• Title/Summary/Keyword: phase speed

Search Result 2,640, Processing Time 0.035 seconds

Kinematic Analysis of Women's 100-m Final during IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 100 m 여자 결승전의 운동학적 분석)

  • Ryu, Ji-Seon;Ryu, Jae-Kyun;Kim, Tae-Sam;Park, Young-Jin;Hwang, Won-Seob;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.521-528
    • /
    • 2011
  • The purpose of this study was to analyze the kinematic characteristics of the finalists in the women's 100 m event to provide important information to coaches and athletes. Three different biomechanics techniques were applied for analyzing sprinter motion: LAVEG, a panning technique, and 12 video cameras for 3 dimensional analysis of the 40 m - 70 m portion of the race. Carmelita Jeter(USA) performed the maximum speed of 10.54 m/s at the distance of 58.2 m. There was a tendency to show a better performance time with a high number of steps (p=.13) and shorter stride length (p=.14) among the 8 sprints. Furthermore, the stride frequency and the performance time were negatively correlated as a higher stride frequency had a positive impact on the performance time (p=.02). Based on 3 dimensional analysis, the 4 top ranked sprinters used the different strategies to maintain a high COM (Center of Mass) velocity during the mid portion of the race (40 m - 70 m). Carmelita Jeter(USA) showed more flexed knee and hip motion at heel contact (HC) to maintain a high COM velocity while S.A. Fraser-Pryce (JAM) showed more extended knee and hip motion at HC. On the other hands, Veronica Campbell-Brown (JAM) and Kelly-Ann Baptiste (TRI) showed a tendency to have high knee lifts during the swing phase to maintain the high COM velocity during the race. These biomechanical analyses of the women's 100 m final event in the 2011 WC, Daegu, will provide important scientific information to coaches and athletes for understanding the sprinting mechanism of today's top-class sprinters.

Quantitative Analysis of Cystic Fluid Components in Cysticercus cellulosae (유구낭미충(有鉤囊尾蟲) 낭액(囊液)의 아미노산(酸) 및 유리지방산(遊離脂肪酸)의 정량분석(定量分析))

  • Moon, Joon;Chung, Myung-Sook;Joo, Kyoung-Hwan;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.16 no.2
    • /
    • pp.141-153
    • /
    • 1991
  • Free amino acid(FAA), free fatty acid(FFA), and amino acid obtained by hydrolysis of protein components of cystic fluid(CF) of Cysticercus cellulosae in pig and man were analyzed. FFA was analyzed by gas chromatography using Varian model 2700, and flame ionization detector with 6 feet${\times}$1/4inch glass column. Flow rate of $N_2$ was 30 ml/min, $H_2$ was 30 ml/min, air was 350 ml/min respectively and chart speed was 1 cm/min. Amino acid was analyzed by high performance liquid chromatography using Waters model 441, and fluorescence detector at 338nm/425nm with column of amino acid analyzer. Buffer A of mobile phase was pH 3.05 and pH of buffer B was 9.6 respectively. The results obtained were as follows : Seven FFAs containing 12~18 carbons were detected : Saturated fatty acids were lauric acid ($C_{12}$), myristic acid($C_{14}$), palmitic acid($C_{16}$), Stearic acid($C_{18}$). Unsaturated fatty acids were oleic acid($C_{12}^{=1}$), linoleic acid($C_{12}^{=2}$), and one unidentified fatty acid was detected. Generally much more quantity of FFA was determined in CF obtained from pig than that from man. FFA of the largest quantity was palmitic acid; 0.078 mg/ml. Eighteen FAAs were detected and the largest quantity was alanine. Ouantity of alanine was 386 ug/ml in CF from pig 108 ug/ml in CF from man respectively. while histidine in CF from pig was 273 ug/ml, that from man was only 4.3 ug/ml. Eighteen amino acids were identified by hydrolysis of protein in CF from man. But, histidine was not identified in CF from pig. Amino from pig and ug/ml from man.

  • PDF

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

A Brake Pad Wear Compensation Method and Performance Evaluation for ElectroMechanical Brake (전기기계식 제동장치의 제동패드 마모보상방법 및 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Choon-Soo;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.581-588
    • /
    • 2020
  • This study examined a brake pad wear compensation method for an Electro-Mechanical Brake (EMB) using the braking test device. A three-phase Interior Permanent Magnet Synchronous Motor (IPMSM) was applied to drive the actuator of an EMB. Current control, speed control, and position control were used to control the clamping force of the EMB. The wear compensation method was performed using a software algorithm that updates the motor model equation by comparing the motor output torque current with a reference current. In addition, a simple first-order motor model equation was applied to estimate the output clamping force. The operation time to the maximum clamping force increased within 0.1 seconds compared to the brake pad in its initial condition. The experiment verified that the reference operating time was within 0.5 seconds, and the maximum value of the clamping force was satisfied under the wear condition. The wear compensation method based on the software algorithm in this paper can be performed in the pre-departure test of rolling stock.

A Study on Design of Reference Stations and Integrity Monitors for Maritime DGPS Recapitalization (해양용 DGPS 구조개선을 위한 RSIM 설계에 관한 연구)

  • Park, Sang-Hyun;Seo, Ki-Yeol;Cho, Deuk-Jae;Suh, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.691-697
    • /
    • 2009
  • Hardware dedicated off-the-shelf maritime differential GPS RSIM lacks the open architecture to meet all the minimum maritime user requirements and to include future GNSS improvements after recapitalization. This paper carries out a study to replace existing hardware dedicated differential GPS RSIM with software differential GPS RSIM in order to make up the weak point of hardware dedicated off-the-shelf maritime differential GPS RSIM. In this paper, the architecture of software RSIM is proposed for maritime DGPS recapitalization. And the feasibility analysis of the proposed software differential GPS RSIM is performed as the first phase to realize the proposed architecture. For the feasibility analysis, the prototype RF module and DSP module are implemented with properties as wide RF bandwidth, high sampling frequency, and high speed transmission interface. This paper shows that the proposed architecture has the possibility of real time operation of software RSIM functionality onto the PC-based platform through the analysis of computation time. Finally, this paper verifies that the L1/L2 dual frequency software differential RSIM designed according to the proposed method satisfies the performance specifications set out in RTCM paper 221-2006-SC104-STD.

A Study on the Development of SSB Modem (디지털 SSB 모뎀 개발에 관한 연구)

  • Jin, Heung-Du;Choi, Jo-Cheon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.693-697
    • /
    • 2007
  • The SSB modem performs the modulation process which converts the digital voltage level to the audible frequency band signal and the demodulation process which converts reversely the audible frequency signal to the digital voltage level. The modulator and the demodulator are implemented with a single DSP chip. Because of the SSB specific character, the distortion occurs when the frequency is changed. This distortion has no effect on voice communication, but it has an significant effect on data communication. In other words, it is impossible to send data stream with adjacent 2 periods. Therefore, in case of using 2-tone FSK, it is needed to send at least 3 periods to transmit 1 bit. Therefore we implemented the modem using modified phase-delay shift keying to transmit 1 tone signal for high speed transmission. In the 1200[bps] mode, it generates 0, $187{\mu}s$ delay time at 1.3kHz symbol frequency, and in the 2400[bps] mode, 0, $70{\mu}s$, $130{\mu}s$, $200{\mu}s$ delay time at 1.5kHz symbol frequency. Finally, in the maximum 3600[bps] mode, it generates 0, $100{\mu}s$, $160{\mu}s$, $250{\mu}s$ delay time at 2.0kHz symbol frequency. The measured results of the implemented SSB modem shows a good transfer functional characteristic by spectrum analyzer, almost same bandwidth in pass band and 20dB higher SNR comparing the German PACTOR and American CLOVER and in the experimental transmitting test, we verified the transmitted data is received correctly in platform.

  • PDF

Effect of Gas- and Liquid-injection Methods on Formation of Bubble and Liquid Slug at Merging Micro T-junction (마이크로 T자형 합류지점에서 기체 및 액체의 주입 방법이 기포 및 액체 슬러그 생성에 미치는 영향)

  • Lee, Jun Kyoung;Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.227-236
    • /
    • 2016
  • In the present experimental study, the effect of gas- and liquid-injected methods on the formation of bubble and liquid slug at the merging micro T-junction of a square microchannel with dimensions $600{\mu}m{\times}600{\mu}m$ was investigated. Nitrogen and water were used as test fluids. The superficial velocities of the liquid and gas were in the range of 0.05 - 1 m/s, and 0.1 - 1 m/s, respectively, where the Taylor flow was observed. The bubble length, liquid slug length, bubble velocity, and bubble generation frequency were measured by analyzing the images captured using a high-speed camera. Under similar inlet superficial velocity conditions, in the case of gas injection to the main channel at the merging T-junction (T_gas-liquid), the lengths of the bubble and liquid slug were longer, and the bubble generation frequency was lower than in the case of liquid injection to the main channel at the merging T-junction (T_liquid-gas). On the other hand, in both cases, the bubble velocity was almost the same. The previous correlation proposed using experimental data for T_liquid-gas had predicted the present experimental data of bubble length, bubble velocity, liquid slug length, and bubble generation frequency for T_gas-liquid to be ~24%, ~9%, ~39%, ~55%, respectively.

A Study on the Direct connection Service Effectiveness in Gyeongbu(KTX) (경부선(KTX) 직결운행 도입 효과에 관한 연구)

  • Kim, Ik-Hui;Kim, Yeong-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.5
    • /
    • pp.91-100
    • /
    • 2007
  • This study suggests direct connection service which has advantage of high-speed operation of KTX and access convenience of general train, and Pre-feasibility studies on the direct connection service. And analyze transportation demand change by the method as follows; It is to analyze the demand change of before and after KTX operation by previous transport data of Gyeongbu line, and calculate the coefficient of utilization using triggering demand by opening the 2nd phase of Gyeongbu line (Dongdaegu${\sim}$Busan). Through Pre-feasibility analysis, reduction $70{\sim}100$ minutes of train travel time and total revenue will increase about $100 thousand per day. Also, there will be environment-friendly effects of decreasing $CO_2$ emissions. But, Direct connection service need to highly cost ; Buying and Operation cost of KTX train. Therefore, we will be get more correct result of Pre-feasibility study on direct connection service, if there are concrete on buying the KTX action plans.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Kinematic Analysis of Acopian in Vault (도마종목 Kasamatsu계의 Akopian 기술동작 분석)

  • Lee, Soon-Ho;Park, Jong-Hoon;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.89-99
    • /
    • 2006
  • The study were to assess technical factors between the high score group and the low score group, from the subjects of 16 male national gymnasts, and to analyze the kinematical characteristic and main technical cause on technique of Akopian's 3D motion analysis of the male vaulting game in 2001 classification championship. The result of this study is this. There were not so much difference between the two groups in term; of the time of board contact, pre-flight, and total performance, but it takes shorter time when the players who are in the high point group take down the board, and they take long time for post-flight(p<.01). The high point group has a longer perpendicular distance in the moment of horse taking off, 0.05m on the average, than the low point group. The high point group shows 0.16m higher on the average than the other group in term; of the height of post-flight(p<.01). In the phase of board contact, the range of horizontal velocity at board take on were $7.66m/s{\sim}7.33m/s$, but there weren't significantly statistic differences between two groups. The hight score group were 0.68m/s faster than the low point group at the horizontal velocity at board take off event(<.05). About the average horizontal velocity of deceleration, AG1(-1.95m/s) reduces the speed more than AG2(-1.57m/s)(p<.05). And the hight score group were 0.37m/s faster than the low point group at the vertical velocity at horse take off event(<.05). When board taking off, the projectile angle of com were $38.7{\sim}37.8degree$ on the average. the comparative groups show almost same results. When horse taking off, the HPVy of the high point group were 37.6 degree which were a little higher than the low point group. The angular velocities of the players who takes on the horse with a right hand and then takes off with a left hand in the high point group were 14.97rad/sec, 10.82rad/sec in the low point group. However, the angular velocity of the players who takes on the horse with a left hand and then takes off on a right hand with the high point group were 14.97rad/sec, 15.56rad/sec in the low point group.