The Performance Test of Teledyne PB-3 Personnel Dosimetry System by Intercomparison Study (국제상호비교검증을 통한 Teledyne PB-3 개인선량계시스템의 성능시험)

  • Lee, Sang-Yoon;Lee, Hyung-Sub;Kim, Jung-Lyul;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.133-145
    • /
    • 1994
  • Recently, the Ministry of Science and Technology issued a Ministerial Ordinance (No 1992-15) about the technical criteria on personnel radiation dosimetry. In today's climate, it is important to demonstrate and document that the processor's systems and services to others meet national standards of quality. The purpose of this study is to verify the performance of the Teledyne PB-3 personnel dosimetry system that is generally used in Korea Atomic Energy Research Institute(KAERI) by intercomparison with Oak Ridge National Laboratory. The KAERI has been participated in this personnel dosimetry intercomparison study(PDIS) program since 1991 and it could be possible to test and calibrate personnel monitoring system. This report presents a summary and analysis of by about 50 dose equivalent measurements reported for PDIS-16 through 18 (1991 -1993) with emphasis on neutron dose equivalent sensitivity, accuracy and precision. Relationships of the PDIS results to occupational neutron monitoring and methods to improve personnel dosimetry performance are also discussed.

  • PDF

Personnel Dosimetry Performance Test (개인방사선 피폭선량판독 성능시험)

  • Na, Seong-Ho;Han, Seung-Jae;Lee, Dew-Hey;Cho, Dae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.131-138
    • /
    • 1996
  • This paper describes the methods and results of the personnel dosimetry performance tests which were been implemented for the first time in Korea in 1995. Seven categories, except the neutron category prescribed in the ANSI N13.11-1993, were adopted in the test. Fifteen types of dosimeters were participated by fourteen dosimeter processing institutes. A total of 129 dosimeters were selected to test-each type - 15 dosimeters for each of the seven categories and 24 for the controls. A total of 144 radiation categories were employed in the test and a total of 2560 (including 400 controls)dosimeters were submitted-7 categories for each type of the fifteen types dosimeters and 39 categories for the retest. The performance index in each category. sum of the absolute value of the bias and the standard deviation value of the performance quotient. was estimated by the use of delivered and processed dose equivalents according to the standard procedure. The performance in a given category was assessed as acceptable, for the deep and shallow dose equivalents (or the absorbed dose), if the performance index was less than 0.5. The test results showed 54% of the processors passed in the first test, 33% in the retest and 13% in the second retest.

  • PDF