• 제목/요약/키워드: physical mechanism

검색결과 1,336건 처리시간 0.03초

Development of walking assist system for the people with lower limb-disability

  • Kim, Seok-Hwan;Izumi, Keisuke;Koujina, Yasuhiro;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1495-1499
    • /
    • 2003
  • There is some equipment that helps user to exercise and to walk. But almost all equipments require some physical strength of their muscles. So we developed a system that could assist walking action of the people with lower-limb disability. The system called as walking stand adopted the balancing mechanism which assures the stable walking, and the 4 link-based mechanism that had 2 degrees of freedom on each leg. The walking stand uses four motors and has two sets of the special link-structure to simulate the human walking mechanism. With our system, even serious disabled with lower-limb disability may enjoy walking rehabilitation. And by adjusting the power, it can be used as the walking assistant mechanism instead of conventional wheelchairs. Experiments showed that our walking stand is applicable to the rehabilitation and also to the mobile device in our daily life for those people who do not have enough physical ability to walk by themselves.

  • PDF

BASIC MECHANISM OF ROBOT ADAPTED TO PHYSICAL PROPERTIES OF TOMATO PLANT

  • Kondo, N.;Monta, M.;Shibano, Y.;Mohri, K.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.840-849
    • /
    • 1993
  • In this paper, it is reported that manipulator and hand-required for harvesting tomato were studied. At first, basic physical properties of tomato plant were investigated such as position of fruit, length of stems and leaves, width between ridges and son on . Secondly , basic mechanism of articulate manipulators with 5 to 7 degree of freedom were investigated by using evaluation indexes such as operational space, measure of manipulatability , posture diversity and so on. From the results, an articulate manipulator with 7 degrees of freedom was selected and the manipulator was manufactured as a trial according to the mechanism. Thirdly , physical properties about fruit and peduncle of tomato were also researched such as diameter, length , picking force and so on. Based on the properties , tomato harvesting hand with absorptive pad were also made as a trial. Finally, after the hand was attached to the manipulator, harvesting experiment was done in greenhouse . It was observed th t the robot could harvest satisfactorily , not only since the robot adapted to physical properties of tomato plant was manufactured but also since phyllotaxis of tomatoes was so methodical that all fruit clusters emerged in the same direction.

  • PDF

지반함몰 모형실험 연구동향 및 적용방안 고찰 (Trend of Physical Modelling For Ground Subsidence And Study of Its Application)

  • 정성윤;정영훈;김동수
    • 한국방재안전학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-10
    • /
    • 2017
  • 근래에 들어 증가하고 있는 도심지 지반함몰 사고는 사회적 이슈가 되고 있으며 이로 인해 최근 관련 법안이 발의 되었다. 지반함몰은 수많은 원인인자들의 복합적 작용으로 발생하므로 수치해석적 기법의 적용에 한계점이 존재한다. 이로 인해 지반함몰 메커니즘 규명 연구는 주로 모형실험을 이용하여 진행되었다. 선행 연구들은 상하수도관 파열로 인한 지반함몰 모사에 초점이 맞추어져 있으며, 지하수 흐름, 지반 굴착공사 등 다양한 원인에 의해 발생하는 지반함몰에 대한 연구가 부족한 실정이다. 또한 기존 수행된 대부분의 모형실험은 1 g 상태의 모형실험이며, 지반함몰 메커니즘 평가 시 지반의 현장 구속응력을 고려할 수 없다. 따라서 본 논문에서는 모형실험을 이용한 지반함몰 거동 평가에 대한 선행 연구동향들을 고찰하여 보다 다양한 환경 조건을 모사할 수 있는 기법들에 대해 논의하였다. 또한 본 연구에서는 더 신뢰성이 있는 지반함몰 메커니즘 평가 기법으로서 원심모형실험기법을 제시하였다. 마지막으로 본 연구에서는 지반안정성평가에 지반함몰 메커니즘에서 사용한 모형실험 기법을 적용할 것을 제시했다.

상완견관절의 안정적 구조에 관한 연구 (The study of stabilizing structure of the glenohumeral joints)

  • 이진희;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.433-444
    • /
    • 2000
  • The purpose is paper was to discuss current concepts related to anatomic stabilizing structures of the shoulder joint complex and their clinical relevance to shoulder instability. The clinical syndrome of shoulder instability represents a wide spectrum of symtoms and signs which may produce various levels of dysfunctions, from subtle subluxations to gross joint instability. The glenohumeral joint attains functional stability through a delicate and intricate interaction between the passive and active stabilizing structures. The passive constraints include the bony geometry, glenoid labrum, and the glenohumeral joint capsuloligaments structure. Conversely, the active constraints, also referred to as active mechanism, include the shoulder complex musculature, the projprioceptive system, and the musculoligamentous relationship. The interaction of the active and passive mechanism which provide passive and active glenohumeral joint stability will be throughtly discussed in this paper

  • PDF

원적외선의 인체작용메카니즘 (Mechanism of Far-infrared how to affect the human body)

  • 김재윤;박영한;박돈목;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.477-482
    • /
    • 2001
  • Until now, it has not been well known for Far-infrared(FIR) how to affect to the human body. We introduced and presumed the mechanism of FIR based on molecular biology in this study, as below. The human body is composed of proteins which get easily changed by a thermal factor (about 42 $^{\circ}$C over). FIR with low temperature can deeply penetrate on the human body composed things without troublesome, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). When FIR penetrated on the human body, it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FIR's receptors in the body, it colud be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process, and heat shock protein.

  • PDF

경피신경전기자극과 초음파가 전기생리학적 반응에 미치는 영향 (Effects on Electrophysiologic Responses to the Transcutaneous Electrical Nerve Stimulation and Ultra Sound)

  • 백수정;이미애;김진상;최진호
    • The Journal of Korean Physical Therapy
    • /
    • 제12권1호
    • /
    • pp.49-56
    • /
    • 2000
  • The purpose of this study was to investigate the influnce of afferent stimuli, transcutaneous electrical nerve stimulation and ultra sound, on the electrdiagnostic study of normal subjects. Electrodiagnostic study was performed before and after the application of afferent stimulation of the right popliteal fossa on 18 healthy female volunteers. After the transcutaneous electrical nerve stimulation, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. After the ultra sound, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. Tibial nope F-wave and motor nerve shows prolonged latency after TENS and US (p<0.01). Ultrasound may have a similar mechanism of action compared to transcutaneous electrical nerve stimulation by having localized inhibitory effects of the peripheral nerve. However, further investigation is needed to assess their mechanism of action and the precise relevance of stimulation modality.

  • PDF

The Effects of Circuit Training and Circuit Training with Whole Body Vibration on Pulmonary Function in Adolescent

  • Jun, Hyun ju;Jeong, Chan Joo;Yang, Hoe Song;Jeong, Ye rim;Jegal, Hyuk;Yoo, Young Dae
    • 국제물리치료학회지
    • /
    • 제6권2호
    • /
    • pp.902-907
    • /
    • 2015
  • The purpose of this study was to parallel circuit training and circuit training with sonic systemic mechanism was to compare the differences in pulmonary function and chest expansion in adult men. This study was performed on 20 subjects. 20 subjects were divided into two groups; Circuit training group(n=10), Circuit training with sonic systemic mechanism(n=10). Both of the group performed the exercise 3 times a week for 5 weeks. The data was analyzed by the Repeated t-test for comparing before, during and after changes of factors in each group and the Independent t-test for comparing the between groups. The result are as follows. Circuit training group was statistically significant difference FVC, FEV1/FVC(p<.05), Circuit training with sonic systemic mechanism group was statistically significant difference PEF, VC in pulmonary function(p<.05). Circuit training group was statistically significant difference FEV1/FVC of between the two group in pulmonary function(p<.05). Circuit training group and circuit training with sonic systemic mechanism group was statistically significant difference in chest expansion(p<0.05) and there was no statistically significant difference of between the two group in chest expansion(p>.05).

Physical mechanism of gamma-ray bursts: recent breakthroughs

  • 엄정휘
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.39.1-39.1
    • /
    • 2018
  • Although it is agreed that the gamma-ray bursts (GRBs) invoke highly relativistic jets with bulk Lorentz factors of a few hundreds, the exact physical mechanism producing such powerful gamma-rays still remains debated. Three outstanding and important questions in the field concern (1) the composition of GRB jets (i.e., matter-dominated vs Poynting-flux-dominated), (2) the involved radiative process responsible for the observed gamma-rays (i.e., synchrotron mechanism vs photospheric radiation), and (3) the distance of the emitting region from the central engine where the prompt gamma-rays are released (i.e., ~10^12 cm vs 10^14 cm vs 10^16 cm). I will present recent important breakthroughs that we have made, which answer these three questions.

  • PDF

쥐의 적출 대동맥에 자외선 조사로 유발된 photorelaxation 기작의 생리학적 특성 (Physiological characterization of mechanism on UV light-induced photorelaxation in isolated rat aorta)

  • 이한기;홍용근;김경
    • The Journal of Korean Physical Therapy
    • /
    • 제15권2호
    • /
    • pp.146-156
    • /
    • 2003
  • Isolated rat thoracic aorta which is pharmacologically precontracted by phenylephrine induces photorelaxation when exposed to long wave length UV-light. The aim of the present study was to characterize the mechanism of UV-light induced by photorelaxation in the rat aorta. 1. UV light relaxed both endothelium-intact and -denuded rat aortic rings contracted by phenylephrine. The magnitude of relaxation on UV light was dependent on the exposure time and slightly greatly in endothelium-denuded rings than in endothelium-intact preparations. 2. L-NAME (10 nM - 100 $\mu$M) but not D-NAME completely inhibited the photorelaxation in a concentration dependent manner. 3. The UV-induced relaxation was inhibited by methylene blue (1 - 100 uM), and verapamil (100 nM), and removal of extracellular $Ca^{2+}$. In contrast, UV-light induced photorelaxation was potentiated by $N^{w}$-nitro-L-arginine (L-NNA) treatment. These results suggest that UV light-induced photorelaxation may be due to nitric oxide from exogenously administered L-arginine as well as endogenous nitric oxide donors such as amino acid and arginine derivatives

  • PDF

Corrosion behavior and mechanism of CLAM and 316L steels in flowing Pb-17Li alloy under magnetic field

  • Xiao, Zunqi;Liu, Jing;Jiang, Zhizhong;Luo, Lin;Huang, Qunying
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.1962-1971
    • /
    • 2022
  • The liquid lead-lithium (Pb-17Li) blanket has many applications in fusion reactors due to its good tritium breeding performance, high heat transfer efficiency and safety. The compatibility of liquid Pb-17Li alloy with the structural material of blanket under magnetic field is one of the concerns. In this study, corrosion experiments China low activation martensitic (CLAM) steel and 316L steel were carried out in a forced convection Pb-17Li loop under 1.0 T magnetic field at 480 ℃ for 1000 h. The corrosion results on 316L steel showed the characteristic with a superficial porous layer resulted from selective leaching of high-soluble alloy elements and subsequent phase transformation from austenitic matrix to ferritic phase. Then the porous layers were eroded by high-velocity jet fluid. The main corrosion mechanism of CLAM steel was selective dissolution-base corrosion attack on the microstructure boundary regions and exclusively on high residual stress areas. CLAM steel performed a better corrosion resistance than that of 316L steel. The high Ni dissolution rate and the erosion of corroded layers are the main causes for the severe corrosion of 316L steel.