• Title/Summary/Keyword: physical simulation test

Search Result 244, Processing Time 0.024 seconds

Application of SDAHL-74 Watershed Model to a Long Term Runoff Analysis in the Mountainous Watershed (산지유역에 대한 USDAHL-74 유역수문모형의 장기유출 해석적용)

  • 권순국;고덕구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.2
    • /
    • pp.53-63
    • /
    • 1987
  • Due to their wide range of application, deterministic comprehensive hydrologic models using digital computers have been developed in all countries of the world and researches are being undertaken for their appropriate applications. The aim of this study has been to demonstrate the practical implementation of a physically based distributed hydrologic model, the USDAHL-74 model and to investigate its ability to simulate the long term estimate of water balance quantities in a Korean mountainous watershed. Application of the model to Dochuk watershed indicates the following results. 1.Since the USDAHL-74 model includes all the major components of the hydrologic cycle in agricultural watersheds, thus is comprehnsive, the model seems to have a wide range of application from the fact that simulation results obtained are not only runoff volumes m various time units but their spatial variation as well as even soil moisture within the watershed. 2.An approximate calibration to determine the parameter values in the model using various data obtained from D0chuk shed shows that the simulation error of yearly runoff volume is only 0.6 % and a correlation coefficient between observed daily runoff volume and simulated one is 0.91 in all calibrated period.3.As a verification test of the model, runoff volumes are simulated using 1986 year data without changing the parameter values determined by 1985 year data. The tests show that the USDAHL-74 model is a flexible tool and that realistic production to simulate the long term estimate of runoff in Korean mountainous watershed could be obtained using only a short period of calibration.4. Despite of the encouraging results, there still remain minor problems concerning the practical application of the model to improve the result of simulations. Some of these are the small descrepancies between observed and simulated daily runoff volume appeared in the vicinity of peaks and the recession of1 the daily hydrographs and the model performance for the frozen ground and melting process in the model. 5. Alough the use of parameter with physical significance and the ability to improve calibrations on the basis of physical reasoning represents advantages in the simulation for ungaged watersheds, further researches are needed to use the USDAHL-74 mode to simulate runoff in ungaged watersheds.

  • PDF

Development of an Online Evaluation Model for Traffic Signal Control System (교통신호제어시스템 온라인 평가모형 개발)

  • Go, Gwang-Yong;Lee, Seung-Hwan
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.3
    • /
    • pp.31-40
    • /
    • 2008
  • There have been a lot of efforts to find more accurate evaluation methods for traffic signal control effectiveness for a long period of time. Nowadays a newly advanced method called HILSS, 'Hardware-in-the-Loop-Simulation System', is used to evaluate the overall traffic control's effectiveness including physical control environments like communication conditions, hardware performance, controller's mechanical operations and so on. In this study, an Online-HILSS model has been developed, which runs on CORSIM(5.0) micro traffic simulation model on-lined to COSMOS. For the verification of the model, three tests are performed as follows; (1) a comparison of TMC's timing plan with the simulated green interval, (2) as a case study, a delay distribution comparison of the online simulation with the CORSIM stand-alone simulation. The result of the first test shows that the model can run the simulation green interval by TMC's timing plan correctly. The result of second test shows that the online simulation of the model brings the same simulation results with the CORSIM offline simulation in case of the same timing plan. These results mean that the online evaluation model could be a reliable tool to measure a real-time signal control effectiveness of a wide area street network with the HILSS method.

Implicit Time Integration Scheme for Real-Time Hybrid Test System (실시간 하이브리드 실험 시스템을 위한 Implicit 시간적분법)

  • Jung, Rae-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.99-106
    • /
    • 2006
  • The Real-Time Hybrid Test system presented in this paper is based on the pseudodynamic test method, and it combines physical testing with model-based simulation. The system is designed to achieve a rate of loading that is significantly higher than that of a conventional pseudodynamic test approaching the real-time response of a structure subjected to earthquake loads. To provide robust computation environment for the analysis of many degree-of-freedom structures, the system adopts an implicit time integration scheme in the model-based simulation. This paper presents an overview of the developed system and numerical simulations that were conducted to evaluate the performance of the computation scheme adopted here. Results of these studies have demonstrated the good performance of the computation scheme for real-time multiple-degree-of-freedom tests.

Study of compressive behavior of triple joints using experimental test and numerical simulation

  • Sarfarazi, Vahab;Wang, Xiao;Nesari, Mojtaba;Ghalam, Erfan Zarrin
    • Smart Structures and Systems
    • /
    • v.30 no.1
    • /
    • pp.49-62
    • /
    • 2022
  • Experimental and discrete element methods were used to investigate the effects of triple joints lengths and triple joint angle on the failure behavior of rock mass under uniaxial compressive test. Concrete samples with dimension of 20 cm × 20 cm × 5 cm were prepared. Within the specimen, three imbedded joint were provided. The joint lengths were 2 cm, 4cm and 6 cm. In constant joint lengths, the angle between middle joint and other joints were 30°, 60°, 90°, 120° and 150°. Totally 15 different models were tested under compression test. The axial load rate on the model was 0.05 mm/min. Concurrent with experimental tests, the models containing triple joints, length and joint angle are similar to the experiments, were numerical by Particle flow code in two dimensions (PFC2D). Loading rate in numerical modelling was 0.05 mm/min. Tensile strength of material was 1 MPa. The results show that the failure behaviors of rock samples containing triple joints were governed by both of the angle and the length of the triple joints. The uniaxial compressive strengths (UCS) of the specimens were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behavior of discontinuities is related to the number of the induced tensile cracks which are increased by decreasing the joint length. Along with the damage failure of the samples, the acoustic emission (AE) activities are excited. There were only a few AE hits in the initial stage of loading, then AE hits rapidly grow before the applied stress reached its peak. In addition, every stress drop was accompanied by a large number of AE hits. Finally, the failure pattern and failure strength are similar in both methods i.e., the experimental testing and the numerical simulation methods.

Behavior of F shape non-persistent joint under experimental and numerical uniaxial compression test

  • Sarfarazi, Vahab;Asgari, Kaveh;Zarei, Meisam;Ghalam, Erfan Zarrin
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.199-213
    • /
    • 2022
  • Experimental and discrete element approaches were used to examine the effects of F shape non-persistent joints on the failure behaviour of concrete under uniaxial compressive test. concrete specimens with dimensions of 200 cm×200 cm×50 cm were provided. Within the specimen, F shape non-persistent joint consisting three joints were provided. The large joint length was 6 cm, and the length of two small joints were 2 cm. Vertical distance between two small joints change from 1.5 cm to 4.5 cm with increment of 1.5 cm. In constant joint lengths, the angle of large joint change from 0° to 90° with increments of 30°. Totally 12 different models were tested under compression test. The axial load rate on the model was 0.05 mm/min. Concurrent with experimental tests, numerical simulation (Particle flow code in two dimension) were performed on the models containing F shape non-persistent joint. Distance between small joints and joint angles were similar to experimental one. the results indicated that the failure process was mostly governed by both of the Distance between small joints and joint angles. The axial loading rate on the model was 0.05 mm/min. The compressive strengths of the samples were related to the fracture pattern and failure mechanism of the discontinuities. Furthermore, it was shown that the compressive behaviour of discontinuities is related to the number of the induced tensile cracks which are increased by increasing the joint angle. In the first, there were only a few acoustic emission (AE) hits in the initial stage of loading, and then AE hits rapidly grow before the applied stress reached its peak. Furthermore, a large number of AE hits accompanied every stress drop. Finally, the failure pattern and failure strength are similar in both approaches i.e., the experimental testing and the numerical simulation approaches.

Development of Hydrologic Simulation Model for the Prediction of Long-Term Runoff from a Small Watershed

  • 고덕구;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.33-46
    • /
    • 1990
  • Abstract Over 700/0 of the rural land area in Korea is mountainous and small watersheds provide most of the water resources for agricutural use. To provide an appropriate tool for the agricultural water resource development project, SNUA2, a mathematical model for simulating the physical processes governing the precipitation-runoff relationships and predicting the storm and long-term runoff quantities from the small mountainous watersheds was developed. The hydrological characteristics of small mountainous watersheds were reviewed to select appropriate theories for the simulation of the runoff processes, and a deterministic and distributed model was developed. In this, subsurface flows are routed by solving Richard's two dimensional equation, the dynamics of soil moisture contents are simulated by the consideration of phenological factors of canopy plants and surface flows are routed by solving the kinematic wave theory by numerical analysis. As a result of an application test of the model to the Sanglim watershed, peak flow rates of storm runoff were over-estimated by up to 184.2%. The occurence time of peak flow and total runoff volume of storm runoffs simulated were consistent with observed values and the annual runoff volumes were simulated in the error range of less than 5.8%.

  • PDF

Numerical Simulation of Flow around a Fixed Semi-submersible Offshore Structure Using the Modified Marker-density Method (수정된 밀도함수법을 이용한 고정된 반잠수식 해양구조물 주위 유동의 수치시뮬레이션)

  • Ha, Yoon-Jin;Lee, Young-Gill;Jeong, Kwang-Leol;Yang, In-Jun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • It is important to research and understand the physical phenomenon around a semi-submersible offshore structure on waves and currents because the wave run-up and load occurs owing to the waves and currents. In this study, the numerical simulations are performed about flow around a fixed semi-submersible offshore structure. The Modified Marker-density method is adopted in the present computation procedure, this method is one of the various methods to define the free-surface. The present computation results are compared with existing experimental and numerical simulation(VOF method) results. And, the computation results are relatively coincident with the existing results of model test and numerical simulation by VOF method.

3D Nonlinear Fully Coupled Simulation of Cable and Tow-fish System (케이블-수중 예인체 시스템의 3차원 비선형 완전 연성해석)

  • Go, Gwangsoo;Lee, Euntaek;Ahn, Hyung Taek
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.458-467
    • /
    • 2016
  • In this paper, a strongly coupled method for investigating the interaction between a cable and tow-fish is presented. The nodal position finite element method was utilized to analyze the nonlinear cable dynamics, and 6DOF equations of motion were employed to describe the 3D rigid body motion of the tow-fish. Combining cable and tow-fish systems into a single formulation allowed the two nonlinear systems to be strongly coupled into a unified nonlinear system. This strongly coupled system was numerically integrated in the time domain using a predictor/multi-corrector Newmark algorithm. To demonstrate the validity, efficacy, and applicability of the current approach, two different scenarios (virtual and sea trial) were simulated, and the simulation results were validated using the physical plausibility and the sea trial test.

A Systems Engineering Approach to Multi-Physics Load Follow Simulation of the Korean APR1400 Nuclear Power Plant

  • Mahmoud, Abd El Rahman;Diab, Aya
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-15
    • /
    • 2020
  • Nuclear power plants in South Korea are operated to cover the baseload demand. Hence they are operated at 100% rated power and do not deploy power tracking control except for startup, shutdown, or during transients. However, as the contribution of renewable energy in the energy mix increases, load follow operation may be needed to cover the imbalance between consumption and production due to the intermittent nature of electricity produced from the conversion of wind or solar energy. Load follow operation may be quite challenging since the operators need to control the axial power distribution and core reactivity while simultaneously conducting the power maneuvering. In this paper, a systems engineering approach for multi-physics load follow simulation of APR1400 is performed. RELAP5/SCDAPSIM/MOD3.4/3DKIN multi-physics package is selected to simulate the Korean Advanced Power Reactor, APR1400, under load follow operation to reflect the impact of feedback signals on the system safety parameters. Furthermore, the systems engineering approach is adopted to identify the requirements, functions, and physical architecture to provide a set of verification and validation activities that guide this project development by linking each requirement to a validation or verification test with predefined success criteria.

Landscape Evaluation of Rural Stream based on the Factor Analysis of Visual Preference (시각적 선호요인 분석을 통한 농촌 소하천 경관평가에 관한 연구)

  • Kim, Sung-Keun;Cho, Woo-Hyun;Im, Seung-Bin
    • Journal of Korean Society of Rural Planning
    • /
    • v.5 no.1 s.9
    • /
    • pp.35-44
    • /
    • 1999
  • The purpose of this study is to find the bi-polar adjectives for rural stream landscape evaluation by the semantic differential scale and to suggest the major determinants of visual preference in rural stream landscapes. For this, the bi-polar adjectives for rural stream landscape evaluation was found by the method of the reliability test, and the spatial image was analyzed by the factor analysis. The level of visual preference was measured by slide simulation test, and these data were analyzed by the multiple regression. The major findings of this study can be summarized as follows : 1) Of the bi-polar adjectives expressing psychological and physical characteristics, the hi-polar adjectives which demonstrated reliability and consistency run as follows : Bi-polar adjectives expressing psychological characteristics : 'calm-bustling', 'unfamiliar-familiar', 'still-active','depressing-brisk', 'discomfortable-comfortable', 'suppressed-free', 'lifeless-living', 'quiet-noisy', 'unpleasant-pleasant'. Bi-polar adjectives expressing physical characteristics : 'artificial-natural', 'narrow-wide', 'rocky-not rocky', 'desolate-fertile', 'dirty-clean', 'enclosed-open', 'flat-steep', 'not gravelly-gravelly', 'thicketed-not thicketed', 'not weedy-weedy'. 2) Two factors, the harmony and the movement, were derived from the factor analysis for the psychological variables. Three factors, the naturalness, the rock, and the vegetation, were derived from the factor analysis for the physical variables. 3) Rural stream landscape types were classified into four types by the multi-dimensional scaling method. Type III, IV obtained higher rank of visual preference and type I, II obtained lower. 4) For all types, the factors determining the level of visual preference were found to be the harmony, the naturalness, and the vegetation. The visual preference determinants of rural stream landscape need to be considered in improving or restoring the rural stream landscapes.

  • PDF