• 제목/요약/키워드: phase contrast image

검색결과 127건 처리시간 0.022초

Phase Contrast Projection Display Using Photopolymer

  • Piao, Mei-Lan;Kim, Nam;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.319-325
    • /
    • 2008
  • We propose a phase contrast filter using photopolymer, for the phase contrast projection display. The photopolymer has high photosensitivity such that its optically induced refractive index change has a linear dependency on the illuminating light intensity. We implemented a phase contrast projection display using photopolymer as a phase contrast filter. By controlling the refractive index change of the photopolymer, we successfully convert an input phase image into a high contrast intensity image. We also investigated the effect of the photopolymer illumination condition on the quality of the displayed intensity image. As a projector, we achieved 82% phase to intensity conversion efficiency, which implies that the proposed method can potentially have much higher light efficiency than conventional projection display.

Phase Dependent Image Contrast Enhancement in MRI

  • Y.M Ro;C. W. Mun;I. K. Hong
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.165-172
    • /
    • 1999
  • 본 연구에서는 MRI 영상에서 위상을 조절하여 영상 대조를 증가 시키는 방법을 제안 하였다 영상하고자 하는 물체 자체가 갖는 위상에 따라 영상의 대조가 변하기 때문에 본 방법은 자화율 영상이나 유속 영상에 유용하게 쓰일 수가 있다. 본 논문에서는 위상 분포에 따른 영상의 대조를 증가 시키기 위하여 RF 펄스를 복셀 내에서 위상을 갖도록 디자인 하였다. 따라서 복셀에서의 신호의 크기는 물체자체의 위상과 RF 펄스에의하여 가해준 위상이 결합에 의하여 결정된다. 외부위상 변화에 따른 신호의 변화를 분석하였고 그때 디자인된 RF 펄스를 이용하여 자화율만의 영상과 유속만의 영상을 얻었다. 컴퓨터 시뮬레이션의 결과는 제안된 알고리즘이 복셀내에 위상을 갖는 물체의 영상에 유용하고 그런 물체만을 영상하는데 유용함을 보였다.

  • PDF

선적분에 의한 위상차 영상의 줄무늬 아티팩트 감소를 위한 기계학습법에 대한 평가 (Evaluation of Machine Learning Methods to Reduce Stripe Artifacts in the Phase Contrast Image due to Line-Integration Process)

  • 김명근;오오성;이세호;이승욱
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.937-946
    • /
    • 2020
  • 격자간섭계는 한 위상 물체에 의한 파두의 굴절변화로 인해 그 물체에 대한 미분 위상 영상을 제공하며, 이 미분 위상 영상은 위상 영상으로 전환되어야 할 필요가 있다. 미분 위상차 영상으로부터 위상차 영상을 얻기 위한 선적분 과정은 노이즈를 축적하고 줄무늬 아티팩트를 생성한다. 줄무늬 아티팩트는 선적분이 수행된 위상차 영상에서 적분 방향으로 노이즈와 왜곡이 증가한다. 이 연구에서는 이러한 아티팩트를 줄이기 위해 몇 가지 기계 학습 방법들을 구성하고 비교하였다. 기계 학습 방법들은 상호비교를 위하여 시뮬레이션 된 수치 팬텀과 엑스선 및 중성자 격자 간섭계로부터 얻어진 실험 데이터에 적용되었다. 그 결과 웨이블릿 전처리와 기계 학습 방법(WCNN)의 조합이 가장 효과적인 것으로 나타났다.

Split-bolus CT urography with synchronous nephrographic and excretory phase in dogs: comparison of image quality with three-phase CT urography and optimal allocation ratio of contrast medium

  • Je, Hyejin;Lee, Sang-Kwon;Jung, Jin-Woo;Jang, Youjung;Chhoey, Saran;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • 제21권4호
    • /
    • pp.55.1-55.11
    • /
    • 2020
  • Background: Computed tomography urography (CTU), based on the excretion of contrast medium after its injection, allows visualization of the renal parenchyma and the renal collecting system. Objectives: To determine the optimal contrast medium dose allocation ratio to apply in split-bolus CTU in dogs. Methods: This prospective, experimental, exploratory study used 8 beagles. In 3-phase CTU, unenhanced-, nephrographic-, and excretory-phase images were obtained with a single injection of 600 mg iodine/kg iohexol. In split-bolus CTU, two different contrast medium allocation ratios (30% and 70% for split CTU 1; 50% and 50% for split CTU 2) were used. Unenhanced phase image and a synchronous nephrographic-excretory phase image were acquired. Results: Although the attenuation of the renal parenchyma was significantly lower when using both split CTUs than the 3-phase CTU, based on qualitative evaluation, the visualization score of the renal parenchyma of split CTU 1 was as high as that of the 3-phase CTU, whereas the split CTU 2 score was significantly lower than those of the two others. Artifacts were not apparent, regardless of CTU protocol. The diameter and opacification of the ureter in both split CTUs were not significantly different from those using 3-phase CTU. Conclusions: Split-bolus CTU with a contrast medium allocation ratio of 30% and 70% is feasible for evaluating the urinary system and allows sufficient enhancement of the renal parenchyma and appropriate distention and opacification of the ureter, with similar image quality to 3-phase CTU in healthy dogs. Split-bolus CTU has the advantages of reducing radiation exposure and the number of CT images needed for interpretation.

위상차 현미경 영상 내 푸리에 묘사자를 이용한 암세포 형태별 분류 (Classification of Tumor cells in Phase-contrast Microscopy Image using Fourier Descriptor)

  • 강미선;이정엄;김혜련;김명희
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권4호
    • /
    • pp.169-176
    • /
    • 2012
  • Tumor cell morphology is closely related to its migratory behaviors. An active tumor cell has a highly irregular shape, whereas a spherical cell is inactive. Thus, quantitative analysis of cell features is crucial to determine tumor malignancy or to test the efficacy of anticancer treatment. We use 3D time-lapse phase-contrast microscopy to analyze single cell morphology because it enables to observe long-term activity of living cells without photobleaching and phototoxicity, which is common in other fluorescence-labeled microscopy. Despite this advantage, there are image-level drawbacks to phase-contrast microscopy, such as local light effect and contrast interference ring. Therefore, we first corrected for non-uniform illumination artifacts and then we use intensity distribution information to detect cell boundary. In phase contrast microscopy image, cell is normally appeared as dark region surrounded by bright halo ring. Due to halo artifact is minimal around the cell body and has non-symmetric diffusion pattern, we calculate cross sectional plane which intersects center of each cell and orthogonal to first principal axis. Then, we extract dark cell region by analyzing intensity profile curve considering local bright peak as halo area. Finally, we calculated the Fourier descriptor that morphological characteristics of cell to classify tumor cells into active and inactive groups. We validated classification accuracy by comparing our findings with manually obtained results.

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.

축 방향 공간주파수 대역의 확장을 통한 고체 내부영상 개선 (The Enhancement of Inner-solid Image by the Bandwidth Increment of Vertically Spatial Frequency)

  • 구길모;김상백;김현;전계석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.176-180
    • /
    • 2001
  • In this paper, we have studies the images have been reconstructed by using combination of images which has been acquired by the variation of operating frequency. When inner images has been reconstructed, inner image has been superposition by surface state effect. In this case, image enhancement the phase object and enhance the contrast of inner image. In the result of the specimen for the round defect with 2mm diameter, for the types of the depth are 1.5mm, 2mm, 2.5mm, and 3mm, it has been show that the shape of defect has better than before this processing and phase contrast grow large twice. And we have constructed the acoustic microscope by using quadrature detector that is able simultaneously to acquired the amplitude and phase of the reflected signal. Father more we have studied the reconstruction method of the amplitude and phase images and the enhancement method of the defect images' contrast.

  • PDF

Numerical Modeling and Experiment for Single Grid-Based Phase-Contrast X-Ray Imaging

  • Lim, Hyunwoo;Lee, Hunwoo;Cho, Hyosung;Seo, Changwoo;Lee, Sooyeul;Chae, Byunggyu
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.83-91
    • /
    • 2017
  • In this work, we investigated the recently proposed phase-contrast x-ray imaging (PCXI) technique, the so-called single grid-based PCXI, which has great simplicity and minimal requirements on the setup alignment. It allows for imaging of smaller features and variations in the examined sample than conventional attenuation-based x-ray imaging with lower x-ray dose. We performed a systematic simulation using a simulation platform developed by us to investigate the image characteristics. We also performed a preliminary PCXI experiment using an established a table-top setup to demonstrate the performance of the simulation platform. The system consists of an x-ray tube ($50kV_p$, 5 mAs), a focused-linear grid (200-lines/inch), and a flat-panel detector ($48-{\mu}m$ pixel size). According to our results, the simulated contrast of phase images was much enhanced, compared to that of the absorption images. The scattering length scale estimated for a given simulation condition was about 117 nm. It was very similar, at least qualitatively, to the experimental contrast, which demonstrates the performance of the simulation platform. We also found that the level of the phase gradient of oriented structures strongly depended on the orientation of the structure relative to that of linear grids.

DLC코팅 마모면에 대한 원자력 현미경을 이용한 고찰 (An Investigation of Worn DLC Coatings Using Atomic Force Microscopy)

  • 안효석;조경만
    • Tribology and Lubricants
    • /
    • 제18권2호
    • /
    • pp.138-143
    • /
    • 2002
  • Abstract - Tribofilms formed on won surface protect the DLC coating surface and decrease the fiction coefficient. However it is very difficult to evaluate their micromechanical properties due to their small thickness, inhomogeneity and discontinuity. The phase contrast images in tapping mode atomic farce microscopy allow an estimation of inhomogeneity in micromechanical properties of the sample surface. The purpose of this investigation is to demonstrate how the phase contrast images contribute to the characterization of thin tribofilms.

DLC 코팅 마모면에 대한 원자력 현미경을 이용한 고찰 (An investigation of worn DLC coatings using atomic force microscopy)

  • 조경만;안효석
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.299-304
    • /
    • 2001
  • Tribofilms formed on worn surface protect the DLC coating surface and decrease the friction coefficient. However it is very difficult to evaluate their micromechanical properties due to their small thickness, inhomogeneity and discontinuity. The phase contrast images in tapping mode atomic force microscopy allow an estimation of inhomogeneity in micromechanical properties of the sample surface. The purpose of this investigation is to demonstrate how the phase contrast images contribute to the characterization of thin tribofilms.

  • PDF