• Title/Summary/Keyword: physical length

Search Result 2,013, Processing Time 0.026 seconds

Effects of Removable Ankle-Foot Orthosis in Chronic Patients With Hemiplegia During Gait Training: A Pilot Study

  • Kim, Hyung-geun;Oh, Yong-seop
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.91-97
    • /
    • 2015
  • This study was conducted to investigate the effects of the removable ankle-foot orthosis (RAFO) which was developed to improve the gait of stroke patients. The subjects of this study were five stroke patients who agreed to participate in this study by signing a written consent form. To verify gait improvement after wearing the orthosis, a Timed Up and Go test and Functional Gait Assessment were performed, and spatiotemporal gait variables such as gait speed, cadence, stride length, double limb support, and the efficient gait test of body sway angle were performed. For every variable, the differences prior to and after wearing the RAFO were compared using the Wilcoxon signed-rank test. Every gait variable improved significantly after wearing the RAFO compared to prior to wearing it. The pilot study will enhance future efforts to evaluate orthotic function objectively during gait in stroke patients.

The Effects of Using Cane on Hemiplegic Gait of Strock Patients (뇌졸증으로 인한 편마비 보행의 시간적 공간적 요소 분석: 지팡이가 보행에 미치는 영향)

  • Lee hyun-ok;Kim byung-jo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.372-383
    • /
    • 2003
  • The purpose of this study was to assess of cane use on the hemiplegic gait of strock patients in temporal and spatial variables. Subjects were thirteen including 8 men and 5 women. They could walk independently without cane, To compare the effect of walking with and without a cane, temporal and spatial variables was measured using GAITRite. Cane walking demonstrated increased stance time on the affected side, and swing time, step length on the sound side were increased, and base of support was decreased. In conclusion, hemiplegic gait pattern of strock patients were improved with cane than those not using a cane.

  • PDF

Relief Effects by Post - Isometric Relaxation for Myofascial Pain Syndrome (근막동통 증후군에 대한 PIR의 치료효과)

  • Park, Ji-Whan;Kim, Bong-Soo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.7-15
    • /
    • 1997
  • The purpose of this study was to exame the pain relief effects of myofascial pain syndrome patient by Post-Isometric Relaxation. From July, 1996 to January, 1997, PIR was applied to myofascial pain syndrome associated with musculoskelatal lesions and was examed on 17 muscles in 98 patients at Sun General Hospital, Taejon city. The results of this study were as follows ; 1. Immediate pain relief group was 58(59%). 2. Only tenderness relief group was 24(25%). 3. No effect group was 16(16%). These results could be confirmed that the increased tension of the affected muscles with the resulting pain relieved by restoring the full stretch length of the muscle by PIR.

  • PDF

Relief Effects by Post-Isometric Relaxation for Myofascial Pain Syndrome (근막동통 증후군에 대한 PIR의 치료효과)

  • Park, Ji-Whan;Kim, Bong-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.1
    • /
    • pp.255-263
    • /
    • 1997
  • The purpose of this study was to examed the pain relief effects of myofascial pain syndrome patient by post-isometric relaxation. From July, 1996 to January, 1997, PIR was applied to myofascial pain syndrome associated with musculoskelatal lesions and was examed on 17 muscles in 98 patients at Sun General Hospital, Taejon city. The results of this study were as follows ; 1. Immediate pain relief group was 58(59%). 2. Only tenderness relief group was 24(25%). 3. No effect group was 16(16%). These results could be confirmed that the increased tension of the affected muscles with the resulting pain relieved by restoring the full stretch length of the muscle by PIR.

  • PDF

Golf driver shaft variability on ball speed, head speed and fly distance (골프 드라이버 샤프트의 가변성이 타구속도, 헤드스피드 및 비거리에 미치는 영향)

  • Jung, Chul;Park, Woo-Yung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.273-283
    • /
    • 2018
  • The purpose of this study is to analyze the optimum driver selection according to shaft intensity, shaft length and shaft weight that are determining factors of driver shot. To achieve the above purpose, the subject were participate with handicap zero 10 male pro golfer and mean score 90(handicap about 18) amateur 10 male golfer. The used club limited number 1 driver, we tested 24 driver which is shaft intensity, length, weight, total weight and swing weight. Dependent variable was strike ball speed, flying distance and head speed. The findings can be summarized as follows. First, There is a significantly difference in CPM. Ball speed, head speed and flying distance according to driver shaft intensity were found to be the best when CPM is 230<. Second, There is a significantly difference in shaft length. Ball speed, and head speed according to driver shaft length were found to be the best at 46 inch and flying distance were found to be the best at 45 inch. Third, There is not significantly difference in SW. Ball speed and flying distance according to driver shaft weight were found to be the best with 65g. In the case of head speed, it was the fastest with 50g shaft. Four, total variables were significantly difference between in pro and amateur golfer. In conclusion, there would be differences in individual physical condition but the best result was found with a driver of CPM 230<, shaft length 46inch, and shaft weight 65g.

The Effects of Visual Flow Speed's Modulation-Based Virtual Reality Program on Gait Function in Stroke Patients (시각 흐름 속도에 따른 가상현실 프로그램이 뇌졸중 환자의 보행에 미치는 영향)

  • Kang, Hyung-Kyu;Chung, Yi-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.247-253
    • /
    • 2012
  • The purpose of this study was to evaluate the effects of a visual flow speed's modulation-based VR(virtual reality) program on gait function in stroke patients. Thirty one stroke patients were randomly selected at Dep. of Rehabilitation medicine of M hospital in Seoul. We carried out the gait analysis by dividing them with four conditions : one condition had applied without the visual flow modulation-based VR and another had done three visual flow speed's modulation-based VR(0.25, 1, 2 times). The gait analysis was used with GaitRite system. The data were collected using gait velocity, cadence, stride length, step length, single support time, and double support time during treatment. The results were as follows. First, the slow visual flow(0.25 times)-based VR program on the condition was significant decrease gait velocity, cadence, stride length, step length and increase single support time, double support time(p<.05). Second, the fast visual flow(2 times)-based VR program on the condition was significant increase gait velocity, cadence, stride length, step length, single support time on paretic lower limb and decrease single support time on non-paretic lower limb, double support time(p<.05). Third, the normal visual flow(1 times)-based VR program on the condition was not significant differ gait velocity, cadence, stride length, step length, single support time, double support time. In conclusion, the visual flow speed's modulation-based VR program improves gait function in chronic stroke patients.

The Effect of Microcurrent Stimulation on Wound Healing in Rat (미세전류전기자극이 흰쥐의 창상치유에 미치는 영향)

  • Oh, Hye-Jin;Kim, Jung-Woo;Park, Jang-Sung
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.6 no.1
    • /
    • pp.43-55
    • /
    • 2008
  • The purpose of this study was to investigate the effect of microcurrent stimulation intensity($50{\mu}A,\;100{\mu}A,\;300{\mu}A$ - 5 pps pulse frequency was same) on wound healing in rat. Sixty male Korean rats were randomly divided into 4 groups of 15 for 4 different treatment protocols(none-control group, $50{\mu}A,\;100{\mu}A,\;300{\mu}A$ experimental groups). Experimental 20 mm linear wound were made and all animals in the experimental groups were received microcurrent stimulation once a day for 20 minutes until sacrifice days(1st day, 3rd day, 6th day). A vernier caliper was used to measure a wound healing length and an optical microscope was used to determine any histological changes. The repeated measures two-way ANOVA was used for statistical differences in wound healing length. Experimental results were as follows: 1. In the examination with the naked eye, all groups showed similar changes until 1st day. But from 3rd day, a little intercellular fluid soaked through wound region in control group. In experimental groups, little intercellular fluid soaked through wound region, and swelling and redness did not appear. 2. Wound length of experimental $50{\mu}A$ group was significantly decreased than control group(p<0.001). And in the aspect of application period, wound length was significantly decreased in 3th, 6th day than 1st day and 6th day than 3th day (p<0.001). In conclusion, it has been found that the microcurrent stimulation had a positive effect on wound healing. And $50{\mu}A$ stimulation intensity was more effective than other intensities($100{\mu}A,\;300{\mu}A$) in wound healing. Also, low-intensity microcurrent stimulation was more effective on the purpose of wound healing.

  • PDF

Apparel Sizing System for Obese Men in There 20s (20대 비만 남성을 위한 의복 사이즈 체계에 관한 연구)

  • Yoon, Ji-Won;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.3
    • /
    • pp.449-459
    • /
    • 2011
  • The purpose of this study is investigate the feature of the body shape of obese males and to propose a new apparel sizing system considering the body size of obese men through an the analysis of the body measurement of obese men in their twenties as reported in the 'Fifth Korean National Physical Standard Reports'. For this study, a new apparel sizing system for casual wear was proposed for obese men in their twenties after a body measurement of 159 obese men in their 20s with a BMI of 25 and over as reported in the 'Fifth Korean National Physical Standard Reports' conducted by SIZEKOREA. This study sought to investigate the features of obese men's bodies by comparing the body shape between obese men and ordinary men. The result of shows that width, depth and circumference items influencing the width size when producing clothes are larger in the case of an obese body shape than an ordinary body shape, and that the stature, total length, arm length and outside leg length influencing the length size are similar between an obese body shape and an ordinary body shape. Therefore, it was confirmed that an apparel sizing system specializing in clothes for obese customers is required. As a result of this study of the features of body shape, the control dimensions for such an apparel sizing system were determined to be the stature and chest circumference of upper garments and the stature and waist circumference(omphalion) for lower garments. The interval between the sizes was 5cm for the stature and was irregular for the chest and waste circumference. Consequently, 8 sizes were proposed for upper garments and 9 sizes were proposed for lower garments.

Effect of Aquatic Walking Exercise on Gait and Balance Parameters of Elderly Women (수중걷기운동이 여성노인의 보행 및 평형능력에 미치는 영향)

  • Kang, Ki-Joo;Lee, Joong-Sook;Yang, Jeong-Ok;Park, Joon-Sung;Han, Ki-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • Objective: The purpose of this study is to analyze the effects of aquatic walking exercise on gait and balance parameters of elderly women. Method: 15 elderly people were recruited for this study (age: 73.20±5.19 yrs, height: 153.87±3.36 cm, mass: 60.33±5.73 kg). All variables were measured using Gaitview AFA-50. The variables were the heel contact time ratio, gait angle, and M/P change ratio for gait patterns and ENV, REC, RMS, Total Length, TLC, Sway velocity, and Length/ENV for balance abilities. A paired t-test and the Wilcoxon signed-rank test were carried out to verify the differences in the test scores after participating in the water walking program. The significance level for all statistical analyses was set to α=.05. Results: As for the changes in their walking function after the exercise, heel contact time ratio (p<.01) showed a statistical significance, while gait angle and M/P change ratio did not reveal statistically significant differences. In the test of balance ability on both feet and with eyes opened, statistical significance was found in ENV, REC, RMS, TLC (p<.01), and sway velocity (p<.05), while the test with eyes closed showed statistical significance in length/ENV as well as ENV, REC, RMS, sway velocity (p<.01) TLC, and total length (p<.05). As for the single-leg stance balance ability, ENV and REC revealed statistically significant differences. Conclusion: These results show that water walking is effective for improving the function of the ankle flexor muscles, providing stability to the ankle joint during walking and helping efficient walk. In addition, it is also expected to help prevent falls due to loss of balance by improving the stability of lower extremity muscles and trunk.

Effect of Saddle to Pedal Length in Kayak Ergometer on Rowing Motion and EMG Activation in Elite Kayak Players (엘리트 카약 선수들의 에르고미터를 이용한 로잉 동작 시 안장과 페달의 거리가 로잉 패턴 및 근 활성도에 미치는 영향)

  • Ryue, Jae-Jin;Nam, Ki-Jung;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • The purpose of this study was to identify the saddle to pedal length contributing to successful performance in kayak using a kayak ergometer. Ten male elite kayak players participated in this study. players were tested on the kayak ergometer which was varied saddle to pedal length by the knee flexion angle(90deg; 120deg; 150deg) to measure stroke frequency, paddling amplitude, joint angle, RoM and angular velocity, foot pressure and force, iEMG using the 3D motion system, foot pressure system and EMG wireless system. At a results, rowing at 120deg on knee flexion angle showed higher stroke frequency and paddling amplitude than other knee flexion angles. RoM at upper extremity showed not significant difference between knee flexion angles. But there were significant differences in thorax and pelvis rotation RoM, knee flexion-extension RoM in each condition. In addition, foot pressure, force and iEMG were significantly different in knee flexion angles. Study showed that changed of saddle to pedal length affected rowing performance kinds of stroke frequency, paddling amplitude. The most important thing, increased range of motion in pelvic and thorax has occurred by force that generated foot-bar to seat. Not only that, but it seems to be attributed to a technical adaptation developed to maximum rowing performance.