• 제목/요약/키워드: phase-comparison

검색결과 1,888건 처리시간 0.031초

고온에서의 점증적 최대운동시 매실함유 음료 밀 생수섭취에 따른 심박수 및 혈중 젖산농도 변화의 비교 (Comparison of Heart Rate and Blood Lactate between Ingestion of Prunus mume Solution and Water during Graded Maximal Exercise in Hot Environment)

  • 김기진;배지현
    • 동아시아식생활학회지
    • /
    • 제9권3호
    • /
    • pp.356-362
    • /
    • 1999
  • Humans may lose considerable amounts of water and electrolytes from sweat during exercise in a hot climate. Optimal ingestion of fluid-replacement beverages may overcome an obstacle factor of exercise performance in the heat. This study was performed the comparison of heart rate and blood lactate between ingestion of Prunus mume solution and water solution during graded maximal exercise using bicycle ergometer in the heat(ambient temperature of 31-32$^{\circ}C$ and relative humidity of 50-55%). Ten healthy no-heat-acclimatized males participated in the study. Exercise duration until all-out of graded testing in the condition of Prunus mume solution ingestion(786.15$\pm$47.66s) was significantly higher(P<0.05) than the condition of water ingestion. Heart rate at 4 min during graded testing and recovery phase in the condition of Prunus mume solution ingestion was significantly lower(P<0.05) than the condition of water ingestion. Blood lactate concentration at 30min of recovery phase after graded maximal exercise in the condition of Prunus mume solution ingestion was significantly lower(P<0.05) than the condition of water ingestion. Recovery rate of blood lactate concentration at 15 min and 30 min of recovery phase after grated maximal exercise in the condition of Prunus mume solution ingestion was significantly lower(P<0.05) than the condition of water ingestion. Present results suggested that ingestion of Prunus mume solution showed the positive effects on the cardiorespiratory function and acid-base regulation as compared with ingestion of water during graded maximal exercise and recovery phase in hot environment.

  • PDF

경막외 마취제 투여 유무에 따른 분만 1기 산부의 분만 통증, 불안, 자궁경관 개대 정도 비교 (Comparison of Obstetric Pain, Anxiety, and Cervical Dilatation between Epidural Analgesia and No Analgesia group during Labor Stage I)

  • 한수정;김증임;김묘진
    • 여성건강간호학회지
    • /
    • 제18권2호
    • /
    • pp.126-134
    • /
    • 2012
  • Purpose: This research was done to compare obstetric pain, anxiety and cervical dilatation between an epidural analgesia group and a control group. Methods: Participants were assigned to the experimental or control group depending on their decisions for pain relief. Subjective / objective obstetric pain, anxiety level and cervical dilatation were measured and ANOVA was used for comparison of groups and paired t-test to make pre-post comparisons. Results: Homogeneity of pain, anxiety and cervical dilatation were assessed at the latent phase. Cervical dilatation was larger in the control group than the experimental group, at both the active and the transitional phase (F=22.9, p<.001; F=39.9, p<.001 respectively). The degree of pain and anxiety were not significantly different between the groups. Within the experimental group, subjective / objective pain and anxiety level were significantly lower post-analgesia compared to pre-analgesia in the active phase. All variables, except for sweating in the objective pain measurement, changed significantly at the transient phase. Conclusion: The results of this evidence-based research indicate that epidural analgesia while effective in relieving pain and anxiety may have an adverse effect on the cervix during labor stage I. Epidural analgesia should be used carefully during cervical dilatation in labor stage I.

블라인드 적응 등화를 위한 CMA와 MMA 알고리즘의 성능 비교 (The Performance Comparison of the CMA and MMA Algorithm for Blind Adaptive Equalization)

  • 임승각
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.153-158
    • /
    • 2012
  • 본 논문에서는 통신 채널에서 발생되는 찌그러짐과 잡음의 영향을 최소화하기 위하여 사용되는 적응 등화 알고리즘인 CMA 와 MMA 의 성능을 비교하였다. 다른 방식에비해 비교적 간단한 연산으로 고속 등화가 가능한 알고리즘인 CMA (Constant Modulus Algorithm)와 이의 오차 함수를 변형한 MMA (Multi-Modulus Algorithm)의 성능을 분석하여 점대점 또는 점대다점의 디지털 전송에서 적용 가능성을 확인하였다. CMA 알고리즘은 수신 신호의 진폭만을 보상하며 위상은 보상하지 못하므로 별도의 PLL을 사용하여야 하지만, MMA 알고리즘은 진폭과 위상을 동시에 보상할 수 있음을 컴퓨터 시뮬레이션을 통하여 확인하였으며 이의 성능 비교를 위해서 적응 등화기에 필수적인 수렴 특성과 잔류 isi양을 사용하였고, 그 결과 수렴 특성에서는 MMA 방식이, 진폭 보상을 나타내는 잔류 isi 양에서는 CMA 방식이 우월함을 알 수 있었다.

Split-bolus CT urography with synchronous nephrographic and excretory phase in dogs: comparison of image quality with three-phase CT urography and optimal allocation ratio of contrast medium

  • Je, Hyejin;Lee, Sang-Kwon;Jung, Jin-Woo;Jang, Youjung;Chhoey, Saran;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • 제21권4호
    • /
    • pp.55.1-55.11
    • /
    • 2020
  • Background: Computed tomography urography (CTU), based on the excretion of contrast medium after its injection, allows visualization of the renal parenchyma and the renal collecting system. Objectives: To determine the optimal contrast medium dose allocation ratio to apply in split-bolus CTU in dogs. Methods: This prospective, experimental, exploratory study used 8 beagles. In 3-phase CTU, unenhanced-, nephrographic-, and excretory-phase images were obtained with a single injection of 600 mg iodine/kg iohexol. In split-bolus CTU, two different contrast medium allocation ratios (30% and 70% for split CTU 1; 50% and 50% for split CTU 2) were used. Unenhanced phase image and a synchronous nephrographic-excretory phase image were acquired. Results: Although the attenuation of the renal parenchyma was significantly lower when using both split CTUs than the 3-phase CTU, based on qualitative evaluation, the visualization score of the renal parenchyma of split CTU 1 was as high as that of the 3-phase CTU, whereas the split CTU 2 score was significantly lower than those of the two others. Artifacts were not apparent, regardless of CTU protocol. The diameter and opacification of the ureter in both split CTUs were not significantly different from those using 3-phase CTU. Conclusions: Split-bolus CTU with a contrast medium allocation ratio of 30% and 70% is feasible for evaluating the urinary system and allows sufficient enhancement of the renal parenchyma and appropriate distention and opacification of the ureter, with similar image quality to 3-phase CTU in healthy dogs. Split-bolus CTU has the advantages of reducing radiation exposure and the number of CT images needed for interpretation.

Transmission Performance Comparison of Direction Detection-Based 100-Gb/s Modulation Formats for Metro Area Optical Networks

  • Chung, Hwan Seok;Chang, Sun Hyok;Lee, Jonghyun;Kim, Kwangjoon
    • ETRI Journal
    • /
    • 제34권6호
    • /
    • pp.800-806
    • /
    • 2012
  • Transmission performances of direct detection-based 100-Gb/s modulation formats are investigated and compared for metro area optical networks. The effects of optical signal-to-noise ratio sensitivity, chromatic dispersion, cross-channel nonlinearity, and transmission distance on the performance of differential 8-ary phase-shift keying (D8PSK), differential phase-shift keying plus three-level amplitude-shift keying (DPSK+3ASK), and dual-carrier differential quaternary phase-shift keying (DC-DQPSK) are evaluated. The performance of coherent dual-polarization quadrature phase-shift keying (DP-QPSK) with block phase estimation and coherent DP-QPSK with digital differential detection are also presented for reference. According to our analysis, all three direct detection modulation formats could transmit a 100-Gb/s signal over several hundred kilometers of a single-mode fiber link. The results also show that DC-DQPSK outperforms D8PSK and DPSK+3ASK, and the performance of DC-DQPSK is comparable to that of coherent DP-QPSK with digital differential detection. The maximum transmission distance of DC-DQPSK is over 1,000 km, which is enough distance for metro applications.

Investigation of Boiling Heat Transfer Characteristics of Two-Phase Closed Thermosyphons with Various Internal Grooves

  • Han, Ku-Il;Cho, Dong-Hyun;Park, Jong-Un
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1739-1745
    • /
    • 2003
  • The boiling heat transfer characteristics of two-phase closed thermosyphons with internal grooves are studied experimentally and a simple mathematical model is developed to predict the performance of such thermosyphons. The study focuses on the boiling heat transfer characteristics of a two-phase closed thermosyphons with copper tubes having 50, 60, 70, 80, 90 internal grooves. A two-phase closed thermosyphon with plain copper tube having the same inner and outer diameter as those of grooved tube is also tested for comparison. Methanol is used as working fluid. The effects of the number of grooves, the operating temperature, the heat flux are investigated experimentally. From these experimental results, a simple mathematical model is developed. In the present model, boiling of liquid pool in the evaporator is considered for the heat transfer mechanism of the thermosyphon. And also the effects of the number of grooves, the operating temperature, the heat flux are brought into consideration. A good agreement between the boiling heat transfer coefficient of the thermosyphon estimated from experimental results and the predictions from the present mathematical model is obtained. The experimental results show that the number of grooves and the amount of the working fluid are very important factors for the operation of thermosyphons. The two-phase closed thermosyphon with copper tubes having 60 internal grooves shows the best boiling heat transfer performance.

파킨슨씨 병 환자와 정상인의 입각기시간과 상비율의 비교 (Comparison of the Total Stance Time And the Phase Ratio in Parkinson's Disease Patients And Normal Subjects)

  • 김지원;엄광문
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.351-356
    • /
    • 2006
  • The purpose of this study is to investigate the gait characteristics in Parkinson's disease patients. Specifically, the total stance time and the ratio of each stance phase (heel strike, mid-stance, propulsion) are analyzed from the foot-pressure measurement system which requires low cost and small space compared to the conventional gait analysis system. The gait characteristics were analyzed in 23 Parkinson's disease patients (before and after L-dopa medication), 34 elderly (sixties) normal subjects and 21 young (twenties) normal subjects. Bradykinesia global score (self-developed score of slowness of body movement) of patients before medication was determined to see the relationship between the score and the gait characteristics. The total stance time was greater in the erde. of patients, elderly, youngs (p<0.05). The phase ratio of heel strike and propulsion was smaller and that of mid-stance was greater in the order of patients, elderly, youngs (p<0.05). However, there was no significant difference in the above gait characteristics of patients before and after medication. There was a tendency, though statistically non-significant, that the total stance time is longer and the propulsion phase ratio is shorter in patients with greater Bradikinesia global scale, and this tendency was relieved after medication.

직접 분사식 연료 분무에서의 기.액상 분리 계측에 관한 연구 (An Experimental Study on the Analysis of Liquid/Vapor Phase in GDI Spray)

  • 장석형;김정호;박경석;진성호;김경수
    • 한국분무공학회지
    • /
    • 제5권4호
    • /
    • pp.57-65
    • /
    • 2000
  • For this research an extension of the LIF technique that the LIEF(Laser Induced Exciplex Fluorescence) technique has been used LIEF technique is the unique method to allows the visualization of fuel vapor phase and liquid phase individually by capturing each signals of them. In this work performed that the basic procedure for advanced LIEF technique using TEA and benzene as dopants md high power KrF excimer laser to excite the dopants. Iso-octane is used as the fuel because it does not absorb light at the laser wavelength. The boiling point of benzene and TEA are $81^{\circ}C\;and89^{\circ}C$, respectively, in comparison to $99^{\circ}C$ for iso-octane. It is observed that the behavior and distribution of high pressed fuel injection from various test condition. The injection pressure is set as 3MPa. and 5MPa. And the ambient pressure of test chamber is atmospheric pressure and 1MPa, the ambient temperature of chamber is room temperature, $300^{\circ}C\;and\;500^{\circ}C$ to imitate the condition of GDI engine cylinder.

  • PDF

알카리 수전해 스택에서 수소기포의 2상유동 수치해석에 관한 연구 (A Study on Numerical Analysis Using the Two Phase Flow in Alkaline Water Electrolysis Stacks)

  • 한진목;배유근;서영진;김세웅;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권2호
    • /
    • pp.155-162
    • /
    • 2018
  • In this paper, the reliability of the numerical analysis using the two phase flow on the behavior of the hydrogen bubbles in the alkali electrolysis stacks was investigated by comparing the results obtained from numerical analysis and flow visualization experiments. As the results, through comparison with results gotten to visualization experiments, it is possible to approximate analysis for the flow of hydrogen bubbles in the stacks by numerical analysis using the two-phase flow. Also, the flow of hydrogen bubbles around the electrodes could be similarly analyzed by numerical analysis using the two-phase flow.

전자회절실험에 의한 알루미늄 합금 (Al-Cu-Mg)의 미세 S-상 석출입자에 대한 결정구조 연구 (A Study of the Crystal Structure of the Fine S-Phase Precipitate in Al-Cu-Mg Alloy by Electron Diffraction Experiments)

  • 김황수
    • Applied Microscopy
    • /
    • 제35권4호
    • /
    • pp.1-9
    • /
    • 2005
  • 이 논문에서 Al-Cu-Mg 합금의 미세 석출 입자의 S-상 ($Al_2CuMg$) 결정구조에 대해 전자회절실험에 의한 포괄적인 연구 결과가 보고 되어 있다. 이 실험에는 한 S-상 입자를 포함하는 최소 영역의 일정 zone축의 회절패턴(SAED) 관찰과 이에 대응되는 운동학적 이론을 기초로 한 패턴의 시물레이션과의 비교 분석, 그리고 관측된 회절 패턴 필름으로부터 각 Bragg회절 점의 강도의 정량적 데이터 추출과 운동학적 및 동역학적 회절 강도 계산과의 비교 검토의 과정을 포함하고 있다. 이러한 연구의 한 결과 S-상의 결정구조는 일찍이 X-ray 방법으로부터 얻은 PW 모델결정(Perlitz and Westgren, 1943)과 일치함을 보여주고 있고, HREM 방법에 의해 새로이 구한 RaVel (Radmilovic et al., 1999) 모델과는 전혀 맞지않음이 판명되었다.