• Title/Summary/Keyword: physical distribution center

Search Result 391, Processing Time 0.031 seconds

Structural and radiological characterization of irradiated RBMK-1500 reactor graphite

  • Lagzdina, Elena;Lingis, Danielius;Plukis, Arturas;Plukiene, Rita;Germanas, Darius;Garbaras, Andrius;Garankin, Jevgenij;Gudelis, Arunas;Ignatjev, Ilja;Niaura, Gediminas;Krutovcov, Sergej;Remeikis, Vidmantas
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.234-243
    • /
    • 2022
  • This study aims to characterize the irradiated RBMK-1500 nuclear graphite in terms of both structural and radiological properties. The experimental results of morphological and structural analysis of the irradiated graphite samples by using SEM, Raman spectroscopy as well as the theoretical evaluation of primary displacement damage are presented. Moreover, the experimental and theoretical evaluation of the neutron flux is provided and the presence of several γ emitters in the analyzed graphite samples is assessed. Furthermore, the improved version of rapid analysis method for 14C activity determination is applied and the experimentally obtained results are compared with calculated ones. Results indicate that structural changes are uniform enough in all the analyzed samples. However, the distribution of radionuclides is non-homogeneous in the irradiated RBMK-1500 reactor graphite matrix. The comprehensive understanding of both structural and radiological characteristics of nuclear graphite is very important when dealing with decision about irradiated graphite waste management strategy or treatment options prior to its final disposal.

The Immediate Effects of Elastic Taping on Center of Pressure and Foot Pressure Distribution

  • Jung-Hee Kim;Jong-Ho Kook;Sang-Mi Lee;Eun-Bin Ko;Song-Yi Han;Yeon-Jeong Kim;Byeong-Jun Min
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.23-30
    • /
    • 2024
  • Purpose: Ankle instability is a common issue in both daily activities and sports, often leading to recurrent injuries. Elastic taping is a non-pharmacological intervention used to improve ankle stability. This study aimed to investigate the immediate effects of elastic taping on ankle stability, center of pressure (COP) movement, and foot pressure distribution. Methods: A single-group pre-posttest design was employed, with 30 participants included in the study. Plantar pressure and COP parameters were measured before and after the application of elastic taping. Taping was administered in three distinct patterns to enhance ankle stability. Results: Immediate effects of elastic taping were evident in COP parameters. Following taping application, there was a significant decrease in COP total displacement, COP area, and COP velocity. However, no significant changes were observed in plantar pressure parameters. Conclusion: The application of elastic taping in this study demonstrated immediate effects on ankle stability and COP parameters, indicating its potential as a viable intervention for improving balance. Further research with larger sample sizes and long-term follow-up is needed to elucidate the sustained effects of elastic taping on ankle stability.

A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF

The Effect of Auditory and Visual Feedback on Symmetric Weight Bearing with Hemiplegia (성인 편마비 환자에서 시각 되먹임과 청각 되먹임이 체중 지지에 미치는 효과)

  • Park, Sung-Ill;Lee, Heong-Hun;Shin, Sang-Yong
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.3
    • /
    • pp.691-696
    • /
    • 1998
  • Objectives : Asymmetrical weight bearing during standing has been identified as a common problem in persons with hemiplegia. This study examined the effect of auditory and visual feedback on symmetric weight bearing with hemiplegia. Method: The intervention program was instituted for 10 min each day with a total of twelve treatment sessions. The machine which was used for this study is the Weight Balancer, OG GIKEN, WB-202, Japan Result: There was a significant improvement of symmetric weight distribution in auditory feedback group whereas the visual feedback group disclosed some improvement but not significantly. There was no significant change in control group. Conclusion: Results of this study suggest that an auditary feedback group can be more effective than visual feedback group or control group in helping the persons with hemiplegia achieve symmetric stance.

  • PDF

The Effects of Visual Biofeedback Information on Hyperextended Knee Control

  • Jung, Sung-hoon;Jeon, In-cheol;Ha, Sung-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.3
    • /
    • pp.162-167
    • /
    • 2021
  • Purpose: A hyperextended knee is described as knee pain associated with an impaired knee extensor mechanism. Additionally, a hyperextended knee may involve reduced position sense of the knee joint that decreases the individual's ability to control end-range knee extension movement. The purpose of this study was to investigate the effects of visual biofeedback information for plantar pressure distribution on knee joint angle and lower extremity muscle activities in participants with hyperextended knees. Methods: Twenty-three participants with hyperextended knees were recruited for the study. Surface electromyography signals were recorded for the biceps femoris, rectus femoris, gastrocnemius, and tibialis anterior muscle activities. The plantar pressure distribution was displayed and measured using a pressure distribution measuring plate. Knee joint angle kinematic parameters were recorded using a motion analysis system. The visual biofeedback condition was the point at which the difference between the forefoot and backfoot plantar foot pressure on the monitor was minimized. The Wilcoxon signed-rank test was used to determine the significance between the visual biofeedback condition and the preferred condition. Results: The knee joint angle was significantly decreased in the visual biofeedback condition compared to that in the preferred condition (p<0.05). The rectus femoris and gastrocnemius muscle activities were significantly different between the visual biofeedback and preferred conditions (p<0.05). Conclusion: The results of this study showed that visual biofeedback of information about plantar pressure distribution is effective for correcting hyperextended knees.

The Comparison of Plantar Pressure Distribution regarding the Extent of Hemineglect in Adult Hemiplegia (성인 편마비 환자의 편측 무시정도에 따른 족저압 비교)

  • Cha, Yong-Jun;Kim, Kyung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.43-51
    • /
    • 2010
  • Purpose : The purpose of this study was to compare plantar pressure distribution between affected side and unaffected side and to analyze plantar pressure distribution of affected side according to the extent of hemineglect in the adult hemiplegia. Methods : Twenty-five hemiplegia participated in this study. The analysis of plantar pressure distribution was conducted by the F-scan system, and the extent of hemineglect was evaluated with line-bisection test. While the subject walked about 10 meters in their comfortable speed the plantar pressure was evaluated and stored. Results : Total contact area, AP CoP trajectory, contact pressure of mid-foot of the affected side were significantly different from the unaffected side. Total contact area, AP CoP trajectory and contact pressure of mid-foot were smaller than those of unaffected side. In the comparison among the group according to the extent of hemineglect, AP CoP trajectory of subject who has severe hemineglect was significantly different from the patient that has no hemineglect and it was shorter than that of no hemineglect. Conclusion : The plantar pressure distribution was generally different between affected side and unaffected side and the hemineglect affected negatively the patient to move CoP forwardly while walking. Accordingly, it will help the clinician to understand the hemineglect which has an effect on abnormal walking and to intervent the hemiplegia who has a neglection to the affected side.

A Distribution Automation System Simulator for Training and Research

  • Gupta R. P.;Srivastava S. C.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.159-170
    • /
    • 2005
  • This paper presents the design and development of a scaled down physical model for power Distribution Automation (DA) system simulation. The developed DA system simulator is useful in providing hands-on experience to utility engineers / managers to familiarize with the DA system and gain confidence in managing the power distribution system from the computer aided distribution control center. The distribution automation system simulator can be effectively used to carry out further research work in this area. This also helps the undergraduate and graduate students to understands the power distribution automation technology in the laboratory environment. The developed DA simulator has become an integral part of a distribution automation lab in the Electrical Engineering Department at Indian Institute of Technology Kanpur in India.