• 제목/요약/키워드: pile shear

검색결과 311건 처리시간 0.022초

Flexural and shear behavior of large diameter PHC pile reinforced by rebar and infilled concrete

  • Bang, Jin-Wook;Lee, Bang-Yeon;Kim, Yun-Yong
    • Computers and Concrete
    • /
    • 제25권1호
    • /
    • pp.75-81
    • /
    • 2020
  • The purpose of this paper is to provide an experimental and analytical study on the reinforced large diameter pretensioned high strength concrete (R-LDPHC) pile. R-LDPHC pile was reinforced with infilled concrete, longitudinal, and transverse rebar to increase the flexural and shear strength of conventional large diameter PHC (LDPHC) pile without changing dimension of the pile. To evaluate the shear and flexural strength enhancement effects of R-LDPHC piles compared with conventional LDPHC pile, a two-point loading tests were conducted under simple supported conditions. Nonlinear analysis on the basis of the conventional layered sectional approach was also performed to evaluate effects of infilled concrete and longitudinal rebar on the flexural strength of conventional LDPHC pile. Moreover, ultimate strength design method was adopted to estimate the effect of transverse rebar and infilled concrete on the shear strength of a pile. The analytical results were compared with the results of the bending and shear test. Test results showed that the flexural strength and shear strength of R-LDPHC pile were increased by 2.3 times and 3.3 times compared to those of the conventional LDPHC pile, respectively. From the analytical study, it was found that the flexural strength and shear strength of R-LDPHC pile can be predicted by the analytical method by considering rebar and infilled concrete effects, and the average difference of flexural strength between experimental results and calculated result was 10.5% at the ultimate state.

Model verification and assessment of shear-flexure interaction in pile foundations

  • Lemnitzer, Anne;Nunez, Eduardo;Massone, Leonardo M.
    • Earthquakes and Structures
    • /
    • 제11권1호
    • /
    • pp.141-163
    • /
    • 2016
  • Fiber models have been developed and applied to various structural elements such as shear walls, beams and columns. Only scarcely have fiber models been applied to circular foundation systems such as cast in drilled holes shafts (CIDH). In pile foundations with constraint head boundary conditions, shear deformations can easily contribute to the lateral pile response. However, soil structure interaction formulations such as the p-y method, commonly used for lateral pile design, do not include structural shear deformations in its traditional derivation method. A fiber model that couples shear and axial-bending behavior, originally developed for wall elements was modified and validated on circular cross sections (columns) before being applied to a 0.61 m diameter reinforced concrete (RC) pile with fixed head boundary conditions. The analytical response was compared to measured test results of a fixed head test pile to investigate the possible impact of pile shear deformations on the displacement, shear, and moment profiles of the pile. Results showed that shear displacements and forces are not negligible and suggest that nonlinear shear deformations for RC piles should be considered for fixed-head or similar conditions. Appropriate sensor layout is recommended to capture shear deformation when deriving p-y curves from field measurements.

내부충전 콘크리트와 전단철근을 이용한 중공 PHC말뚝의 전단보강 효과 (Shear Strength Enhancement of Hollow PHC Pile Reinforced with Infilled Concrete and Shear Reinforcement)

  • 현정환;방진욱;이승수;김윤용
    • 콘크리트학회논문집
    • /
    • 제24권1호
    • /
    • pp.71-78
    • /
    • 2012
  • 이 논문에서는 기존 PHC말뚝의 전단성능을 향상시키기 위하여 전단철근과 내부충전 콘크리트로 보강한 ICP 말뚝을 제안하였다. 허용응력 설계법을 바탕으로 전단철근 및 내부충전 콘크리트를 설계하였으며, 이를 바탕으로 2종류의 시험체를 제작하여 KS규격에 따라 전단시험을 수행하였다. 전단시험 결과, KS규격에 의거한 시험방법으로는 전단파괴를 얻을 수 없었으나, 제안된 방법에 의한 전단보강효과는 충분히 검증할 수 있었다. ICP말뚝 시험체의 전단 저항력은 기존 PHC말뚝에 비하여 평균 2배 이상으로 증진되는 것으로 나타났다. 또한 축방향 철근을 추가 보강한 ICP말뚝 시험체의 전단 저항력은 기존 PHC말뚝에 비하여 평균 2.5배 이상 증진되었다. 한편 허용응력설계법에 따라 결정된 ICP 말뚝의 허용 전단력에 비하여 시험으로 측정된 전단강도는 약 2.9 이상의 안전율을 갖는 것으로 나타났다.

Soil slip을 고려한 터널굴착에 의한 단독말뚝의 거동연구 (A Study on the Behaviour of a Single Pile to Tunnelling Including Soil Slip)

  • 이철주
    • 한국지반환경공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.59-67
    • /
    • 2009
  • 본 연구에서는 단독말뚝의 주변에서 실시되는 터널의 굴착이 지반 및 말뚝에 미치는 영향을 3차원 수치해석을 통하여 분석하였다. 수치해석에서는 말뚝과 주변지반 사이에 경계면요소를 이용하여 소성항복 발생조건을 모델링하였다. 수치해석을 통하여 풍화토 및 풍화암에 시공된 터널과 말뚝의 상호거동에 대한 분석을 실시하였다. 수치해석을 통해 말뚝의 침하, 말뚝과 지반 경계면에서의 상대변위, 전단응력 및 말뚝의 축력변화를 분석하였다. 특히 터널의 굴착과 관련된 전단응력의 전이과정에 대한 심도있는 분석을 실시하였다. 터널굴착에 의한 말뚝-지반 경계면에서 상대변위의 변화로 인하여 말뚝에 작용하는 전단응력 및 축력의 분포가 변하게 된다. 말뚝 본체 대부분에서는 상향의 전단응력이 발생하는 반면(Z/L=0.0-0.8), 말뚝선단부근에서는(Z/L=0.8-1.0) 하향의 전단응력이 발생하여 말뚝에 인장력이 발생된다. 수치해석을 통해서 터널굴착이 말뚝 거동에 미치는 영향을 상세하게 분석하였다.

  • PDF

지하터파기로 인해 융기(Heaving)가 발생한 지반에 근입된 단독말뚝의 거동 (Behaviour of a Single Pile in Heaving Ground Due to Ground Excavation)

  • 이철주
    • 한국지반환경공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.27-34
    • /
    • 2010
  • 본 연구에서는 유한요소해석을 실시하여 지반굴착으로 인해 융기(heaving)가 발생하는 지반에 사전에 근입된 말뚝의 거동에 대한 분석을 실시하였다. 수치해석에서는 말뚝과 점토사이 경계면에서의 미끄러짐(소성항복)을 고려하여 그 상호거동에 대하여 고찰하였다. 본 연구에서는 말뚝의 상향변위, 말뚝과 인접지반의 상대변위, 말뚝에 작용하는 전단응력 및 인장력을 분석하였다. 특히, 수직응력의 감소로 인해 말뚝과 인접지반에서의 전단응력이 전이되는 메커니즘에 대한 심도있는 분석을 실시하였다. 굴착에 의해 수직응력이 감소하여 말뚝과 인접지반 사이에서의 상대변위 및 전단응력이 변화하였다. 말뚝 대부분의 위치(Z/L=0.0-0.8)에서는 상향의 전단응력이 발생하였으나, 말뚝 선단부 부근(Z/L=0.8-1.0)에서는 하향의 전단응력이 발생하였고, 이로 인해 말뚝에는 인장력이 발생하였다. Z는 임의의 심도, L은 말뚝의 길이이다. 수치해석을 통해서 분석된 말뚝의 거동에 대하여 상세히 보고하였다.

Effect of raft and pile stiffness on seismic response of soil-piled raft-structure system

  • Saha, Rajib;Dutta, Sekhar C.;Haldar, Sumanta
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.161-189
    • /
    • 2015
  • Soil-pile raft-structure interaction is recognized as a significant phenomenon which influences the seismic behaviour of structures. Soil structure interaction (SSI) has been extensively used to analyze the response of superstructure and piled raft through various modelling and analysis techniques. Major drawback of previous study is that overall interaction among entire soil-pile raft-superstructure system considering highlighting the change in design forces of various components in structure has not been explicitly addressed. A recent study addressed this issue in a broad sense, exhibiting the possibility of increase in pile shear due to SSI. However, in this context, relative stiffness of raft and that of pile with respect to soil and length of pile plays an important role in regulating this effect. In this paper, effect of relative stiffness of piled raft and soil along with other parameters is studied using a simplified model incorporating pile-soil raft and superstructure interaction in very soft, soft and moderately stiff soil. It is observed that pile head shear may significantly increase if the relative stiffness of raft and pile increases and furthermore stiffer pile group has a stronger effect. Outcome of this study may provide insight towards the rational seismic design of piles.

풍화암에서 실시된 터널굴착으로 인한 단독말뚝 및 군말뚝의 거동 (The Response of a Single Pile and Pile Groups to Tunnelling Performed in Weathered Rock)

  • 이철주
    • 대한토목학회논문집
    • /
    • 제32권5C호
    • /
    • pp.199-210
    • /
    • 2012
  • 본 연구에서는 3차원 탄-소성 유한차분해석을 통해 기존재하는 단독말뚝, $3{\times}3$$5{\times}5$ 군말뚝의 바로 아래 풍화암 지반에서 실시된 터널시공으로 인한 말뚝의 거동을 분석하였다. 수치해석에서는 터널굴착으로 인한 말뚝의 거동을 규명하기 위하여 지반/말뚝의 침하 및 전단응력전이(shear stress transfer) 메커니즘을 심도있게 분석하였다. 터널굴착으로 유발된 지반의 침하와 말뚝-지반 사이 경계면에서의 상대변위 발생으로 인해 말뚝에 작용하는 전단응력 및 축력의 분포가 매우 크게 변화하였다. 계산된 결과에 의하면 터널굴착으로 인해 말뚝의 두부로부터 말뚝길이의 약 80%에 해당되는 위치까지는 상향의 전단응력이 발생하였고, 그 하부에서는 하향의 전단응력이 발생하였다. 이로 인해 말뚝의 축력이 터널의 굴착에 따라 지속적으로 감소하고, 순수한 터널의 시공으로 인하여 말뚝에는 인장력이 발생하였는데 이로 인해 말뚝에는 최대 $0.36P_a$의 인장력이 발생하였다, 여기서 $P_a$는 터널굴착이전에 말뚝두부에 작용하는 설계하중이다. 말뚝의 거동은 경계면에서의 전단강도 발현 정도에 가장 큰 영향을 받는 것으로 나타났다. 군말뚝의 경우 일반적으로 말뚝의 숫자가 증가할수록 터널의 시공에 의해 말뚝의 침하가 증가하는 것으로 나타났으며, 이와는 반대로 말뚝의 축력변화는 군효과(shielding effect)로 인해 단독말뚝의 경우에 비해 작은 것으로 분석되었다. 터널굴착으로 인한 말뚝침하의 증가로 인한 겉보기지지력(apparent pile capacity) 감소는 단독말뚝에 비해 군말뚝에서 두드러지는 것으로 분석되었다.

단독말뚝의 측면으로 시공되는 터널에 의한 말뚝의 거동 연구 (A Study on the Behaviour of a Single Pile to Adjacent Tunnelling Conducted in the Lateral Direction of the Pile)

  • 이철주
    • 한국지반환경공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.41-50
    • /
    • 2011
  • 본 연구에서는 단독말뚝의 측면에서 시공되는 터널에 의한 말뚝의 거동에 대하여 3차원 수치해석을 통하여 분석하였다. 수치해석을 통하여 터널-말뚝-지반의 상호거동에 대한 심도 있는 분석을 실시하였다. 수치해석을 통해 말뚝의 침하, 말뚝과 주변지반 사이의 상대변위, 전단응력 및 말뚝의 축력변화를 고찰하였다. 특히 터널굴착에 의한 전단응력의 전이과정에 대한 심도 있는 분석을 실시하였다. 터널굴착에 의한 말뚝과 인근지반에서의 상대변위 변화로 인하여 말뚝에 작용하는 전단응력 및 축력의 분포가 변하게 되는 것으로 나타났다. 터널 중심부의 상부에서는 하향의 전단응력이 발생하는 반면(Z/L=0.0-0.7~0.8), 그 하부에서는 (Z/L=0.7~0.8-1.0) 상향의 전단응력이 발생하여 말뚝에 압축력이 발생된다, 이때 Z는 임의의 심도, L은 말뚝의 길이다. 터널굴착이 종료된 후 말뚝에는 최대 $0.475P_a$의 압축력이 발생하였다, 이때 $P_a$는 말뚝의 설계지지력이다. 수치해석을 통해서 도출된 터널굴착이 말뚝 거동에 미치는 영향에 대해 상세히 고찰하였다.

사용 중인 단독 및 군말뚝의 측면에서 실시된 터널굴착으로 인한 말뚝의 거동 (Behaviour of single piles and pile groups in service to adjacent tunnelling conducted in the lateral direction of the piles)

  • 이철주
    • 한국터널지하공간학회 논문집
    • /
    • 제14권4호
    • /
    • pp.337-356
    • /
    • 2012
  • 본 연구에서는 3차원 유한요소해석을 실시하여 사용 중인 단독말뚝 및 군말뚝의 측면에서 실시된 터널굴착에 의한 말뚝의 거동을 분석하였다. 수치해석에서는 터널굴착으로 유발된 말뚝-지반 경계면에서의 전단응력전이를 미끄러짐(slip)을 고려할 수 있는 접촉요소(interface element)를 이용하여 분석하였다. 본 연구는 말뚝-지반경계면에서의 전단응력, 말뚝의 축력 및 지반 및 말뚝의 변형에 대한 분석을 포함한다. 탄성이론에 근거한 기존의 연구는 말뚝의 거동에 영향을 미치는 주요인자들을 적절히 고려하지 못하여 말뚝의 거동을 명확하게 분석할 수 없는 것으로 나타났다. 터널굴착으로 유발된 말뚝-지반 사이에서의 전단응력전이로 인하여 말뚝인접 지반의 전단응력 및 말뚝의 축력분포가 크게 변하는 것으로 나타났는데, 터널 springline 상부에서는 하향의 마찰력이 발생하였으며, 그 하부에서는 상향의 저항력이 발현되어 말뚝에는 압축력이 발생하였다. 경계면에서의 전단응력 발현정도는 말뚝-지반의 상호거동에 가장 큰 영향을 미치는 것으로 분석되었다. 군말뚝의 축력분포에 대한 분석결과 단독말뚝에 비해 터널굴착의 영향을 덜 받는 것으로 나타났다. 터널굴착으로 유발된 말뚝의 침하와 관련된 말뚝의 겉보기 지지력 감소는 크지 않은 것으로 분석되었다.

Cyclic behavior of connection between footing and concrete-infilled composite PHC pile

  • Bang, Jin-Wook;Hyun, Jung Hwan;Lee, Bang Yeon;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.741-754
    • /
    • 2014
  • The conventional PHC pile-footing connection is the weak part because the surface area and stiffness are sharply changed. The Composite PHC pile reinforced with the transverse shear reinforcing bars and infilled-concrete, hereafter ICP pile, has been developed for improving the flexural and shear performance. This paper investigates the cyclic behavior and performance of the ICP pile-footing connection. To investigate the behavior of the connection, one PHC and two ICP specimens were manufactured and then a series of cyclic loading tests were performed. From the test results, it was found that the ICP pile-footing connection exhibited higher cyclic behavior and connection performance compared to the conventional PHC pile-footing connection in terms of ductility ratio, stiffness degradation and energy dissipation capacity.