• Title/Summary/Keyword: pile design

Search Result 810, Processing Time 0.027 seconds

Static impedance functions for monopiles supporting offshore wind turbines in nonhomogeneous soils-emphasis on soil/monopile interface characteristics

  • Abed, Younes;Bouzid, Djillali Amar;Bhattacharya, Subhamoy;Aissa, Mohammed H.
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1143-1179
    • /
    • 2016
  • Offshore wind turbines are considered as a fundamental part to develop substantial, alternative energy sources. In this highly flexible structures, monopiles are usually used as support foundations. Since the monopiles are large diameter (3.5 to 7 m) deep foundations, they result in extremely stiff short monopiles where the slenderness (length to diameter) may range between 5 and 10. Consequently, their elastic deformation patterns under lateral loading differ from those of small diameter monopiles usually employed for supporting structures in offshore oil and gas industry. For this reason, design recommendations (API and DNV) are not appropriate for designing foundations for offshore wind turbine structures as they have been established on the basis of full-scale load tests on long, slender and flexible piles. Furthermore, as these facilities are very sensitive to rotations and dynamic changes in the soil-pile system, the accurate prediction of monopile head displacement and rotation constitutes a design criterion of paramount importance. In this paper, the Fourier Series Aided Finite Element Method (FSAFEM) is employed for the determination of static impedance functions of monopiles for OWT subjected to horizontal force and/or to an overturning moment, where a non-homogeneous soil profile has been considered. On the basis of an extensive parametric study, and in order to address the problem of head stiffness of short monopiles, approximate analytical formulae are obtained for lateral stiffness $K_L$, rotational stiffness $K_R$ and cross coupling stiffness $K_{LR}$ for both rough and smooth interfaces. Theses expressions which depend only on the values of the monopile slenderness $L/D_p$ rather than the relative soil/monopile rigidity $E_p/E_s$ usually found in the offshore platforms designing codes (DNV code for example) have been incorporated in the expressions of the OWT natural frequency of four wind farm sites. Excellent agreement has been found between the computed and the measured natural frequencies.

A Study on Korean Man's Head Ornaments in the Joseon Dynasty (조선시대 남자(男子)의 수식(首飾) 연구(I))

  • Chang, Sook-Whan
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.10 no.1
    • /
    • pp.99-116
    • /
    • 2008
  • This study reviewed pertinent literature and examined relics of manggon(a headband worn to hold a man's topknot hair in place), donggot(a topknot pin), and chigwan(a topknot cover). Before the modernized short hair style, wearing a gat was an important custom. Therefore, manggon, which was used to hold a man's hair in place under the gat, was considered an essential part of the man's official dress code. Donggot is a pin that held the topknot hair in place. It was a must have for a married man, like the binyeo, a lod-like hairpin, for a married woman. Unlike gwanja, it had nothing to do with official rank, but materials were of a variety of materials, including jade and gold. The structure of the donggot was studied in three parts-head, neck and body. Major forms for the head include the mushroom, bean and ball. Bullet and half-cut bullet forms were also found. Forms for the neck include straight-neck and curved-neck. A neck with a belt around a double chin was also found. Forms for the body include the tetrahedron, octahedron and cylinder. The most popular form for silver and white bronze donggot heads was the mushroom, followed by bean and pile forms. Chigwan is also called chipogwan, chichoal, choalgyesogwan, noingwan and sangtugwan. In poetry it was called chichoal, and it used to be called taegogwan in the past as well. Chigwan was so small that it managed to hold a topknot. According to confucian custom in the Joseon period, by wearing chigwan, men didn't display their bare topknot even when they didn't dress up. When they went out, they wore another official hat over the chigwan.

  • PDF

Economic Evaluation on Geosynthetic Reinforced Abutment for Railways (특정형상의 인공자갈이 혼합된 도상자갈층의 지지성능과 응력전달특성)

  • Kim, Dae Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.15-20
    • /
    • 2019
  • This paper evaluated the construction costs of 11 design cases to decrease the horizontal forces applied to the abutment. They include two abutment types, which are to improve backfill materials for a reversed T-shaped abutment and geosynthetic Reinforced Abutment for Railways (RAR). The first type of economic analysis was that the internal friction angles of backfill materials were increased from Φ=35° to Φ=40° and 50° for a reversed T-shaped abutment. In addition, the second type was the cases with the design of geosynthetic RAR. When friction angles of 40° or 50° were applied through the improvement of the backfill material, the decrease in construction cost of the abutment was not large (2.0~3.9%), even though the horizontal forces applied to the abutment had decreased to 18~48%. In the case of applying the RAR, however, a maximum 30% cost reduction was evaluated by the decrease in horizontal force to "0" theoretically. The cost reduction resulted from the decrease in wall thickness, base slab size, and number and material change of pile foundation for the abutment.

A Study on the Safety Test Regulation for the Metallic Sound Barrier of the Absorption Type (금속재 흡음형 방음벽의 안전 시험 규정 분석 연구)

  • Huh, Young
    • Explosives and Blasting
    • /
    • v.20 no.4
    • /
    • pp.5-15
    • /
    • 2002
  • For the noise reduction measures in a construction field where noise sources such as blasting and pile driving works exist, the construction of the sound barrier near the noise source or receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusion were reached that it is required to improve test methods in KS F4770-1 as well as to break down loads for building more cost-effective sound barrier. In addition, KS F4770-1 was compared with ZTV-Lsw 88 which is the german regulation for sound barrier design. As a result, it was found that the Korean regulation is more conservative than that of Germany.

Soil and ribbed concrete slab interface modeling using large shear box and 3D FEM

  • Qian, Jian-Gu;Gao, Qian;Xue, Jian-feng;Chen, Hong-Wei;Huang, Mao-Song
    • Geomechanics and Engineering
    • /
    • v.12 no.2
    • /
    • pp.295-312
    • /
    • 2017
  • Cast in situ and grouted concrete helical piles with 150-200 mm diameter half cylindrical ribs have become an economical and effective choice in Shanghai, China for uplift piles in deep soft soils. Though this type of pile has been successful used in practice, the reinforcing mechanism and the contribution of the ribs to the total resistance is not clear, and there is no clear guideline for the design of such piles. To study the inclusion of ribs to the contribution of shear resistance, the shear behaviour between silty sand and concrete slabs with parallel ribs at different spacing and angles were tested in a large direct shear box ($600mm{\times}400mm{\times}200mm$). The front panels of the shear box are detachable to observe the soil deformation after the test. The tests were modelled with three-dimensional finite element method in ABAQUS. It was found that, passive zones can be developed ahead of the ribs to form undulated failure surfaces. The shear resistance and failure mode are affected by the ratio of rib spacing to rib diameter. Based on the shape and continuity of the failure zones at the interface, the failure modes at the interface can be classified as "punching", "local" or "general" shear failure respectively. With the inclusion of the ribs, the pull out resistance can increase up to 17%. The optimum rib spacing to rib diameter ratio was found to be around 7 based on the observed experimental results and the numerical modelling.

A Study on the Behavior of Sand Compaction Piles in Soft Ground (연약지반에 적용된 모래다짐말뚝의 거동특성에 관한 수치해석 연구)

  • Lee, Jungsang;Chung, sungrae;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.8
    • /
    • pp.33-38
    • /
    • 2011
  • Presently, domestic SCP method with low replacement ratio is required as alternative in order to overcome the profitability of the sand resource because of the deficiency phenomenon of the sand resource by the actual condition design and construction is made by SCP method with low replacement ratio more than 70% for the port construction in the safe side. Sand compaction pile(SCP) method has been mainly used to improve the properties of soft clay or loose sandy ground. In design of SCP at soft clay ground, it is very important to determine the stress concentration ratio of composite ground relevant to the area replacement ratio. In this study, 2-dimensional FEM analyses were carried out to evaluate the stress concentration ratio of composite ground depending upon the area replacement ratio. When the interpretation result replacement ratio was 30%, the stress assigned rate showed and as the replacement ratio was high, the stress assigned rate according to the sinkage showed the low stress assigned rate.

An Analysis on Co-relationships Between In-situ Investigation Methods and End Bearing Capacity of A Drilled Shaft Socketed into the Weathered Zone (풍화대소켓 현장타설말뚝의 극한단위선단지지력과 원위치 지반조사방법들과의 상관관계 분석)

  • Choi, Yongkyu;Kwon, Oh Sung;Lee, Jong Seong;Choi, Sung Soon;Jung, Sung Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.95-107
    • /
    • 2010
  • To calculate the end bearing capacity of a drilled Shaft socketed into the rockmass, the unconfined compression strength could be used. But it is difficult to find the unconfined compression strength because it is impossible to get undisturbed samples in weathered soils and rocks. So, to calculate the end bearing capacity, the existing bearing formula could not be used. In this study, for five zones (near pile tip, tip~lower 1D, tip~lower 2D, upper 1D~lower 1D, upper 1D~lower 2D), the relationships between the characteristic values of in-situ tests(SPT, DCPT PMT, BST) and the end bearing capacity of drilled shafts were analysed. As a result, DCPT results were represented the best credibility. Also, a design chart of end bearing capacity using DCPT was suggested.

Analysis on the Analytical Behavior of Soft Ground Reinforced with Granular Compaction Piles (GCP로 보강된 연약지반의 해석적 거동분석)

  • Kim, Min-Seok;Na, Seung-Ju;Yang, Yeol-Ho;Kim, Daehyeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.3
    • /
    • pp.27-37
    • /
    • 2016
  • Although many studies on the Granular Compaction Pile (GCP) have been done by many researchers, the GCP design has not been systematically done due to the absence of the rational design methodology. As the GCP design has been mostly done by engineers' own experiences, some failure cases have been reported to occur. For this reason, it is very difficult to confirm definite causes of the failure and establish the prevention plans for the failure. Therefore, this study aims to investigate the optimal mixing ratio of gravel and sand, the effects of the internal friction angle of the GCP on the stress concentration ratio and the vertical and horizontal settlements. In order to analyze the behavior of the soft ground reinforced with the GCP depending on the different design parameters such as the stress concentration ratio and the internal friction angle, a number of finite element (FE) analyses were performed. From the direct shear test, the optimal mixing ratio of gravel to sand was found to be 70:30. Based on the numerical analyses, as the internal friction angle increased, the stress concentration ratio increased and it converged to a constant value. In addition, the larger the internal friction angle, the smaller the settlements. Consequently, the use of the optimal mixing ratio of gravel and sand can lead to reducing both the lateral flow and the heaving phenomenon.

A Design Principles and Characteristics of the Garden of Salt Merchant in Yangzhou, China's Ming and Qing Dynasties (중국 명·청 양주 염상원림의 설계원리 및 조영특성)

  • Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.83-92
    • /
    • 2019
  • This study aims to examine at the garden characteristics of salt merchant in Yangzhou, China during the Ming and Qing Dynasties, I looked at the background of garden formation through the literature. In addition, analyzed the garden design method and components of salt merchants. The results were as follows; First, the Yangzhou area in the past has achieved cultural and economic development with the establishment of the ancient Grand Canal. Salt merchants accumulated wealth through trade, and created many gardens under the background of securing materials for create garden through trade, forming political forces through the cultivation of students, and inflow of foreign cultures. Second, salt merchants in Yangzhou asked garden experts to design and create the garden as a place for exchange and relaxation. Also, through the production of landscape changes using Gasan(假山) and a long corridor(長廊), clear classification of spaces using architectural elements, and the placement of buildings in scenic areas adjacent to the water, the gardens with practical and aesthetic functions were owned. Third, the gardens of Yangzhou Salt Merchants have a building-oriented commercial space on the front, and a garden-centered design characteristic on the back. The garden of the commercial zone was built in a simple form using pots, oddly shaped stone, bamboo and fence patterns in the remained space, focusing on the front of the building. The garden at the back formed a curved waterway connected to the canal is refracted across the garden. The garden also features piled stones(疊石), stone bridges and ship-shaped stone building(石舫). In addition, the design reflected the introduction of trees that take into account the climate and color contrast of Yangzhou province, pavement of various materials and patterns.

Determination of Resistance Factors of Load and Resistance Factor Design for Drilled Shaft Based on Load Test (LRFD 설계를 위한 현장타설말뚝의 주면지지력 저항계수 산정)

  • Kim, Seok-Jung;Kwon, Oh-Sung;Jung, Sung-Jun;Han, Jin-Tae;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.17-24
    • /
    • 2010
  • Load Resistance Factor Design method is used increasingly in geotechnical design world widely and resistance factors for drilled shafts are suggested by AASHTO. However, these resistance factors are determined for intact rock conditions; by comparison, most of bedrocks in Korea have weathered condition, so that applying the AASHTO resistance factors is not reasonable. Thus, this study suggests the proper resistance factors for design of drilled shaft in Korea. The 22 cases of pile load test data from 8 sites were chosen and reliability-based approach is used to analyze the data. Reliability analysis was performed by First Order Second Moment Method (FOSM) applying 4 bearing capacity equations. As a result, when the Factor of Safety (FOS) was selected as 3.0, the target reliability indexes (${\beta}_c$) were evaluated as 2.01~2.30. Resistance factors and load factors are determined from optimization based on above results. The resistance factors ranged between 0.48 and 0.56 and load factors for dead load and live load are evaluated as approximately 1.25 and 1.75 respectively. However, when the target reliabilities are considered as 3.0, the resistance factors are evaluated as approximately 50% of the results when the target reliability index was 2.0.