• 제목/요약/키워드: piezo

검색결과 710건 처리시간 0.027초

인젝터 구동 방식에 따른 분무 거동 및 분무 미립화 특성 (Effect of Injector-driven Type on Spray Behavior and Fuel Atomization Characteristics)

  • 박지홍;서현규;박성욱;김재욱;이창식
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.17-24
    • /
    • 2006
  • This study was performed to figure out spray behavior and fuel atomization characteristics of a piezo-driven injector and a solenoid-driven injector in the common-rail injection system under the same design parameters and test conditions. The process of spray injection was visualized by using the spray visualization system composed of a Nd:YAG laser and an ICCD camera. The atomization characteristics were investigated in terms of axial mean velocity, Sauter mean diameter(SMD) and droplet distributions obtained from a phase Doppler particle analyzer system. Compared with solenoid-driven injector, the piezo-driven injector has short injection delay and reaches quickly to the maximum injection value. Spray tip penetration shows some difference, however, spray angle of piezo-driven injector is wider than that of solenoid-driven injector. Sauter mean diameter of piezo-driven type injector is smaller than that of solenoid-driven type.

피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구 (A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer)

  • 권승열;이동훈;최재욱
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

Eulerian-Lagrangian 다상 유동해석법에 의한 피에조 인젝터의 노즐 내부 비정상 캐비테이션 유동해석 (Analysis of Unsteady Cavitating Flows in Fuel Injection Nozzle of Piezo-driven Injector by Eulerian-Lagrangian Multi-phase Method)

  • 이진욱;민경덕;강건용
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.38-45
    • /
    • 2004
  • This study describes the analysis results of unsteady cavitating flows behavior inside nozzle of the prototype piezo-driven injector. This piezo-driven injector has been recognised as one of the next generation diesel injector due to a higher driven efficiency than the conventional solenoid-driven injector. The three dimensional geometry model along the central cross-section regarding of one injection hole has been used to simulate the cavitating flows for injection time by at fully transient simulation with cavitation model. The cavitation model incorporates many of the fundamental physical processes assumed to take place in cavitating flows. The simulations performed were both fully transient and 'pseudo' steady state, even if under steady state boundary conditions. We could analyze the effect the pressure drop to the sudden acceleration of fuel, which is due to the fastest response of needle, on the degree of cavitation existed in piezo-driven injector nozzle

  • PDF

충격하중을 받는 보에서 압전 필름센서와 웨이브렛 변환을 이용한 문산파동의 해석 (Dispersive Wave Analysis of a Beam under Impact Load by Piezo-Electric Film Sensor and Wavelet Transform)

  • 권일범;최만용;정현조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.215-225
    • /
    • 2001
  • Stress waves monitored on the surface of structures under various loading conditions can provide useful information on the structural health status. In this paper, stress waves are measured by several sensors when a steel beam is impacted by a ball drop. The sensors used include the piezo-electric film Sensor, the electrical strain gage, and the ultrasonic transducer, and special attention is given to the pieza film sensor. The wavelet transform is used for the time-frequency analysis of dispersive waves propagating in the beam. The velocities of the wave produced in the team due to the lateral impact is found to be frequency-dependent and identified as the flexural wave velocity based on the comparisons with the Timoshenko beam theory. A linear impact site identification method is developed using the flexural wave, and the impact sites of the beam can be accurately estimated by the piezo film sensors. It is found that the piezo film sensor is appropriate for sensing stress waves due to impact and for locating impact sites in the beam.

  • PDF

The effect of rotation on piezo-thermoelastic medium using different theories

  • Othman, Mohamed I.A.;Ahmed, Ethar A.A.
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.649-665
    • /
    • 2015
  • The present paper attempts to investigate the propagation of plane waves in generalized piezo-thermoelastic medium under the effect of rotation. The normal mode analysis is used to obtain the expressions for the displacement components, the temperature, the stress and the strain components. Comparisons are made with the results predicted by different theories (Coupled theory, Lord-Schulman, Green-Lindsay) in the absence and presence of rotation.

경량 압전 작동기(LIPCA)의 작동성능 평가를 위한 유한요소 해석 (Finite Element Analysis for Performance Evaluation of Lightweight Piezo-composite Curved Acutator)

  • 구남서;박훈철;윤광준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2000
  • A numerical method fur performance evaluation of LIPCA is proposed using a finite element method. Fully coupled formulations for piezo-electric material are introduced and eight-node incompatible element is used. After verifying the developed code, the behaviors of LIPCA and $THUNDER^{TM}$ are investigated.

  • PDF

잉크젯을 이용한 TFT LCD 컬러필터 제작에 있어 잉크액적 부피 편차에 대한 이론적 해석 (Theoretical analysis of one possible cause of the droplet volume variation for the fabrication of a TFT LCD color filter with the piezo DOD inkjet printing technology)

  • 신동윤;이택민;김충환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2563-2566
    • /
    • 2007
  • TFT LCD industries have endeavored to adopt the piezo Drop-On-Demand (DOD) inkjet printing technology to production lines of TFT LCD color filters and these efforts have significantly been based on experimental works. Because the degree of complexity in the piezo DOD inkjet printing technology results in too many combination of parameters, the matrix experimental method to investigate all possible sets of parameters becomes ineffective and hence the basic understanding of the piezo Drop-On-Demand inkjet print technology becomes important. In this study, one possible cause of the droplet volume variation across nozzles, which might cause visible swathe marks on an inkjet patterned TFT LCD color filter, is theoretically investiaged and new R&D directions are suggested.

  • PDF

기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구 (Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제28권4호
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

Multi-Piezo 헤드를 이용한 3차원 프린팅 기법 (3DP Printing Method using Multi-Piezo Head)

  • 김정수;김동수;이민철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1394-1399
    • /
    • 2007
  • Recently, Study of 3D freeform fabrication method was working in the various applications. For example, in the powder base, it's laminated using a binding method or laser sintering method. However, these methods are not suitable in the office environments because it dust with powder that is bad for health. In this paper, we introduce a method of 3D freeform fabrication using a curing of photo-polymer resin and construct a system has multi printing head. A photo-polymer curing method has simply fabrication process and high strength of manufacturing part. However, this method has a problem on the multi print-head system. Because multi-printing system has a other printing method compare with a single printing system. Therefore, we experiment a single head 3D printing and proposed a 3D printing method using a multi-piezo head.

  • PDF

이중서보제어루프를 통한 서보모터-압전구동기의 초정밀위치결정 시스템 (Ultra precision positioning system for Servo Motor-Piezo actualtor using dual servo loop)

  • 이동성;박종호;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.437-441
    • /
    • 1995
  • In this paper, the ultra precision positioning system for servo motor and piezo actuator using dual servo loop control has been developed. For positioning system having long distance with ultra precision, the combination of global stage and micro stage is required. Servo moter and ball screw are used as a master stage and piezo acuator as a fine stage. By using this system, an positional precision witin .+-. 30nm has been achieved at dual servo loop control. When using micro stage, an positional precision within .+-. 10nm has been achieved. This result can be applied to develop semiconductor equipment such as wafer stepper.

  • PDF