• Title/Summary/Keyword: physical simulation test

Search Result 243, Processing Time 0.032 seconds

A study on the flow characteristics around a suction pipe of circulation water pump in thermal power plant (화력발전소 순환수펌프 흡입관 주위에서의 유동특성에 관한 연구)

  • Choi, Sung-Tyong;Ahn, Jung-Hyeon;Moon, Seung-Jae;Lee, Jae-Heon;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.201-204
    • /
    • 2008
  • Vortex and swirl occurring in a pump suction intake sump normally reduce the performance and disturb the safe operation of the circulation water pump in thermal power plants. This paper presents a case study of one particular intake sump design via a CFD analysis and a hydraulic model testing. The physical experiments and numerical analysis were performed under two flow and three level variation conditions. The vortex patterns around the pump suction pipe have been predicted by a commercial CFD code with the k-${\varepsilon}$ model. The model tests were conducted on a 1/10 model for a practical intake sump. The location, number and general pattern of the free surface vortex and submerged vortex predicted by CFD simulation were found to be a good agreement with those observed in the model testing.

  • PDF

Design and Assessments of a Closed-loop Hydraulic Energy-Regenerative System (폐루프 유압 에너지 회생 시스템에 관한 연구)

  • Hung, H.T.;Yoon, J.I.;Ahn, K.K.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.116-125
    • /
    • 2010
  • In this study, a novel hydraulic energy-regenerative system was presented from its proposal through its modeling to its control. The system was based on a closed-loop hydrostatic transmission and used a hydraulic accumulator as the energy storage system in a novel configuration to recover the kinetic energy without any reversion of the fluid flow. The displacement variation in the secondary unit was reduced, which widened the uses of several types of hydraulic pump/motors for the secondary unit. The proposed system was modeled based on its physical attributes. Simulation and experiments were performed to evaluate the validity of the employed mathematical model and the energy recovery potential of the system. The experimental results indicated that the round trip recovery efficiency varied from 22% to 59% for the test bench.

  • PDF

A Study on the Torque Control Method of a Hydraulic Actuation System for Measuring the Dynamic Stiffness of Missile Fin Actuators (유도무기용 날개구동기의 동적 강성 측정을 위한 유압 구동장치의 토크제어 기법에 관한 연구)

  • Lee, Ho-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • This paper presents a torque control method of a hydraulic actuation system for measuring the dynamic stiffness of missile fin actuators. We propose a new control technique called Dual Dynamic Torque Feedback Control(DDTFC), which improves the stability of the torque control system and enables fast tracking of torque command. The developed control scheme is derived from the physical understanding based on mathematical modelling and analysis. The dynamics of hydraulic torque control servo-system is unravelled via physics-based modelling and nonparametric system identification. In order to verify the effectiveness of the method, the experiment is carried out with a test equipment for measuring the dynamic stiffness. The experiment and simulation results show that DDTFC gives stability improvement.

Design and Fabrication of Scaffold Type Energy Harvester Using Multiplying Gear Module (증속기어 모듈을 이용한 발판형 에너지 하베스터의 설계 및 제작)

  • Min, Chul Hong;Kim, Tae Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.12
    • /
    • pp.857-862
    • /
    • 2014
  • In this paper, we designed and fabricated electromagnetic induction based scaffold type energy harvester. For energy harvesting, mechanical energy of vertical motion is transferred to rotational energy using rack gear and multiplying gear was used to maximize energy transfer. To optimize design parameters, physical structure of energy harvester was modeled using finite element method. The effect of multiplying gear ratio and frequency levels of applied mechanical energy on energy generation efficiency are analyzed by computer simulation and experimental test. Experimental results showed that maximum 25.36 W of electric power can be achieved at the frequency of 2 Hz and 1:77 of gear ratio with only 5 mm of vertical changes on scaffold structure.

Computationally Efficient and Accurate Simulation of Cyclic Behavior for Rectangular HSS Braces

  • Lee, Chang Seok;Sung, Min Soo;Han, Sang Whan;Jee, Hyun Woo
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1125-1138
    • /
    • 2018
  • During earthquakes, braces behave in complex manners because of the asymmetric response nature of their responses in tension and compression. Hollow structural sections (HSS) have been popularly used for braces due to their sectional efficiency in compression. The purpose of this study is to accurately simulate the cyclic behavior of rectangular HSS braces using a computationally efficient numerical model. A conceptually efficient and simple physical theory model is used as a basis model. To improve the accuracy of the model, cyclic beam growth and buckling load, as well as the incidences of local buckling and brace fracture are estimated using empirical equations obtained from regression analyses using test data on rectangular HSS braces. The accuracy of the proposed model is verified by comparing actual and simulated cyclic curves of brace specimens with various slenderness and width-to-thickness ratios.

Development of OPC UA based Smart Factory Digital Twin Testbed System (OPC UA 기반 스마트팩토리 디지털 트윈 테스트베드 시스템 개발)

  • Kim, Jaesung;Jeong, Seok Chan;Seo, Dongwoo;Kim, Daegi
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1085-1096
    • /
    • 2022
  • The manufacturing industry is continuously pursuing advanced technology and smartization as it converges with innovative technology. Improvement of manufacturing productivity is achieved by monitoring, analyzing, and controlling the facilities and processes of the manufacturing site in real time through a network. In this paper, we proposed a new OPC-UA based digital twin model for smart factory facilities. A testbed system for USB flash drive packaging facility was implemented based on the proposed digital twin model and OPC-UA data communication scheme. Through OPC-UA based digital twin model, equipment and process status information is transmitted and received from PLC to monitoring and control 3D digital models and physical models in real time. The usefulness of the developed digital twin testbed system was evaluated through usability test.

PREVENTION STRATEGIES TO CONTROL AN EPIDEMIC USING A SEIQHRV MODEL

  • Mohit Soni;Rajesh Kumar Sharma;Shivram Sharma
    • The Pure and Applied Mathematics
    • /
    • v.31 no.2
    • /
    • pp.131-158
    • /
    • 2024
  • This study investigates the impact of precautionary measures, such as isolating exposed individuals, wearing masks, and maintaining physical distance, on preventing infectious disease. A deterministic SEIQHRV epidemic model is employed for this purpose. The model's positivity, boundedness, disease-free, and endemic equilibrium points are identified. A sensitivity test assesses the impact of preventive measures on infected classes. Results show that a basic reproduction number less than unity drives disease eradiction, while a higher unity value encourages the adoption of preventive measures.

Validity and Reliability of a Clinical Performance Examination using Standardized Patients (호흡기계 표준화 환자를 이용한 간호대 학생의 임상수행능력평가 타당도와 신뢰도 검증)

  • Choi, Ja-Yun;Jang, Keum-Seong;Choi, Soon-Hee;Hong, Mi-Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • Purpose: The purpose of this study was to test the validity of a modified clinical performance examination (CPX) for preclinical students in nursing. Method: 70 nursing students in their second semester of the junior year at C University participated in CPX. Scenarios and checklists were developed by our research team from September to October 2005. Six stations were organized. Evaluation included physical examination of a patient with lung cancer, education on usage of a metered dosage inhaler, and lobectomy postoperative care. Students were randomly assigned to a station. Result: There was a difference in the CPX scores according to stations. The agreement of scoring between trained faculty members and SPs was more than moderate (r=.647). The correlation between the CPX score and the average grade in the previous semester and between the CPX score and the average grade of a paper and pen test of the pulmonary system of adults was low (r=.276; r=.048). Conclusion: Traditional CPX is generally recommended, however, modified CPX is appropriate for preclinical students in the current Korean Nursing school setting if there are additional scoring systems to balance the testing level at each station.

Consideration of the Frictional Force on the Crack Surface and Its Implications for Durability of Tires

  • Park, K.S.;Kim, T.W.;Jeong, H.Y.;Kim, S.N.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2159-2167
    • /
    • 2006
  • In order to find out a physical quantity which controls the fatigue life of a structure and to predict the fatigue life of tires, a finite element simulation methodology to use the cracking energy density (CED) and the virtual crack closure technique (VCCT) was proposed and applied to three different tires of a similar size. CED was calculated to predict the location of a crack initiation, and VCCT was used to obtain the strain energy release rate (SERR) at the tip of an initiated crack. Finite element simulations showed that SERR oscillated in the circumferential direction with its minimum occurring just before the contact zone and its maximum occurring just after the center of the contact zone, and SERR was affected significantly by the frictional force acting on the crack surface. In addition, a durability test was conducted to measure the fatigue life of the three tires. The comparison of SERR values with the test data revealed that the fatigue life increased as the amplitude of SERR decreased or as the R-ratio of SERR increased.

Thermal Structural Analysis of the Engine Turbocharger under the Transient Temperature History Corresponding to the Motoring Fatigue Test (모터링 내구시험을 상사한 비정상 온도이력을 받고 있는 엔진 터보차져의 열적 거동해석)

  • Choi, Bok-Lok;Bang, In-Wan;Chang, Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.126-132
    • /
    • 2011
  • Fatigue cracks of the turbocharger are often observed for high performance engines under thermal shock tests. Maximum exhaust gas temperature of recently developed gasoline engines could reach approximately $950^{\circ}C$. It's very important to estimate transient temperature histories during thermal shock cycles to predict the stress and the fatigue life of the turbocharger. With these temperature profiles, temperature-dependent material properties and boundary conditions, we could identify critical locations by the application of finite element simulation technologies. In this paper, we applied the reliable analysis approach to the actual turbocharger to predict the weak locations due to the repetitions of plastic strains and compared the results with the crack locations under physical engine test.