• 제목/요약/키워드: phase insertion

검색결과 245건 처리시간 0.023초

A Ku-Band 5-Bit Phase Shifter Using Compensation Resistors for Reducing the Insertion Loss Variation

  • Chang, Woo-Jin;Lee, Kyung-Ho
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.19-24
    • /
    • 2003
  • This paper describes the performance of a Ku-band 5-bit monolithic phase shifter with metal semiconductor field effect transistor (MESFET) switches and the implementation of a ceramic packaged phase shifter for phase array antennas. Using compensation resistors reduced the insertion loss variation of the phase shifter. Measurement of the 5-bit phase shifter with a monolithic microwave integrated circuit demonstrated a phase error of less than $7.5{\circ}$ root-mean-square (RMS) and an insertion loss variation of less than 0.9 dB RMS for 13 to 15 GHz. For all 32 states of the developed 5-bit phase shifter, the insertion losses were $8.2{\pm}1.4$dB, the input return losses were higher than 7.7 dB, and the output return losses were higher than 6.8 dB for 13 to 15 GHz. The chip size of the 5- bit monolithic phase shifter with a digital circuit for controlling all five bits was 2.35 mm ${\times}$1.65 mm. The packaged phase shifter demonstrated a phase error of less than $11.3{\circ}$ RMS, measured insertion losses of 12.2 ${\pm}$2.2 dB, and an insertion loss variation of 1.0 dB RMS for 13 to 15 GHz. For all 32 states, the input return losses were higher than 5.0 dB and the output return losses were higher than 6.2 dB for 13 to 15 GHz. The size of the packaged phase shifter was 7.20 mm${\times}$ 6.20 mm.

  • PDF

균일 삽입 손실 특성을 갖는 반사형의 5-비트 디지털 위상 변위기 (Reflection-Type 5-bit Digital Phase Shifter with Constant Insertion Loss)

  • 고경석;최익권
    • 한국전자파학회논문지
    • /
    • 제13권6호
    • /
    • pp.582-589
    • /
    • 2002
  • 본 논문에서는 스위칭 소자인 beam lead 형태의 pin 다이오드대신에 저가인 증폭기용 HEMT를 스위칭소자로 하여 12 GHz 대역에서 동작하는 일정 삽입 손실의 5-비트 디지털 반사형 위상 변위기를 설계 및 제작한다. 기존의 이상적인 스위칭소자에 기초한 이론에 의해 설계할 때 필연적인 HEMT소자의 on, off시 큰 삽입손실차는 특정한 길이의 전송선로를 우선 스위칭 소자에 연결하여 HEMT소자의 on, off시 임피던스를 변환한 후 기존의 방식대로 설계하는 방법에 의해 제거할 쑤 있었다. 제작된 위상변위기는 설계 주파수인 12.2GHz - 12.7GHz 대역내 32단계의 스위칭 상태에서 삽입손실이 -4.5dB에서 -6dB 범위에 있으며 특히 전 단계에서 삽입 손실의 변화량이 1.5 dB 이내로 양호한 특성을 가져 본 논문에서 처음 시도한 임피던스 변환용 전송선에 의한 삽입 손실차 제거방법의 타당성을 확인할 수 있었다.

Power spectrum density analysis for the influence of complete denture on the brain function of edentulous patients - pilot study

  • Perumal, Praveen;Chander, Gopi Naveen;Anitha, Kuttae Viswanathan;Reddy, Jetti Ramesh;Muthukumar, Balasubramanium
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.187-193
    • /
    • 2016
  • PURPOSE. This pilot study was to find the influence of complete denture on the brain activity and cognitive function of edentulous patients measured through Electroencephalogram (EEG) signals. MATERIALS AND METHODS. The study recruited 20 patients aged from 50 to 60 years requiring complete dentures with inclusion and exclusion criteria. The brain function and cognitive function were analyzed with a mental state questionnaire and a 15-minute analysis of power spectral density of EEG alpha waves. The analysis included edentulous phase and post denture insertion adaptive phase, each done before and after chewing. The results obtained were statistically evaluated. RESULTS. Power Spectral Density (PSD) values increased from edentulous phase to post denture insertion adaption phase. The data were grouped as edentulous phase before chewing (EEG p1-0.0064), edentulous phase after chewing (EEG p2-0.0073), post denture insertion adaptive phase before chewing (EEG p3-0.0077), and post denture insertion adaptive phase after chewing (EEG p4-0.0096). The acquired values were statistically analyzed using paired t-test, which showed statistically significant results (P<.05). CONCLUSION. This pilot study showed functional improvement in brain function of edentulous patients with complete dentures rehabilitation.

공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구 (A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System)

  • 이희원;박일석
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.

Improvement of catheter-related outcomes after application of tunneled cuffed hemodialysis catheter insertion without fluoroscopy

  • Kang, Seok Hui;Do, Jun Young
    • Journal of Yeungnam Medical Science
    • /
    • 제37권3호
    • /
    • pp.186-193
    • /
    • 2020
  • Background: Non-tunneled catheters (NTCs) are used for hemodialysis (HD) in many centers in which fluoroscopy is not easily accessed despite high complication rates and conditions requiring long-term HD. Therefore, here we aimed to evaluate the superiority of catheter-related outcomes after the application of tunneled cuffed catheter (TCC) without fluoroscopy versus unconditioned NTC insertion. Methods: We divided the participants into two phases: those receiving NTCs between March 2010 and February 2011 (phase I), and those receiving TCCs or NTCs between March 2011 and February 2012 (phase II). Catheter survival, nurse satisfaction, and reasons for catheter removal were analyzed. Results: Two hundred and sixty patients in phase I and 300 patients in phase II were enrolled in this study. The success rate of TCC insertion was 99.2%. The catheter survival rate in phase I was 65.5% at 1 month, while that in phase II was 74.9% at 1 month (p=0.023). We compared catheter survival between TCCs and NTCs for all periods regardless of phase. The TCC survival rate was higher than the NTC survival rate (p<0.001). Catheter-associated problems led to catheter removal in 97 patients (26.6%) in phase I and 68 patients (18.5%) in phase II (p=0.009). Among 14 HD nurses, all reported being satisfied with manipulation during pre-/post-HD, manupulation during HD, and overall. Eleven HD nurses (78.6%) reported being satisfied with the workload. Conclusion: Compared with unconditional NTC insertion for HD, TCC insertion without fluoroscopy improved the overall catheter survival and nurse satisfaction rates.

복부 및 사지 부위의 전기침 자극이 전두근에서 측정한 SEMG 변화에 미치는 영향 - 자율신경계의 변화에 대한 임상적 접근을 위한 사전 연구 - (Changes of Surface Electromyography on Frontalis Muscle during Electro-Acupuncture Stimulation of Abdomen or Legs - A Pilot Study for Clinical Approach to Autonomic Nervous System Changes -)

  • 제준태;최산호;신선호;임진영;이상관
    • 대한한방내과학회지
    • /
    • 제33권1호
    • /
    • pp.14-25
    • /
    • 2012
  • Objectives : To observe physiological changes during clinical acupuncture treatment. Methods : We recruited 40 healthy volunteers who had experienced an acupuncture treatment at least once within the past three years. The experimental group was divided into four groups according to the needling site and frequency of electrical stimulation. Sites consisted of abdomen and legs. Frequencies consisted of 100 Hz and 2 Hz. The procedures of experimental treatment consisted of seven phases, Resting I phase (Resting I), Needle insertion phase (Insertion), Maintenance of needle insertion I phase (Maintain I), Electrical stimulation phase (ES), Maintenance of needle insertion II phase (Maintain II), Needle removal phase (Removal) and Resting II phase (Resting II). We measured the surface electromygraphy (SEMG) through an electrode on the frontalis muscle during all phases consecutively. Results : When SEMGs of all seven phases were analyzed, they significantly increased or decreased according to phases. SEMGs of Insertion, Maintain I, ES and Maintain II phase significantly increased more than RestingI in abdomen and legs groups. SEMGs of the abdomen group were measured as being $4.78{\pm}0.74{\mu}V$ on Resting I, $16.48{\pm}3.97{\mu}V$ on Insertion, $46.31{\pm}10.56{\mu}V$ on Maintain I, $45.88{\pm}9.72{\mu}V$ on ES, $45.56{\pm}9.69{\mu}V$ on Maintain II, $18.76{\pm}3.05{\mu}V$ on Removal, and $3.75{\pm}0.65{\mu}V$ on Resting II. SEMGs of the legs group were measured as being $3.34{\pm}0.35{\mu}V$ on Resting I, $12.11{\pm}1.76{\mu}V$ on Insertion, $36.74{\pm}6.99{\mu}V$ on Maintain I, $33.57{\pm}6.30{\mu}V$ on ES, $32.66{\pm}6.03{\mu}V$ on Maintain II, $14.08{\pm}2.15{\mu}V$ on Removal, and $2.88{\pm}0.32{\mu}V$ on Resting II. Conclusions : SEMG changed differently according to processes of acupuncture. Electrical stimulation showed different change of SEMG. Thus, acupuncture treatment may change the status of the autonomic nervous system.

수평형 p-i-n 광다이오드의 제작, 특성 측정 및 광제어 스터브 장착 위상기의 설계 (Fabrication and Characterization of Lateral p-i-n photodiodes and design of stub mounted optically controlled phase shifter)

  • 한승엽;정상구
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.89-96
    • /
    • 1995
  • Lateral p-i-n photodiodes have been fabricated, electrically tested, and incorporated into microwave control circuits such as an optically excited microwave atttenuator and reflection type phase shifter. Circuit design procedures for the loaded-line phase shifter with the optically controlled p-i-n photodiode are presented. The equal loss loading mode presented for the first time for the phase shifter circuits with lossy load allows an equal insertion loss of the phase shifter in both of its phase states. It is found that the insertion loss of the equal loss loading mode phase shifter constructed with the fabricated p-i-n photodiode load are about 3dB for 11.25$^{\circ}$ bit and 1dB for 5.625$^{\circ}$ bit for the frequency range of 2GHz to 11GHz.

  • PDF

패키지된 KU-밴드용 5-비트 위상변위기 설계 및 제작 (Design and Implementation of a Ku-band Packaged 5-bit Phase Shiner)

  • 장우진;형창희;이희태;이경호;송민규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.21-24
    • /
    • 2000
  • This paper introduces the design and implementation of a Ku-band 5-bit monolithic phase shifter with a ceramic package. The 5-bit phase shifter MMIC was designed and fabricated by using GaAs MESFET switches. The packaged phase shifter demonstrates a phase error less than 11.3 $^{\circ}$ RMS and an insertion loss variation less than 1.0㏈ RMS for 13∼15㎓. For all 32 states, an insertion loss is measured to be 12.2${\pm}$2.2㏈, an input return loss more than 5.0㏈, and an output return loss more than 6.2㏈ from 13㎓ to 15㎓. The chip size of the 5-bit phase shifter MMIC is 2.35${\times}$1.65mm$\^$2/ including digital control circuits. The size of the ceramic packaged phase shifter is 7.2${\times}$6.2mm$\^$2/.

  • PDF

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

2-6 GHz 디지털 위상변위기 모듈 (2-6 GHz Digital Phase Shifter Module)

  • 정명득;소준호;우병일;임중수;이상원;박동철
    • 대한전자공학회논문지TC
    • /
    • 제39권3호
    • /
    • pp.158-164
    • /
    • 2002
  • 2-6 GHz 디지털 위상변위기 모듈을 설계, 제작하였다. 위상변위기 모듈에 사용된 MMIC 칩은 광대역을 구현하기 위해 Lange 커플러로 구성된 반사형 회로를 이용하여 설계 및 제작하였다. 위상변위기 모듈은 6.1°RMS 위상오차, 13.5 dB 최대 삽입손실과 각각, 8 dB와 10 dB의 입·출력 반사손실 특성을 갖는다. 32개의 위상 상태를 측정하기 위해서 컴퓨터를 사용하여 측정을 자동화 시켰다. 8×8 위상배열용 모듈들간의 RMS 삽입 위상오차는 최대 ±0.5°이내이고, 모듈들간의 평균 삽입손실 편차는 최대 ±0.5 dB를 넘지 않았다. 제작된 위상변위기 모듈의 크기는 45 × 22.5 × 60 ㎣. 이다.