• Title/Summary/Keyword: phase insertion

Search Result 245, Processing Time 0.029 seconds

A Ku-Band 5-Bit Phase Shifter Using Compensation Resistors for Reducing the Insertion Loss Variation

  • Chang, Woo-Jin;Lee, Kyung-Ho
    • ETRI Journal
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • This paper describes the performance of a Ku-band 5-bit monolithic phase shifter with metal semiconductor field effect transistor (MESFET) switches and the implementation of a ceramic packaged phase shifter for phase array antennas. Using compensation resistors reduced the insertion loss variation of the phase shifter. Measurement of the 5-bit phase shifter with a monolithic microwave integrated circuit demonstrated a phase error of less than $7.5{\circ}$ root-mean-square (RMS) and an insertion loss variation of less than 0.9 dB RMS for 13 to 15 GHz. For all 32 states of the developed 5-bit phase shifter, the insertion losses were $8.2{\pm}1.4$dB, the input return losses were higher than 7.7 dB, and the output return losses were higher than 6.8 dB for 13 to 15 GHz. The chip size of the 5- bit monolithic phase shifter with a digital circuit for controlling all five bits was 2.35 mm ${\times}$1.65 mm. The packaged phase shifter demonstrated a phase error of less than $11.3{\circ}$ RMS, measured insertion losses of 12.2 ${\pm}$2.2 dB, and an insertion loss variation of 1.0 dB RMS for 13 to 15 GHz. For all 32 states, the input return losses were higher than 5.0 dB and the output return losses were higher than 6.2 dB for 13 to 15 GHz. The size of the packaged phase shifter was 7.20 mm${\times}$ 6.20 mm.

  • PDF

Reflection-Type 5-bit Digital Phase Shifter with Constant Insertion Loss (균일 삽입 손실 특성을 갖는 반사형의 5-비트 디지털 위상 변위기)

  • 고경석;최익권
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.582-589
    • /
    • 2002
  • This paper presents 12.2 GHz ~ 12.7 GHz frequency band reflection type 5-bit digital phase shifter with constant insertion loss property that was fabricated with relatively low cost's InGaAs HEMT for amplifier. The unavoidable large insertion loss difference between on and off states of HEMT, when it is designed by conventional design theory based on ideal switching device, is removed by transforming the HEMT impedances at on and off states to other proper values connecting a certain length transmission line to HEMT and then applying the conventional design theory. The fabricated 5-bit digital phase shifter shows very good insertion loss properties of less than 1.5 dB insertion loss difference and -4.5 dB ~ -6 dB insertion loss in 35 phase steps at 12.2 GHz ~ 12.7 GHz. These results verify the design method presented in this paper, which is useful to design phase shifter of constant insertion loss with non-ideal switching device.

Power spectrum density analysis for the influence of complete denture on the brain function of edentulous patients - pilot study

  • Perumal, Praveen;Chander, Gopi Naveen;Anitha, Kuttae Viswanathan;Reddy, Jetti Ramesh;Muthukumar, Balasubramanium
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.187-193
    • /
    • 2016
  • PURPOSE. This pilot study was to find the influence of complete denture on the brain activity and cognitive function of edentulous patients measured through Electroencephalogram (EEG) signals. MATERIALS AND METHODS. The study recruited 20 patients aged from 50 to 60 years requiring complete dentures with inclusion and exclusion criteria. The brain function and cognitive function were analyzed with a mental state questionnaire and a 15-minute analysis of power spectral density of EEG alpha waves. The analysis included edentulous phase and post denture insertion adaptive phase, each done before and after chewing. The results obtained were statistically evaluated. RESULTS. Power Spectral Density (PSD) values increased from edentulous phase to post denture insertion adaption phase. The data were grouped as edentulous phase before chewing (EEG p1-0.0064), edentulous phase after chewing (EEG p2-0.0073), post denture insertion adaptive phase before chewing (EEG p3-0.0077), and post denture insertion adaptive phase after chewing (EEG p4-0.0096). The acquired values were statistically analyzed using paired t-test, which showed statistically significant results (P<.05). CONCLUSION. This pilot study showed functional improvement in brain function of edentulous patients with complete dentures rehabilitation.

A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System (공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구)

  • Lee, Hee Won;Park, Il Seouk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.

Improvement of catheter-related outcomes after application of tunneled cuffed hemodialysis catheter insertion without fluoroscopy

  • Kang, Seok Hui;Do, Jun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.3
    • /
    • pp.186-193
    • /
    • 2020
  • Background: Non-tunneled catheters (NTCs) are used for hemodialysis (HD) in many centers in which fluoroscopy is not easily accessed despite high complication rates and conditions requiring long-term HD. Therefore, here we aimed to evaluate the superiority of catheter-related outcomes after the application of tunneled cuffed catheter (TCC) without fluoroscopy versus unconditioned NTC insertion. Methods: We divided the participants into two phases: those receiving NTCs between March 2010 and February 2011 (phase I), and those receiving TCCs or NTCs between March 2011 and February 2012 (phase II). Catheter survival, nurse satisfaction, and reasons for catheter removal were analyzed. Results: Two hundred and sixty patients in phase I and 300 patients in phase II were enrolled in this study. The success rate of TCC insertion was 99.2%. The catheter survival rate in phase I was 65.5% at 1 month, while that in phase II was 74.9% at 1 month (p=0.023). We compared catheter survival between TCCs and NTCs for all periods regardless of phase. The TCC survival rate was higher than the NTC survival rate (p<0.001). Catheter-associated problems led to catheter removal in 97 patients (26.6%) in phase I and 68 patients (18.5%) in phase II (p=0.009). Among 14 HD nurses, all reported being satisfied with manipulation during pre-/post-HD, manupulation during HD, and overall. Eleven HD nurses (78.6%) reported being satisfied with the workload. Conclusion: Compared with unconditional NTC insertion for HD, TCC insertion without fluoroscopy improved the overall catheter survival and nurse satisfaction rates.

Changes of Surface Electromyography on Frontalis Muscle during Electro-Acupuncture Stimulation of Abdomen or Legs - A Pilot Study for Clinical Approach to Autonomic Nervous System Changes - (복부 및 사지 부위의 전기침 자극이 전두근에서 측정한 SEMG 변화에 미치는 영향 - 자율신경계의 변화에 대한 임상적 접근을 위한 사전 연구 -)

  • Je, Jun-Tae;Choi, San-Ho;Shin, Sun-Ho;Lim, Jin-Young;Lee, Sang-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.14-25
    • /
    • 2012
  • Objectives : To observe physiological changes during clinical acupuncture treatment. Methods : We recruited 40 healthy volunteers who had experienced an acupuncture treatment at least once within the past three years. The experimental group was divided into four groups according to the needling site and frequency of electrical stimulation. Sites consisted of abdomen and legs. Frequencies consisted of 100 Hz and 2 Hz. The procedures of experimental treatment consisted of seven phases, Resting I phase (Resting I), Needle insertion phase (Insertion), Maintenance of needle insertion I phase (Maintain I), Electrical stimulation phase (ES), Maintenance of needle insertion II phase (Maintain II), Needle removal phase (Removal) and Resting II phase (Resting II). We measured the surface electromygraphy (SEMG) through an electrode on the frontalis muscle during all phases consecutively. Results : When SEMGs of all seven phases were analyzed, they significantly increased or decreased according to phases. SEMGs of Insertion, Maintain I, ES and Maintain II phase significantly increased more than RestingI in abdomen and legs groups. SEMGs of the abdomen group were measured as being $4.78{\pm}0.74{\mu}V$ on Resting I, $16.48{\pm}3.97{\mu}V$ on Insertion, $46.31{\pm}10.56{\mu}V$ on Maintain I, $45.88{\pm}9.72{\mu}V$ on ES, $45.56{\pm}9.69{\mu}V$ on Maintain II, $18.76{\pm}3.05{\mu}V$ on Removal, and $3.75{\pm}0.65{\mu}V$ on Resting II. SEMGs of the legs group were measured as being $3.34{\pm}0.35{\mu}V$ on Resting I, $12.11{\pm}1.76{\mu}V$ on Insertion, $36.74{\pm}6.99{\mu}V$ on Maintain I, $33.57{\pm}6.30{\mu}V$ on ES, $32.66{\pm}6.03{\mu}V$ on Maintain II, $14.08{\pm}2.15{\mu}V$ on Removal, and $2.88{\pm}0.32{\mu}V$ on Resting II. Conclusions : SEMG changed differently according to processes of acupuncture. Electrical stimulation showed different change of SEMG. Thus, acupuncture treatment may change the status of the autonomic nervous system.

Fabrication and Characterization of Lateral p-i-n photodiodes and design of stub mounted optically controlled phase shifter (수평형 p-i-n 광다이오드의 제작, 특성 측정 및 광제어 스터브 장착 위상기의 설계)

  • 한승엽;정상구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.89-96
    • /
    • 1995
  • Lateral p-i-n photodiodes have been fabricated, electrically tested, and incorporated into microwave control circuits such as an optically excited microwave atttenuator and reflection type phase shifter. Circuit design procedures for the loaded-line phase shifter with the optically controlled p-i-n photodiode are presented. The equal loss loading mode presented for the first time for the phase shifter circuits with lossy load allows an equal insertion loss of the phase shifter in both of its phase states. It is found that the insertion loss of the equal loss loading mode phase shifter constructed with the fabricated p-i-n photodiode load are about 3dB for 11.25$^{\circ}$ bit and 1dB for 5.625$^{\circ}$ bit for the frequency range of 2GHz to 11GHz.

  • PDF

Design and Implementation of a Ku-band Packaged 5-bit Phase Shiner (패키지된 KU-밴드용 5-비트 위상변위기 설계 및 제작)

  • 장우진;형창희;이희태;이경호;송민규
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.21-24
    • /
    • 2000
  • This paper introduces the design and implementation of a Ku-band 5-bit monolithic phase shifter with a ceramic package. The 5-bit phase shifter MMIC was designed and fabricated by using GaAs MESFET switches. The packaged phase shifter demonstrates a phase error less than 11.3 $^{\circ}$ RMS and an insertion loss variation less than 1.0㏈ RMS for 13∼15㎓. For all 32 states, an insertion loss is measured to be 12.2${\pm}$2.2㏈, an input return loss more than 5.0㏈, and an output return loss more than 6.2㏈ from 13㎓ to 15㎓. The chip size of the 5-bit phase shifter MMIC is 2.35${\times}$1.65mm$\^$2/ including digital control circuits. The size of the ceramic packaged phase shifter is 7.2${\times}$6.2mm$\^$2/.

  • PDF

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

2-6 GHz Digital Phase Shifter Module (2-6 GHz 디지털 위상변위기 모듈)

  • Jeong, Myeong-Deuk;So, Jun-Ho;U, Byeong-Il;Im, Jung-Su;Lee, Sang-Won;Park, Dong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.158-164
    • /
    • 2002
  • 2-6 GHz digital phase shifter module has been designed and fabricated. For the broadband operation and performance, MMIC phase shifter chip for phase shifter module was designed and fabricated by using the reflection-type circuits with Lange coupler. The fabricated phase shifter module shows 6.1$^{\circ}$RMS phase error, 13.5 dB maximum insertion loss, and 8 dB and 10 dB input and output return losses, respectively. Computer controlled measurement systems are realized in order to get the measured data of 32 phase states. The RMS insertion phase error and the average insertion loss deviation among 8${\times}$8 modules for the phased-array system are less than ${\pm}$0.5$^{\circ}$and ${\pm}$0.5 dB, respectively. The size of fabricated phase shifter module is 45 ${\times}$ 22.5 ${\times}$60㎣.