• Title/Summary/Keyword: pipe - houses

Search Result 42, Processing Time 0.021 seconds

Appropriateness Evaluation of Rural House Collapse Prepare Disaster Shelter Member - Focusing on the Numerical Analysis - (농촌 주택붕괴 대비 방재쉘터의 부재 적정성 평가 - 수치해석을 중심으로 -)

  • Oh, Hyeonmun;Kim, Jungmeyon;Lee, Eungbeom;Lim, Changsu;Kim, Yongseong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.51-60
    • /
    • 2017
  • This research is a basic study to minimize the risk of disaster (earthquakes and landslides) for rural residential houses. In this study, three-dimensional numerical analysis was performed by varying the diameter (D), thickness (T) and the spacing of longitudinal members (C.T.C) of duralumin and galvanized steel pipe as the materials of main members in order to carry out the analysis of the dimension and the applied load of shelter for disaster prevention, and to evaluate the eligibility of members that can satisfy safety and usability. From the evaluation results of the member eligibility by the above numerical analysis, it was found that duralumin has a great influence on the member diameter (D) and thickness (T), and in the case of galvanized steel pipe, its spacing of longitudinal members has a huge amount of influence over the member force, so it is considered that the duralumin and galvanized steel pipe materials can be used as materials for the main members of disaster prevention shelters in terms of safety and usability.

A study on Development of Stress Tolerant Structural System in the Frame of Greenhouses (내재해성이 우수한 비닐하우스골조 구조시스템 개발에 관한 연구)

  • Shim, Jong-Seok;Lee, Choon-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.1
    • /
    • pp.5-13
    • /
    • 2012
  • The frame of pipe greenhouses in Korea have been collapsed increasingly due to very weak in structure caused by the heavy snow and strong wind. In order to reduce the collapse of green houses, it is urgent to develop the new structural system in stress tolerant greenhouses. Therefore, this paper performed the structural analysis of greenhouse frame in accordance with snow loads and wind loads. Three type models in structural frame configuration of greenhouses, that is, existing type, diagrid type, and honeycomb type are selected. It was classfied the section shape of structural frames in greenhouses into arch style, standard style, and diagonal standard style. As a result of this paper, it was verified that the structural system of diagrid type is better than that of existing type against snow loads and wind loads in the frame of greenhouses.

Investigation of Actural State of Plastic Greenhouse Structures in Korea (플라스틱 하우스의 구조 실태의 조사 연구)

  • 김문기;고재군;이신호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.3
    • /
    • pp.113-124
    • /
    • 1987
  • The objective of this study was to disclose the problem of structural safety and the state of utilization of standard types of plastic film house through investigation of actural state of plastic greenhouses for the southern part of the Korean peninsula. And also, the application method of standard types were proposed. The results obtained are summarized as follows 1. Plastic film houses investigated were not designed by the structural design conditions of loads and materials. 2.The construction method of greenhouses was not standardized. 3.Single type of standard greenhouses was nearly used and double types were applied to the standard type. 4.The standard frames of plastic film house were appeared to have structural lack of stability at the design snow and wind loads for most regions. 5.Safety snow depths and safety wind velocities were proposed for the frame intervals and pipe diameters of standard greenhouses.

  • PDF

Economic Assessment of Biomass Heating for Rural Application (바이오매스를 이용한 농업용 난방계획의 경제성 검토)

  • Hong, Seong-Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.45-52
    • /
    • 2005
  • Biomass is one of the most competitive renewable energy resource and can be used for heating for rural applications. A economic assessment was made of biomass heating, using the tool BIOH2000 from $RETScreen^{\circledR}$ International Clean Energy Decision Support Centre. For a 260kW heating system for 50 farm houses, the assessment showed a very promising results. Internal rate of return was $19.7\%$ and year-to-positive cash flow was 5.1 years. Relative price of biomass over fossil fuel significantly affected the economic feasibility of the project. Heating demand was directly related to annual demand of biomass and economic feasibility. Relative cost of distribution pipe over the total initial costs also affected the economic feasibility of the project. The economic feasibility was expected to be improved by the probable greenhouse emission reduction credit and reduction of initial costs through utilizing existing heating system for peak or back up heating system.

A Study on reduction plan of drainage noise for water closet (화장실 배수소음 저감 연구)

  • Lee, J.W.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.165-171
    • /
    • 2000
  • The study about a drainpipe of water closet was performed as reduction plan on drainage noise for water closet, which of noise in plumbing systems was being indicated the major point at issue in apartment houses. A drainpipe of water closet is divided into a sleeve, a joint elbow and a traversing pipe, through the result of experiment, for an effective noise reduction in a drainpipe a threefold joint elbow is proposed among parts. And through the experiment of performance with glasswool, the removal of glasswool should be in the economical efficiency aspect.

  • PDF

The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses (공동주택용 온수난방 시스템의 에너지해석 및 제어특성)

  • 장효환;안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

Performance Monitoring Study of Building Integrated Geothermal System in Winter (건물일체형 지열시스템의 동계 성능 모니터링 연구)

  • Yu, Hyung-Kyu;Bae, Sang-Hwan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The objective of this study is to develope ground heat exchanger using PHC pile used to building foundation, and it's element technology. So we made PHC piles into ground heat exchanger and evaluate it's performance. First, we studied PHC pile type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger. As a result we designed BIGS(Building Integrated Geothermal System) prototype. Second, we applied BIGS to apartment houses' utility building in Osan built by Daelim. Third, we monitored heating performance of winter season. 1be result of heating performance was so good to apply to heat & cooling system in building.

An Analysis on Development and Application of Solar Sunlighting Systems (첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구)

  • Kim, Jeong-Tai;Hwang, Min-Ku;Han, Bong-Soo
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.

Automatic Fire Extinguisher Having Flammable Pipes Inserted in a Cultural Assets Roof (가연성 파이프 시공에 의한 전통가옥지붕에 매설된 자동소화장치)

  • Cho, Taejun;Kim, Jae-Jun
    • The magazine of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.2
    • /
    • pp.26-31
    • /
    • 2014
  • This invention is purposed to provide an innovative solution for the inside of roof structures, which is cultural assets. The Asian old houses generally have several layered roofs on top of the structures. If a fire has started inside of the roof, it is hard to be extinguished before eliminating all the upper layers of the roof. This invention provides pre constructed embedded pipes, which is flammable and easy to be dissolved by the fire. The material of pipe is composed of rubbers, of which the combustion point is so low that the extinguishing of initial fire is possible without additional fire service. The inside of pipe is filled with halon gas. If the filled gas is consumed after ignited by fire, additional fire extinguishing water is supplied. If the flexible pipes are totally combusted by a big fire, the sprinkler at the end of inflexible pipe will work continuously, which is located between flexible and inflexible pipes. The extinguishing pipe network is suggested as dividing whole roof as multiple sections for a swift fire extinguishing in case of intentional or natural fire attack to our invaluable cultural assets.

  • PDF

The Corrosion Effect of the Water Pipelines in Buildings according to Drinking Water Quality (수돗물 수질에 따른 옥내급수관 부식에 미치는 영향분석)

  • Yu, Soon-Ju;Park, Su-Jeong;Ahn, Kyung-Hee;Kim, Hyun-Gu;Kim, Chang-Soo;Jung, Il-Rock;Park, Young-Bok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.701-708
    • /
    • 2008
  • As a countermeasure for reduction of corrosion in the delivery and distribution pipes used for tap water, materials for the pipelines in-houses and the effect of water quality on corrosivity of water pipelines were investigated in the distribution system of Han river. As the corrosion index at 6 water purification facilities of Han river, average Langelier Saturation Index (LI) of raw and finished water were -1.0 and -1.4 respectively and average Larson Index (LR) were 9.5 and 9.9, respectively. And also corrosion potential showed corrosivity in finished water (-431~-462 mV) as well as raw water (-426~-447 mV). This results indicate that tap water quality of han river have corrosivity. To understand the corrosivity effect in pipe material used for premise distribution system, water quality of stagnant tap water and tap water were analyzed and the differences between them were calculated. The difference concentration of iron, copper and zinc were $12.9{\mu}g/L$, $31.0{\mu}g/L$ and $45.0{\mu}g/L$ respectively in galvanized steel pipe for use more than 15 years and showed highest concentration. As a result, the control to corrosivity in the water pipelines, corrosivity control treatment in the water purification system can be applied. In advance it is necessary to monitor corrosivity of water quality using corrosive index because corrosivity may differ from the seasonal and regional characteristics and water chemicals dosage. For the future the guideline for corrosion index have to be established.