• Title/Summary/Keyword: perturbation and observation

Search Result 74, Processing Time 0.02 seconds

Analog MPPT Tracking MPP within One Switching Cycle for Photovoltaic Applications (One Switching Cycle 내에 최대전력점을 추종하는 태양광 발전의 아날로 MPPT 제어 시스템)

  • Ji, Sang-Keun;Kwon, Doo-Il;Yoo, Cheol-Hee;Han, Sang-Kyoo;Roh, Chung-Wook;Lee, Hyo-Bum;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Tracking the Maximum Power Point(MPP) of a photovoltaic(PV) array is usually an essential part of a PV system. The problem considered by MPPT techniques is to find the voltage $V_{MPP}$ or current $I_{MPP}$ at which a PV array should operate to generate the maximum power output PMPP under a given temperature and irradiance. The MPPT control methods, such as the perturb and observe method and the incremental conductance method require microprocessor or DSP to determine if the duty cycle should be increased or not. This paper proposes a simple and fast analog MPPT method. The proposed control scheme will track the MPP very fast and its hardware implementation is so simple, compared with the conventional techniques. The new algorithm has successfully tracked the MPP, even in case of rapidly changing atmospheric conditions, and Has higher efficiency than ordinary algorithms.

Study on maximum power point tracking method for PV system under varying irradiance (일사량 변동에 대응한 태양광발전시스템의 최대전력 추종기법 연구)

  • Yu, Byung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5310-5316
    • /
    • 2013
  • Maximum Power Point Tracking (MPPT) method for Photovoltaic (PV) system is implemented in PV inveter and it generate the maximum electric power from PV cell. MPPT method has been studied to have high efficiency and high tracking speed. However, these studies are basically focused on the performance under fixed irradiance condition. Based on the typical Perturbation and Observation (P&O) method, this paper presents the research results on modified P&O method to have a better performance under varying irradiance condition. The modified P&O method can have a better performance under varying irradiance condition because the additional measurements during the MPPT control period are conducted. The proposed MPPT method is verified by using 250kW PV inverter under linearly varying irradiance condition according to EN 50530.

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.

Observation of the Mesoscale Phenomena by Ocean Acoustic Tomography in the East Sea (동해에서 해양음향토모그래피에 의한 중규모 현상 관측)

  • Na, Jung-Yul;Han, Sang-Kyu;Lee, Jae-Hak;Shim, Tae-Bo;Kim, Kuh
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.3
    • /
    • pp.170-179
    • /
    • 1999
  • The SUS (Signal, Underwater Sound)-OAT experiment was carried out in the Ulleung Basin of the East Sea on 3 June 1997. The SUS-OAT system consisted of aircraft deployed shots as sources and a vertical line array (VLA) tethered by a receiver ship was used to survey a large area where a mesoscale warm eddy appears frequently. The experiment was carried out such that explosive charges set to detonate at 800 ft depth were dropped in a rectangular ($120{\times}120$ km). Sources were a rapidly deployable SUS charge (MK 61 MOD 0), and receiver is a fixed VLA, 90 m in length (150-240 m in receiver depth), composed of 10 elements equally spaced. The reference ray paths are computed by range-dependent acoustic model in canonical ocean based on the historical data. The singular value decomposition (SVD) method is used to obtain the horizontal perturbation of the temperature fields. Horizontal distributions of temperature fields at 150 m and 200 m depth show a weak warm eddy observed by AXBT and the inversely estimated temperature shows similar patterns in terms of the location of the warm eddy. In conclusion, the SUS-OAT experiment has been successful to estimate the position of warm eddy and its temperature field in the East Sea of Korea.

  • PDF