• Title/Summary/Keyword: photoshop

Search Result 246, Processing Time 0.023 seconds

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block

  • Baek, Seung Woo;Ryu, Jae Sung;Jung, Cheol Hee;Lee, Joo Han;Kwon, Won Kyoung;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.26 no.2
    • /
    • pp.148-153
    • /
    • 2013
  • Background: C-arm fluoroscope has been widely used to promote more effective pain management; however, unwanted radiation exposure for operators is inevitable. We prospectively investigated the differences in radiation exposure related to collimation in Medial Branch Block (MBB). Methods: This study was a randomized controlled trial of 62 MBBs at L3, 4 and 5. After the patient was laid in the prone position on the operating table, MBB was conducted and only AP projections of the fluoroscope were used. Based on a concealed random number table, MBB was performed with (collimation group) and without (control group) collimation. The data on the patient's age, height, gender, laterality (right/left), radiation absorbed dose (RAD), exposure time, distance from the center of the field to the operator, and effective dose (ED) at the side of the table and at the operator's chest were collected. The brightness of the fluoroscopic image was evaluated with histogram in Photoshop. Results: There were no significant differences in age, height, weight, male to female ratio, laterality, time, distance and brightness of fluoroscopic image. The area of the fluoroscopic image with collimation was 67% of the conventional image. The RAD ($29.9{\pm}13.0$, P = 0.001) and the ED at the left chest of the operators ($0.53{\pm}0.71$, P = 0.042) and beside the table ($5.69{\pm}4.6$, P = 0.025) in collimation group were lower than that of the control group ($44.6{\pm}19.0$, $0.97{\pm}0.92$, and $9.53{\pm}8.16$), resepectively. Conclusions: Collimation reduced radiation exposure and maintained the image quality. Therefore, the proper use of collimation will be beneficial to both patients and operators.

The establishment of Digital Image Capture System(DICS) using conventional simulator (Conventional simulator를 이용한 Digital image capture system(DICS)의 구축)

  • Oh Taesung;Park Jongil;Byun Youngsik;Shin HyunKyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, flouroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and flouroscopic image. Methods and materials : We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record flouroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) Result : DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Conclusion : Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  • PDF

THE REMINERALIZATION ASPECT OF ENAMEL ACCORDING TO CHANGE OF THE DEGREE OF SATURATION OF THE ORGANIC ACID BUFFERING SOLUTION IN pH 5.5 (pH 5.5에서 유기산 완충용액의 포화도 변화에 따른 법랑질의 재광화 양상)

  • Park, Jin-Sung;Park, Sung-Ho;Park, Jeong-Won;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.96-105
    • /
    • 2010
  • The purpose of this study is to observe and compare the remineralization tendencies of artificial enamel caries lesion by remineralization solutions of different degree of saturations at pH 5.5, using a polarizing microscope and computer programs (Photoshop, Image pro plus, Scion Image, Excel). For this study, 48 sound permanent teeth with no signs of demineralization, cracks, or dental restorations were used. The specimens were immersed in lactic acid demineralization solution for 2 days in order to produce artificial dental caries that consist of surface and subsurface lesions. Each of 9 or 10 specimens was immersed in pH 5.5 lactic acid buffering remineralization solution of four different degrees of saturation (0.507, 0.394, 0.301, and 0.251) for 12 days. After the demineralization and remineralization, images were taken by a polarizing microscope (${\times}100$). The results were obtained by observing images of the specimens, and using computer programs, the density of caries lesions were est mated. While the group with the lowest degree of saturation (0.251) showed total remineralization feature from the surface to the subsurface of the lesion, the group with the highest degree of saturation (0.507) showed demineralization mainly on the surface of the lesion at the constant organic acid concentration 0.01 M and pH 5.5.

EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS (모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향)

  • Nam, Deuk-Lim;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n=15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of micro leakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p<0.05).

THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE (NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향)

  • Lim, Hyoung-Tae;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

EFFECT OF CAVITY DIVERGENCY ON CEMENT THICKNESS AND BOND STRENGTH OF RESIN INLAY (와벽 이개도가 레진 인레이의 시멘트 두께 및 접착 강도에 미치는 영향)

  • Cha, Yoon-Seog;Cho, Yong-Bum;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.619-627
    • /
    • 1996
  • There are increasing use of composite resin in the posterior teeth and the new indirect inlay technique was introduced for compensating much troubles faced in direct technique. Many researchers insisted that overall properties of restorative materials were enhanced by an additional curing but this technique still has a problems about using cement material. Resin inlay obtains retention force from friction and another adhesion to tooth structure. A shape of cavity preparation was noted but studies about cement thickness and bond strength with cavity divergency are rare. The purpose of this study is to assess the effect of cavity divergency on cement thickness and bond strength of resin inlay. Cavities, which divergency was $6^{\circ}$, $16^{\circ}$, and $26^{\circ}$ in each group, were prepared and their divergency was verified by Adobe Photoshop program through the image capture with stereo microscope and FlexCam. Inlays were fixed into the cavities with a resin cement, Superbond and were handled under chemical (in 75% ethanol for 24 hrs.) and thermal stress (500 cycles from $5^{\circ}$ to $55^{\circ}C$). MXT 70 (x400) was used for measuring the cement thickness and bond strength was evaluated with a universal testing machine. Following results were obtained : 1. The cement thickness in Mean (S.D.) were; 35.58 (10.31)${\mu}m$ in $6^{\circ}$ group, 35.97 (10.49)${\mu}m$ in $16^{\circ}$ group, and 41.43 (9.33)${\mu}m$ in $26^{\circ}$ group. But there was no significant difference between groups. 2. The bond strength in Mean (S.D.) were ; 33.18 (5.53)kg in $6^{\circ}$ group, 23.47 (13.40)kg in $16^{\circ}$ group, and 19.75 (10.48)kg in $26^{\circ}$ group. $6^{\circ}$ group showed significantly higher value compared to $16^{\circ}$ and $26^{\circ}$ groups (p<0.05). Although the results of this study indicate $6^{\circ}$ divergency will be good for resin inlay, cavity preparation with this type will have lots of difficulties in manufacturing, try-in, and cementation procedures, such as deformation. So it is concluded that $16^{\circ}$ divergent cavity preparation is recommended in resin inlay technique.

  • PDF

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Case report - Rehabilitation of a patient's smile by applying a simple digital smile design method on a complex clinical situation. (Case report - 복잡해 보이는 전악 구강 재건 케이스에 간단한 digital smile design을 적용하여 환자의 미소를 회복시켜 주기)

  • Im, Hyung gu
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.103-117
    • /
    • 2020
  • A beautiful smile has a great impact on the quality of life. It gives you confidence, and makes you function with a positive attitude, which will eventually bring the joy and happiness to daily lives. As dental practitioners, our mission is to bring back the bright smile of the people who come to see us. Restoring masticatory function is one thing but one should always remember that the esthetics should always come first in any kind of restorative procedures. When treating complex rehabilitation cases, treatment planning is probably the most important step before you start any dental procedures. Obviously, esthetics should be the ultimate goal of the treatment and one should approach a case step by step to achieve an optimal result. For the past few years, "digital smile design" has been introduced in the field of dentistry. It can be applied by using various methods and tools. In this article, a very basic form of 2-dimensional digital smile designing was utilized to treat a complete mouth rehabilitation case. We will discuss how the DSD concept can be applied to your daily practice with a simple photograph and photoshop.

Study on the Textile Design using Buttons on Western clothing in the 18th·19th Centuries (18·19세기 서양 복식의 단추를 활용한 텍스타일 디자인 연구)

  • Lee, Eui-Jung;Kang, Kyung-Ae
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.24 no.2
    • /
    • pp.97-115
    • /
    • 2022
  • The study aims to explore a new direction for research on buttons by understanding the functions and artistic features of buttons on Western clothing in the 18th and 19th centuries, and to use the findings to develop a textile design. In terms of the research method, the period was set in the 18th and 19th centuries, when decorative features and artistic values of buttons on Western clothing reached theirpeak, while theoretical analysis was made based on literature and previous research papers on Western clothing, websites of the Metropolitan Museum and French Museum of Decorative Arts and other website materials, as well as special exhibition materials of the National Museum of Modern and Contemporary Art. Textile designs were developed using computer programs, including Clip Studio Paint and Adobe Photoshop, by integrating the reinterpreted motif of buttons in the 18th and 19th centuries and the styles that prevailed at that time. The results are as follows. First, buttons on Western clothing had the following three functions: a practical function, a symbolic function representing the wearer's status, and a decorative function expressing individuality and beauty. Second, buttons in the 18th century were works of art made with various handicraft techniques and were an important medium that expressed the wearer's fashion sense. In addition, buttons in the 19th century were mass-produced as a result of industrialization and took a major step forward with the development of materials and dyeing. Buttons reflected themes of poetry, drama, biblical stories, music and art, lifestyle,, along with the political and social atmosphere that rapidly changed after the revolution and fashion trends. Third, the artistic features and shapes of buttons were reinterpreted to create a design motif, and the design was developed reflecting the characteristic elements of the rococo style of the 18th century and the art nouveau style of the 19th century that can conform to modern fashion, thereby rediscovering the artistic meaning and value implied in buttons. In the future, the research on creative buttons of 20th century artists is expected to be conducted from various perspectives.