Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

A Study on the Properties of CSPE According to Accelerated Thermal Aging Years

  • Lee, Jung-Hoon;Kang, Myeong-Kyun;Jeon, Jun-Soo;Lee, Seung-Hoon;Kim, In-Yong;Park, Hyun-Shin;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.643-648
    • /
    • 2014
  • The accelerated thermal aging of CSPE (chlorosulfonated polyethylene) was carried out for 40.41, 121.22, and 202.04 days at $100^{\circ}C$, which are equivalent to 20, 60, and 100years of aging at $50^{\circ}C$, respectively. The volume electrical resistivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $1.107{\times}10^{14}-2.097{\times}10^{14}$, $7.752{\times}10^{13}-1.556{\times}10^{14}$, $7.693{\times}10^{13}-1.521{\times}10^{14}$, and $7.380{\times}10^{13}-1.304{\times}10^{14}{\Omega}{\cdot}cm$, respectively, at room temperature. The permittivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $2.89{\times}10^{-11}-3.65{\times}10^{-11}$, $3.40{\times}10^{-11}-3.70{\times}10^{-11}$, $3.50{\times}10^{-11}-3.82{\times}10^{-11}$, and $3.76{\times}10^{-11}-4.13{\times}10^{-11}$ F/m, respectively, at room temperature. The EAB (elongation at break) of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 98.8-101.3, 59.5-60.3, 37.8-39.2, and 41.8-44.3%, respectively, at room temperature. The apparent densities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 1.603-1.614, 1.611-1.613, 1.622-1.628, and $1.618-1.620g/cm^3$, respectively, at room temperature. The measured currents of the accelerated thermally aged CSPE and the standard sample were almost constant after 5 min of applying a 300-V/mm electric field to the CSPE. The V-I slope of the accelerated thermally aged CSPE sample was increased if the applied electric field was increased at room temperature, and the V-I slope of the accelerated thermally aged CSPE was higher than that of standard CSPE.

5.2 GHz 무선 LAN의 전자파 환경 대책용 전파흡수체에 관한 연구 (A Study on EM Wave Absorber for Electromagnetic Wave Environment of Wireless LAN at 5.2 GHz)

  • 유건석;최동수;김동일
    • 한국항해항만학회지
    • /
    • 제34권1호
    • /
    • pp.15-19
    • /
    • 2010
  • 최근 빠르고 편리하게 데이터 송수신이 가능한 무선LAN은 가정, 사무실 등 다양한 장소에서 사용이 증가하고 있다. 그러나 실내에서 무선LAN을 사용할 경우 천장, 벽, 바닥, 책상 등에서의 반사파에 의한 다중반사가 발생하여 데이터 전송의 오류 및 성능 저하의 주된 원인이 된다. 이를 해결하기 위해 본 논문에서는 Graphite의 특성을 분석하고 최적의 조성비를 찾아내서 무선LAN 환경에 적합한 전파흡수체를 연구하였다. 먼저 Graphite와 지지재인 CPE(Chlorinated Polyethylene)를 이용하여 조성비별 전파흡수체 샘플을 제작하고, 각 샘플의 반사계수를 측정하였다. 측정된 데이터로부터 재료정수를 계산하고, 전파흡수체를 설계 및 제작하여 전파흡수능을 비교, 분석 하였다. 그 결과 조성비가 Graphite : CPE=50:50 wt%이고, 두께 1.7 mm 인 전파흡수체가 5.2 GHz에서 27 dB 이상의 전파흡수능을 가지는 우수한 전파흡수체를 개발하였다.

GPR 기반 콘크리트 슬래브 시공 두께 검측 기법 개발 (Development of Thickness Measurement Method From Concrete Slab Using Ground Penetrating Radar)

  • 이태민;강민주;최민서;정선응;최하진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.39-47
    • /
    • 2022
  • 국내의 공동주택 보급률 증가에 따라 층간소음으로 인한 문제가 증가하고 있다. 이를 예방하기 위하여 바닥 충격음 차단 구조에 대한 수요가 높아지고 있으며 해당 구조에 대한 성능 인증이 이뤄지고 있지만 소음 차단 성능이 현장에서는 재현되지 않는다는 문제점이 있다. 해당 구조가 제 성능을 발휘하기 위해서는 일정 두께 이상의 마감 모르타르 타설이 필요하며, 해당 구조의 시공 적정성 판정을 위하여 GPR을 이용한 두께 측정 실험을 진행하였다. 본 연구에서 개발한 두께 측정 알고리즘은 측정된 데이터를 기반으로 상대유전율을 설정할 수 있어 정확한 두께 값을 측정할 수 있다. 네 종류의 바닥 충격음 차단 인증 구조에서 GPR 두께 측정 실험을 진행하였으며, GPR 데이터와 천공 측정 데이터 간 평균 오차는 1.95mm로 나타났다. 또한 마감재 유무가 측정값에 미치는 영향을 조사하기 위하여 총 3가지 종류의 마감재를 배치하고 실험을 진행으며, 평균 오차는 1.70mm로 나타났다. 추가적으로 장비의 샘플링 오차, 개발 알고리즘 변수, 천공 오차등을 종합적으로 고려하였을 때, GPR 계측 및 제안 알고리즘은 매우 높은 정확도로 슬래브 마감 모르타르의 두께 측정에 적용할 수 있음을 확인하였다.

Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구 (Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film)

  • 김성훈;김영진;이명자;전하정;이병용
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.11-21
    • /
    • 1998
  • 일렉트릿 (electret) 의 특성을 갖고 있는 Teflon-FEP 와 PET 필름의 유전체 양변에 크롬을 증착시켜 전극을 만들고 코발트-60 감마선을 찍어 이 두 유전체의 물리적 특성변화를 조사하였다. 선량률 25.0 cGy/min에서 방사선 조사하기 시작하여 2초이내에서 전류가 급격히 증가해 최대값에 이른후, 60초 이후에선 거의 안정값에 이르는 특성을 보였다. 방사선 조사동안 Teflon의 경우 유전 상수는 2.15에서 18.0으로, 전기전도도는 1$\times$$10^{-17}$ 에서 1.57$\times$$10^{-13}$ $\Omega$$^{-l}$ $cm^{-1}$ /으로 증가했고, PET는 유전상수는 3에서 18.3으로, 전기전도도는 $10^{-17}$ 에서 1.65$\times$$10^{-13}$ $\Omega$$^{-1}$$cm^{-1}$ /값으로 변하였다. 분당선량률을 변화시켰을때 (4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) 정상상태 방사선 유도전류(Ic), 유전율($\varepsilon$), 전기전도도 ($\sigma$) 가 선량률에 따라 증가함을 보였다. 정상상태방사선유도전류(Ic)값은 12시간내에선 1%내의 재현성을 보였고, 1주일간에선 3%내에서 일치하였다. 전하 및 전류값이 측정간격 (방사선 조사후 다음 조사때까지의 시간)에 의존성을 보였으며, 측정간격이 작을수록 초기측정값과 후측정값의 차가 크며, 최소 20분이상 간격을 둘 때 후측정값이 초기측정값과 같아졌다. 25.0 cGy/min. 선량률에서 유전체가 20분동안 전하를 유지하는 일펙트릿 성질을 갖고 있음을 보였다. 위 실험결과들은 2차전자에 의한 자유전자와 정공의 발생 및 이로 인한 내부편극과 전도도의 변화, 재결합등으로 인한 전자평형상태에 의한 것으로 볼 수 있다. 방사선조사직후 시료에 열을 가한 후 다시 조사하면 측정값이 상승하는 현상을 보였다. 이는 열을 가함으로 내부편극이 감소되었고 이로인해 다음 방사선 조사시 전하운반자(charge carriers)의 숫자를 높이는데 기여했음을 알 수 있다. 인가전압 및 흡수선량에 따른 선형성 및 재현성과 다른 전리함에 비해 적은 부피로 큰 전하량을 측정하는 것은 미세전류검출기로서의 사용가능성과 검출기의 부피를 크게 줄일수 있는 가능성을 보여준다.

  • PDF