용 파이프서포트의 내력변화 연구 (1) (A Study on the Strength Change of Used Pipe Support (1))

  • 백신원;노민래
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.93-97
    • /
    • 2004
  • Slab formwork consists of sheathing, stringer, hanger and shore. There are several types of adjustable individual shores. In constructions site, pipe supports are usually used as shores. The strength of a pipe support is decreasing as it is frequently being used at the construction site. In this study, 2857 pipe supports were bought to fine out the strength change of used pipe support and unused pipe supports according to aging. Among these pipe supports, 2337 pipe supports were lent to the construction companies free of charge. Compressive strength was measured by knife edge test and plate test at each 3 month. Test results show that the strength of unused pipe supports almost equaled to the strength of new pipe supports until 191 days, but the strength of used pipe supports at 191 days was lower than the strength of new pipe supports. So, the strength of used pipe supports at 191 days was not satisfied the specification of KS F 8001. According to these results, it shows that attention has to be paid to formwork design using used pipe supports. Therefore, the paresent study results will be able to provide a firm base to design slab formwork and test the performance of used temporary structure and prevent formwork collapses.

차량 연료공급용 파이프 및 시험용 지그의 진동특성 해석 (Analysis of Vibration Characteristics of Fuel Pipe and Test Jig for Vehicle)

  • 손인수;김명수
    • 한국산업융합학회 논문집
    • /
    • 제24권3호
    • /
    • pp.315-321
    • /
    • 2021
  • In this study, the natural frequency analysis of the fuel pipe and vibration test jig was performed as a basic study to determine the vibration characteristics of the vehicle's fuel pipe and the stability analysis of fatigue failure of the pipe. The natural frequencies of the fuel pipe and the fuel pipe with the test jig were calculated and the results were compared. As a result of the analysis, it was found that the natural frequency of the fuel pipe and the natural frequency of the test jig differed about 7 times, so that the vibration of the test jig did not affect the vibration of the fuel pipe. In addition, as a result of the natural frequency analysis of the fuel pipe itself and the pipe with the test jig attached, the maximum error is less than about 1%. In the future, it was suggested that the analysis of the design changed fuel pipe may be performed without a test jig.

진동 및 전압 철근 콘크리트관의 종.횡단배수관 적용성 검토에 관한 연구 (Study on the possible application of Vibrated and Rolled reinforced concrete pipe to vertical.crossing water distribution system)

  • 박도경;이명규;양극영
    • 한국건축시공학회지
    • /
    • 제6권2호
    • /
    • pp.111-117
    • /
    • 2006
  • In case of carrying out vortical crossing water distribution system in expressways or general roads construction, VR(Vibrated and Rolled reinforced concrete) pipes are restricted because of their specification of reinforced spun concrete pipe or on-site made pipe. Therefore, in order to apply VR pipes to those constructions, through the structural behavior experiments of the pipes, VR pipes are compared and verified with reinforced spun concrete pipe and the results are obtained as the following. From the experiments and analyses of Pipe Stiffness(PS) of the pipes, cracking loading is approved to satisfy the KS regulations. Through a direct load test, the cracking loading strength and the maximum load test of VR pipe is larger compared with reinforced spun concrete pipe. Particularly, even if side weld is thin, there is no little change in the cracking strength of VR pipe. The results of the direct load test analysis show that the structural behavior of VR pipe is equivalent or higher compared with reinforced spun concrete pipe in performance and VR pipe could be used as the water distribution pipe for roads. In this study, through pipe stiffness, direct load test and load teat on earth, reinforced spun concrete pipe and VR pipe are compared. And as a result, the structural behavior of VR pipe is comprehensively excellent. From the structural behavior tests, VR pipe's section shows more thickness and has uniform characteristics so that VR pipe is considered more favorable than reinforced spun concrete pipe.

재사용 파이프서포트의 내력변화 연구(III) (A Study on the Strength Change of Used Pipe Support(III))

  • 백신원;최순주
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.101-106
    • /
    • 2006
  • Formwork is a temporary structure that supports its weight and that of freshly placed concrete as well as construction live loads. In constructions site, pipe supports are usually used as shores which are consisted of the slab formwork. The strength of a pipe support is decreasing as it is frequently being used at the construction site. Among the accidents and failures that occur during concrete construction, there are many formwork failures which usually happen at the time concrete is being placed. The objective of this study is to find out the strength change of used pipe support and unused pipe supports according to aging. In this study, 2857 pipe supports were prepared. Among these pipe supports, 2337 pipe supports were lent to the construction companies free of charge. 520 pipe supports were kept on the outside. Compressive strength was measured by knife edge test and plate test at each 3 month. Test results show that the strength of unused pipe supports as well as used pipe supports was decreasing according to age, use frequency and load carrier, and the strength of used pipe supports was lower than the strength of unused pipe supports at the same age. So, the strength of used pipe supports from 191 days to present day was not satisfied the specification of KS F 8001. In this study, the strength of pipe support according to age, use frequency and load carrier was predicted using SPSS 12.0. It was known that the strength of pipe support using for 5 years was reduced to 42.8%. According to these results, it shows that attention has to be paid to formwork design using used pipe supports. Therefore, the present study results will be able to provide a finn base to prevent formwork collapses.

재사용 파이프서포트의 내력변화 연구 (A study on the strength Change of Used Pipe Support)

  • 백신원;최순주
    • 건설안전기술
    • /
    • 통권38호
    • /
    • pp.79-87
    • /
    • 2006
  • Formwork is a temporary structure that supports its weight and that of freshly placed concrete as well as construction live loads. In constructions site, pipe supports are usually used as shores which are consisted of the stab formwork. The strength of a pipe support is decreasing as it is frequently being used at the construction site. Among the accidents and failures that occur during concrete construction, there are many formwork failures which usually happen at the time concrete is being placed. The objective of this study is to find out the strength change of used pipe support and unused pipe supports according to aging. In this study, 2857 pipe supports were prepared. Among these pipe supports, 2337 pipe supports were lent to the construction companies free of charge. 520 pipe supports were kept on the outside. Compressive strength was measured by knife edge test and plate test at each 3 month. Test results show that the strength of unused pipe supports as well as used pipe supports was decreasing according to age, use frequency and load carrier, and the strength of used pipe supports was lower than the strength of unused pipe supports at the same age. So, the strength of used pipe supports from 191 days to present day was not satisfied the specification of KSF 8001. In this study, the strength of pipe support according to age, use frequency and load carrier was predicted using SPSS 12.0. It was known that the strength of pipe support using for 5 years was reduced to 42.8%. According to these results, it shows that attention has to be paid to formwork design using used pipe supports. Therefore, the present study results will be able to provide a firm base to prevent formwork collapses.

  • PDF

구조해석에 의한 파이프서포트의 내력비교에 관한 연구 (A Study on the Strength Comparison of Steel Pipe Support using the Structural Analysis Program)

  • 백신원;박종근
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.67-71
    • /
    • 2008
  • Formwork is a temporary structure that supports its weight and that of fresh concrete as well as construction live loads. Slab formwork consists of sheathing, stringer, hanger and shore. In construction site, pipe supports are usually used as shores which are consisted of the slab formwork. In this study, compressive strength of 80 pipe supports was measured by knife edge test and plate test. Buckling load of pipe supports was analyzed by structural analysis program(MlDAS). Theoretical buckling load with/without initial deformation was got by theoretical analysis. According to these results, buckling load which was analyzed by structural analysis program(MlDAS) was larger than compressive strength of knife edge test and plate test. Theoretical buckling load without initial deformation was larger than compressive strength of knife edge test and plate test. But Theoretical buckling load with initial deformation was lower than compressive strength of knife edge test and plate test. Initial deformation equation for test method according to the pipe support length was suggested. Therefore, the present study results will be used to design the slab formwork safely.

재사용 파이프서포트의 내력변화 연구(II) (A Study on the Strength Change of Used Pipe Support(II))

  • 백신원;노민래
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.120-125
    • /
    • 2005
  • Formwork is a temporary structure that supports its weight and that of freshly placed concrete as well as construction live loads. Among the accidents and failures that occur during concrete construction, many are formwork failures which usually happen at the time concrete is being placed. In constructions site, pipe supports are usually used as shores which are consisted of the slab formwork. The strength of a pipe support is decreasing as it is frequently being used at the construction site. The objective of this study is to find out the strength change of used pipe support and unused pipe supports according to aging. In this study, 2857 pipe supports were prepared. Among these pipe supports, 2337 pipe supports were lent to the construction companies fire of charge. 520 pipe supports were kept on the outside. Compressive strength was measured by knife edge test and plate test at each 3 month. Test results show that the strength of unused pipe supports as well as used pipe supports was decreasing according to age, use frequency and load carrier, and the strength of used pipe supports was lower than the strength of unused pipe supports at the same age. So, the strength of used pipe supports from 191 days to present day was not satisfied the specification of KS F 8001. According to these results, it shows that attention has to be paid to formwork design using used pipe supports. Therefore, the present study results will be able to provide a firm base to prevent formwork collapses.

PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구 (An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service)

  • 박정화;오천영;곽지현;손봉세
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.55-61
    • /
    • 2016
  • 본 연구는 현재 사용하고 있는 소방용 배관의 부식으로 인하여 발생하는 수계소화설비의 문제를 해결하기 위하여 개발한 Polyethylene (PE) 이종강관을 수계소화설비배관으로 적용할 수 있는지를 파악하기 위한 실제 화재시험을 수행하였다. 개발된 이종배관에 대한 관련시험기준이 없어 국내외 기술자료 및 시험기준을 비교분석하여 적합한 화재시험기준을 선정하여 PE 이종강관의 성능을 분석하였다. 따라서 본 배관의 성능시험에 채택한 화재시험기준은 합성수지배관과 금속배관의 두 가지의 화재시험기준을 적용하였고 총 6차례의 화재실험을 실시하여 배관성능을 평가하였다. 소방용합성수지배관의 시험기준을 적용한 1, 2차의 화재시험결과 이음쇠와 배관에서 파손이나 변형이 없었으며 5분간 내압시험을 실시한 결과에서도 누수가 없었다. 금속배관시험기준을 적용한 화재실험은 총 4회를 실시하였으며 1, 2차 실험은 습식설비를 모사한 것으로 화재시험결과는 PE 이종강관에서 누설이나 파열이 발생하지 않았으며 또한 PE 재질의 이탈 등 손상이 발생되지 않음을 확인하였다. 단, 건식설비를 모사한 3, 4차의 화재시험결과 소화수가 방출되기 이전에 PE 이종강관에서 파열, 변형 등의 손상이 발생하였다. 따라서 실험결과 습식설비를 모사한 화재시험의 경우 PE 이종강관의 융착성, 변형, 파손 등 배관의 성능에 이상이 없음을 확인하였다.

내부 아터리가 있는 알루미늄 그루브 히트파이프와 써모사이펀의 작동특성에 관한 실험적 연구 (Experimental Study on the Working Characteristic of Aluminum Grooved Heat Pipe and Thermosyphon with Inner Arterial Wick)

  • 홍진관;김대성;정원복
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.894-900
    • /
    • 2000
  • The experimental study for performance improvement of aluminum/freon22 grooved heat pipe was carried out. Arterial wick was used for performance improvement of heat pipe. The experimental result was compared with screen covered grooved wick heat pipe. And also, performance test of grooved wick thermosyphon inserted straight wire in the center of grooved pipe was carried out. This result was compared with the performance test result of grooved wick thermosyphon. The operation limit of artery inserted grooved heat pipe was slightly extended, but thermal resistance of this heat pipe was twice as large as that of screen covered grooved heat pipe. In case of thermosyphon, the operation limit of grooved thermosyphon inserted straight wire in the center of grooved pipe was slightly extended, but thermal resistance was increased, comparing with that of the grooved thermosyphon.

  • PDF

도시가스용 D3507 및 D3631 강관의 파괴특성 (Fracture Characteristics of D 3507 and D 3631 City Gas Steel Pipes)

  • 박재학;김한국;신규인;김만원
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 2001
  • It is noted that KS D 3507 pipe steel has several problems when it is used as a city gas pipe at medium pressure. So new pipe steel, KS D 3631, was developed in order to be used as a pipe for medium and low pressure and now it is being substituted for D 3507. In this study, several mechanical tests, such as tensile test, microhardness test, and Charpy impact test were conducted to get material properties of D 3507 and D 3631 pipe steels. And also microstructures at the weld and heat affected zones were observed for the two materials. From the Charpy test results $K_{IC}/$ was estimated for the upper and lower shelf and the critical crack length is calculated for supposed axial semi-elliptical surface cracks. And the burst pressure is estimated as a function of wear depth for a defective D 3631 pipe by using the finite element method. The burst pressure is also calculated for pipes with an axial crack by using the published equations.

  • PDF