• 제목/요약/키워드: phase control method

검색결과 2,516건 처리시간 0.03초

Current Sharing Method Based on Optimal Phase Shift Control for Interleaved Three-Phase Half Bridge LLC Converter with Floating Y-Connection

  • Shi, Lin;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.934-943
    • /
    • 2019
  • A current balance problem exists in multi-phase LLC converters due to the resonant parameter tolerance. This paper presents a current balancing method for interleaved three-phase half bridge LLC converters. This method regulates the phase shift angle of the driving signals between the three phases based on a converter with a floating Y-connection. The floating midpoint voltage has different influences on each phase current and makes the three-phase current balance performance better than midpoint non-floating systems. Phase shift control between modules can further regulate the midpoint voltage. Then three phase current sharing is realized without adding extra components. The current distributions in a midpoint non-floating system and a midpoint floating system are compared. Then the principle and implementation of the proposed control strategy are analyzed in detail. A 3kW prototype is built to verify the validity and feasibility of the proposed method.

Performance Evaluation of the Field-Oriented Control of Star-Connected 3-Phase Induction Motor Drives under Stator Winding Open-Circuit Faults

  • Jannati, Mohammad;Idris, Nik Rumzi Nik;Aziz, Mohd Junaidi Abdul
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.982-993
    • /
    • 2016
  • A method for the fault-tolerant vector control of star-connected 3-phase Induction Motor (IM) drive systems based on Field-Oriented Control (FOC) is proposed in this paper. This method enables the control of a 3-phase IM in the presence of an open-phase failure in one of its phases without the need for control structure changes to the conventional FOC algorithm. The proposed drive system significantly reduces the speed and torque pulsations caused by an open-phase fault in the stator windings. The performance of the proposed method was verified using MATLAB (M-File) simulation as well experimental tests on a 1.5kW 3-phase IM drive system. This paper experimentally compares the operation of the proposed fault-tolerant vector controller and a conventional vector controller during open-phase fault.

2상 유도전동기용 벡터제어 인버터를 위한 전류측정 오차 보상 방법 (Compensation Method of Current Measurement Error for Vector-Controlled Inverter of 2-Phase Induction Motor)

  • 이호준;윤덕용
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1204-1210
    • /
    • 2016
  • The phase currents must be accurately measured to achieve the instantaneous torque control of AC motors. In general, those are measured using the current sensors. However, the measured current signals can include the offset errors and scaling errors by several components such as current sensors, analog amplifiers, noise filter circuits, and analog-to-digital converters. Therefore, the torque-controlled performance can be deteriorated by the current measurement errors. In this paper we have analyzed the influence caused by vector control of 2-phase induction motor when two errors are included in measured phase currents. Based on analyzed results, the compensation method is proposed without additional hardware. The proposed compensation method was applied vector-controlled inverter for 2-phase induction motor of 360[W] class and verified through computer simulations and experiments.

인버어터구동 이상서어보 전동기의 마이크로프로세서에 위한 입상제어 (The Phase Contol Method of 2-Phase Servomotor Driven with Microprocessor-based Inverter)

  • 원종수;장도현
    • 대한전기학회논문지
    • /
    • 제36권2호
    • /
    • pp.80-87
    • /
    • 1987
  • This paper describes a new approach to control the two-phase servomotor driven with microprocessor based inverter. Conventional 6-step driving system has some shortcomings such as vibration and loss caused by the harmonic voltage. An attempt has been made to eliminate the harmonic content of output waveform by PWM technique and to simplify the control system by phase control method. In realizing the phase control by PWM technique proposed by this paper, control circuit and algorithm has been suggested. The proposed method has been applied to the speed control system with PI controller to confirm the adaptation of the servo system and experimental results has been compared with the computer simulation.

위상 조절방법에 의한 유연 회전체의 능동제어에 관한 연구 (A study on the Active Control for Flexible Rotors Using Phase Control Method)

  • 이원창;김성원;김재실;최헌오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.280-283
    • /
    • 2005
  • This study performed by a previous research for the applying expert system to active vibration control algorithm. In order to increase productivity and efficiency, high-speed rotating machines become popular these days. They are likely to vibrate and cause machine failure even though they have small unbalance. Therefore, a high-speed rotating machine needs a balancing technique. ISO 11342 classifies flexible rotors in accordance with their balancing requirements and establishes methods of assessment of residual unbalance. But, even if they finished balancing work, they have harmful effect vibration under the high-speed rotating environment. This vibration effect is very small, but it must be removed for the improvement of the rotor's spin accuracy. This paper introduces a new active control method that remove the exciting force by a phase control. For this method, the high-speed rotating rotor was reconstructed by a flexible rotor model. The forces which excite the rotating system suppose cyclic forces, we obtain the responses by numerical method. And then through the pattern analysis about the vibraton responses, the controler generate the control force with the reverse phase and similar magnitude. This paper suggest an phase control method and shows how to improve the rotating vibration accuracy of the flexible rotor dynamics system using phase control method.

  • PDF

원칩 마이컴을 이용한 단상유도전동기의 주권선 제어에 관한 연구 (A Study on the Main Winding Control of Single Phase Induction Motor using One-Chip Micom)

  • 박수강;백형래
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권1호
    • /
    • pp.70-76
    • /
    • 2000
  • This paper describes a one-chip micom controller and phase angle control method for self-starting and energy saving of single-phase induction motor. The proposed method is based on the optimal efficiency control which is running by variable phase angle of main winding current such as to maintain the maximum efficiency characteristics of the motor, in voltage control with TRIAC. Experiments are focused on a capacitor starting single-phase induction motor. The optimal energy saving by variable phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

A New Three-Phase Current Modulation Method to Suppress the Commutation Torque Ripple of Brushless DC Motor

  • Wang, Zhiqiang;Yin, Shuai;Ma, Tiehua
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1925-1933
    • /
    • 2017
  • The brushless DC motor's commutation torque ripple is caused by inconsistency in the rate of phase current change. Thus, a method that considers armature resistance is proposed to modulate phase current. The three-phase control strategy, which involves the "open-phase conduction, off-phase pulse width modulation, and maintained non-commutation phase" technique, is applied during commutation at full-speed segments of the motor. Changes in each phase current are analyzed theoretically by establishing mathematical model based on phase current to determine the relative difference among shutdown phase, duty, and motor operating parameters. The turn-on and turn-off phase current change rates are made to be consistent to ensure less non-commutation phase current ripple, then the torque ripple is inhibited. The simulation results show that the phase commutation current and torque ripple coefficient of the proposed method are reduced from 56.9% and 55.5% to 6.8% and 6.1%, respectively. In the experiment system, the pulsation coefficient of the motor phase current is reduced from 40.0% to 16.7% at low speed and 50.0% to 18.8% at high speed. The simulation and experimental results show that the proposed control method significantly inhibits commutation current and torque in the full section.

전원전압과 DC-link 전압 추정을 통한 3상 컨버터 센서리스 제어 (Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage)

  • 추흥석;박성준;김광태;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1233-1235
    • /
    • 2000
  • A new control method of three phase converter without measuring input phase-voltage and DC-link voltage is proposed. Input phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In addition, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어 (Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage)

  • 추흥석;천창근;안진우;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.227-230
    • /
    • 2001
  • A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

단상 PWM 컨버터에 적용한 공간 벡터 PWM (Adaptation of Space Vector Modulation to Single-Phase High Power PWM Converters)

  • 이희면;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.442-443
    • /
    • 2011
  • In this paper, a voltage control method based on DQ transformation and Space Vector Pulse Width Modulation (SVPWM) for a single phase three-level converter is proposed. This control method is designed to use DC values instead of using instantaneous values of current which are usually used in single-phase application, so that it results in a fast and robust voltage control response. Simulation results demonstrate the validity of the control strategies.

  • PDF