• Title/Summary/Keyword: photoplethysmograpy(PPG)

Search Result 2, Processing Time 0.019 seconds

Assessment of stress in virtual reality environment using power spectral density ratio and second derivative of photoplethysmography (광 혈류 신호의 주파수 파워 특성과 이차 미분값을 이용한 가상환경의 스트레스 평가)

  • Y.H. Nam;Kim, H.T.;H.D. Ko;Park, K.S.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.169-172
    • /
    • 2001
  • There are many people who suffer from simulation sickness when immersing in virtual reality. In this study, we analyzed two photoplethysmogram(PPG) parameters - a second derivative parameter and power spectral density ratios - in order to relate PPG parameters with simulation sickness. 36 young, healthy subjects were participated in the experiment, and each subject was equipped with a PPG electrode during his or her immersion. Simulation sickness section was defined as a 7 - second section which starts from the point where a subject reported simulation sickness, and normal section as a same-length section where no physical stimuli was presented to him or her. We compared the PPG parameters of the simulation sickness sections with the normal sections, - d/a ratio is believed to have lower value during vasodilation and higher value during vasoconstriction, however, we could not find much difference in the parameter between normal and simulation sickness sections. We also compared 1 to 10Hz power spectral density ratios in normal sections with in simulation sickness section, and found that 6 density ratios among them have different value. Therefore, the density ratios might be utilized as parameters to detect simulation sickness of subjects.

  • PDF

A Study on Arterial Characterization by Photoplethysmography Analysis (용적맥파 해석에 의한 동맥 혈관 특성화 연구)

  • 한상휘;변미경;김정국;허웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.5
    • /
    • pp.65-70
    • /
    • 2004
  • In this paper, we present a new methodology to analyze the characteristic of artery by using 4 channels photoplethysmograpy. The proposed parameter is a time difference of pulse transit time(PTT) between Pulse waves at finger site and at toe site. To verify the usefulness of the developed system volume pulse waves on 4 sites were measured simultaneously for total 51 normal subjects (male 26 and female 25) aged from 9 to 83 years old. And then correlations between the analysis parameters and age were evaluated by using linear regression analysis method. As the result of experiments, the change of parameter was found according to ages. The result of regression analysis about relationships between the parameter and ages for n=51, the coefficient of correlation of non-normalized data has 0.79770 in left side and 0.80599 in right side and the coefficient of correlation of normalized data by height has 0.81345 in left side and 0.81605 in right side.