• Title/Summary/Keyword: photo sensor

Search Result 344, Processing Time 0.142 seconds

Structural and photoelectrical properties of copper phthalocyanine(CuPc) thin film on Si substrate by thermal evaporation (Si 기판위에 열증착법으로 제조한 copper phthalocyanine(CuPc) 박막의 구조 및 광전특성)

  • Lee, Hea-Yeon;Jeong, Jung-Hyun;Lee, Jong-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.407-413
    • /
    • 1997
  • The crystallized CuPc(copper phthalocyanine) film on a p-type <100> Si substrate is prepared at the substrate temperature of $300^{\circ}C$ by thermal evaporation. X -ray diffraction analysis showed the CuPc film to have a-axis oriented structure. For the measurement of photovoltaic characteristics of the CuPc/Si film and the Si substrate, a transverse current-voltage (I-V) curve is observed. In the dark, the Au/Si junction is shown to be ohmic contact. However, under illumination, a photovoltaic effect is not observed. The I-V curve in the dark indicates that the CuPc film on Si may form an ohmic contact. Since the CuPc film is a p-type semiconductor, the CuPc/p-Si junction has no barrier at the interface. Under illumination, the CuPc/Si junction shows a large photocurrent comparing with that of the wafer. The result indicates that the CuPc layer plays an important role in the photocarrier generation under red illumination (600 nm). The CuPc/Si film shows the photo voltaic characteristics with a short-circuit photocurrent ($J_{sc}$) of $4.29\;mA/cm^{2}$ and an open-circuit voltage ($V_{oc}$) of 12 mA.

  • PDF

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.

Preparation and Properties of the X-ray Storage Phosphors BaFBr1-xIx:Eu2+, Na+ (X-선 저장 BaFBr1-xIx:Eu2+, Na+ 형광체의 제조 및 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Chan-Jung;Kim, Wan;Kang, Hee-Dong;Kim, Do-Sung;Seo, Hyo-Jin;Doh, Sih-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2002
  • The forming conditions of X-ray storage phosrhors $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ have been investigated, and measured the PSL emission spectra and its intensity, fading characteristics and does dependence of the prepared phosphors. These characteristics were compared with those of commercial image plate (ST-III) obtained from Fuji Photo Film Co. The optimal preparing conditions of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ Phosphor were 0.5 mol% of $EuF_3$, 4.0 mol% of NaF and composition ratio x=0.3, and the sintering temperature were $950^{\circ}C$ in $H_2$ atmosphere. When the composition ratio x was equal to 0, the spectral range of the luminescence of $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ phosphor was $365{\sim}420\;nm$, and its maximum luminescence intensity appeared at 390 nm. When composition ratio x was not equal to 0, the wavelength ranges and peak of the spectra were shifted to the longer wavelength with the growth of composition ratio x. A good linearity was shown between the PSL intensity and X-ray irradiation dose. The phosphor sample with x=0.3 exhibited better fading characteristics than that of other $BaFBr_{1-x}I_x:Eu^{2+}$ phosphor samples, and the fading characteristics of the PSL intensity at room temperature were shown poorer with increasing $I^-$ ion concentration. The lattice constant of the phosphor becomes larger with increasing the $I^-$ ion concentration.

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.