• Title/Summary/Keyword: pin support

Search Result 65, Processing Time 0.023 seconds

Torsional Rigidity of a Two-stage Cycloid Drive (이단 사이클로이드 드라이브의 비틀림 강성)

  • Kim, Kyoung-Hong;Lee, Chun-Se;Ahn, Hyeong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1217-1224
    • /
    • 2009
  • This paper presents a finite element (FE) analysis of the torsional rigidity of a two-stage cycloid drive. The cycloid disk makes contact with a number of pin-rollers simultaneously and eccentric shafts transmit not only torque of the spur gear stage to the cycloid disk, but also that of the cycloid disk to the output disk. Contacts between the disk and pin-rollers are simplified as linear spring elements, and the bearing of eccentric shaft is modeled as a rigid ring that has frictional contact to the disk and an elastic support. FE analysis for an ideal solid cycloid drive was performed and verified by a theoretical calculation. Accurate contact forces were then estimated by iterating between FE analysis for contact forces and Hertz theory calculations for nonlinear contact stiffness. In addition, torsional rigidity of the cycloid drive is analyzed to show that the bearing and nonlinear Hertz contact theory should be considered in analysis and design of a cycloid drive, which was verified with experiments. Finally, the effects of contact stiffness, bearing stiffness and cycloid disk structural stiffness according to the cycloid disk rotation on the torsional rigidity were investigated.

A Study on Application for Deck Plate Substitute Type Wood System Form of Frame Type Parking Lot (골조형 주차장의 Deck Plate 대체형 목제 시스템 거푸집 적용성 연구)

  • Shin, Yong-Jae;Shin, Woon-Sik;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.123-126
    • /
    • 2006
  • Existing Deck Plate for a one of system forms, there is various advantage and application actual results increasing rapidly. But design of deck is depending on engineering data collections or design data on deck manufacture ordinarily. When construct, is responsible for deflection occurrence, And Because confirmation of crack occurrence region is impossible, there is difficulty of repair, reinforcement about crack and water leakage. According to got following conclusion as result that economic performance, preservation administration and repair reinforcement develops easy using steel truss snap tie by wedge pin on coating plywood that is slab Panel Wood System Form method of construction there is Deck Plate's advantage. (1) In stab lower part is exposed disjointing in which a criminal is fastened to be interrogated after construction acceptance and repair, reinforcement of crack is possible (2) Construction cost curtailment effect of about 29.2% than conventional type and about 10% than deck plate (3) Construction period reduction of about 3 day than conventional type and about 0.3 day than deck plate (4) Labor curtailment effect more than about $29{\sim}50%$ from conventional type

  • PDF

A Study on Quality Management Improvement of Used Pipe Support(V2) (재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구)

  • Park, Jongkeun;Choi, Myeongki
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

A Study of Wireless LAN Communication using Embedded System (임베디드 시스템을 이용한 무선랜 통신에 관한 연구)

  • Lee, Chang-Keun;Choi, Jae-Woo;Ro, Bang-Hyun;Hwang, Hee-Yeung
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.673-676
    • /
    • 2003
  • In this paper, we designed the embedded system used for wireless LAN communication. Embedded system kernel is made from general linux kernel 2.4.18 by applying the ARM patch (2.4.18-rmk7) and the SA1100 patch(2.4.18-rmk7), then porting board level suitable to target system. The SA-1110 PCMCIA interface provides controls for one PCMCIA card slot with a PSKTSEL pin for support of a second slot. The embedded system requires external logic to complete the PCMCIA socket interface. For dual-voltage support, level shifting buffers are required for all SA-1110 input signals. Hot insertion capability requires that each socket be electrically isolated from each other, and from the remainder of the memory system. embedded system is for socket services approaching PCMCIA socket, detecting number of sockets, sensing insertion and removal, and applying power. It also provides interface with Card services. Embedded system supports Host driver for lucent chips that is installed orinoco driver cross compiled. The meaning can say that is doing wireless LAN communication through wireless LAN in imbedded system.

  • PDF

Boundary Conditions and Fire Behavior of Concrete Filled Tubular Composite Columns

  • Rodrigues, Joao Paulo C.;Correia, Antonio J.M.;Kodur, Venkatesh
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.313-325
    • /
    • 2018
  • Concrete-filled steel tubular (CFST) members are commonly used as composite columns in modern construction. However, the current guidelines for members' fire design (EN1994-1-2) have been proved to be unsafe in case the relative slenderness is higher than 0.5. In addition, the simplified design methods of Eurocode 4 are limited to circular and square CFST columns, while in practice columns with rectangular and elliptical hollow sections are being increasingly used because of their architectural aesthetics. In the last years a large experimental research has been carried out at Coimbra University on the topic. They have been tested concrete filled circular, square, rectangular and elliptical hollow columns with restrained thermal elongation. Some parameters such as the slenderness, the type of cross-section geometry as well as the axial and rotational restraint of the surrounding structure to the column have been tested in order to evaluate their influence on the fire resistance of such columns. In this paper it is evaluated the influence of the boundary conditions (pin-ended and semi-rigid end-support conditions) on the behavior of the columns in case of fire. In these tests it could not be seen a marked effect of the tested boundary conditions but it is believed that the increasing of rotational stiffness increases the fire resistance of the columns.

Ultimate Behavior of Compression Flange Stiffened by Shear Stud on Double Composite Steel Box Girder (이중합성 강박스거더에서 전단연결재에 의해 보강된 압축플랜지의 극한거동에 관한 연구)

  • Lee, Doo Sung;Lee, Sung Chul;Suh, Suk Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.457-463
    • /
    • 2008
  • The longitudinal stiffener performs its role to increase the local buckling strength by making simple support upon compression flange. In the recent researches, it is investigated that compression flange with point supports on certain arrangement reveals the same strength with longitudinal stiffeners. From this results, it is predictable that shear stud could perform the role of longitudinal stiffener if shear stud embedded in concrete satisfies the requirement to point-support under yield stress of the compression flange. In this study, the researches were performed to investigate the optimally required arrangement space of longitudinal point-support for which the shear stud replacing the longitudinal stiffeners and simultaneously determine the required numbers and space of shear stud for completely composite behavior between compression bottom flange and bottom concrete on the double composite girder system.

Application of 1mm fictitious notch radius approach to the fatigue strength assessment of welded joint (1mm 가상 노치 반경을 이용한 용접부 피로강도 평가에 관한 연구)

  • Kim Yu Il;Gang Jung Gyu;Heo Ju Ho
    • Proceedings of the KWS Conference
    • /
    • v.43
    • /
    • pp.275-277
    • /
    • 2004
  • Fictitious notch radius approach is based on the Neuter's microstructural support hypothesis which assumes that fatigue crack is governed by highly stressed volume of the material right on the weld toe area rather than the surface stress at a pin point of weld toe area. Variety of successes have been achieved in applying this methodology to the fatigue of welded joint, hence, it became one of recommended design procedure in IIW's recommendation as well as many ship classification societies. 1mm fictitious notch radius approach was applied to the various fatigue problems of welded joints in this study covering the effect of weld size, notch stress calculation for 3D geometry and low cycle fatigue problem. It was found that fictitious notch radius approach fumed out to be very effective and accurate in dealing with fatigue strength of welded joint.

  • PDF

Infilled frames: developments in the evaluation of cyclic behaviour under lateral loads

  • Cavaleri, L.;Fossetti, M.;Papia, M.
    • Structural Engineering and Mechanics
    • /
    • v.21 no.4
    • /
    • pp.469-494
    • /
    • 2005
  • In order to consider the modified seismic response of framed structures in the presence of masonry infills, proper models have to be formulated. Because of the complexity of the problem, a careful definition of an equivalent diagonal pin-jointed strut, able to represent the horizontal force-interstorey displacement cyclic law of the actual infill, may be a solution. In this connection the present paper, continuing a previous work in which a generalised criterion for the determination of the ideal cross-section of the equivalent strut was formulated, analizes some models known in literature for the prediction of the lateral cyclic behaviour discussing their field of validity. As a support of the discussion, the results of an experimental investigation involving single story-single bay infilled reinforced concrete. Frames under vertical and lateral loads with different kind of infill (actually not yet so much investigated) are presented. Finally, an improvement of a model known in the literature is proposed, taking the results of the experimental tests before mentioned into account.

A Study on the Development and Estimation of Waterproof Outlet for Low Voltage (저압용 방수 콘센트의 개발 및 평가에 관한 연구)

  • Choi, Chung-Seog;Kim, Chang-Soung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.181-185
    • /
    • 2008
  • In this paper, we investigates accident actual conditions of electric outlet for low voltage that is used into interior and clear hazardous factor. Electric outlet for general can know that melting of socket-outlet and carbonization of support occur if a contaminant becomes burnout because is flowed in. Existent outlet consists of structure that special quality is good but inflow of a contaminant is easy when is dry. But, waterproof outlet passes silicon layer and have connected structure plug. As developed outlet covers whole surface and back side, interval was shut. Safety pin of developed outlet was established to operate to vertical direction. Therefore, we estimate that contribute on prevention of electrical disaster if use developed outlet to a restaurant, a laundry, a laboratory etc.

A Study on Design of BIST for Circuits with Pipeline Architecture (파이프라인 구조를 갖는 회로를 위한 내장된 자체 검사 설계에 관한 연구)

  • Yang, Sun-Woong;Han, Jae-Cheon;Jin, Myung-Koo;Chang, Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.600-602
    • /
    • 1998
  • In this paper, we implement BIST to efficiently test circuits with pipeline architecture and JTAG to control implemented BIST and support board level test. Since implemented BIST is designed to be initialized using new seed, hard-to-detect faults are easily detected. Besides, to optimize area overhead, it uses JTAG instead of BIST controller and modified pipeline register instead of added test pattern generator and signature generator. And, to optimize pin overhead, it uses pins of JTAG. Function and efficiency of implemented BIST is verified by simulation.

  • PDF