• Title/Summary/Keyword: permanent gas

Search Result 104, Processing Time 0.02 seconds

Experimental Results of New Ion Source for Performance Test

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

Automatic Classification by Land Use Category of National Level LULUCF Sector using Deep Learning Model (딥러닝모델을 이용한 국가수준 LULUCF 분야 토지이용 범주별 자동화 분류)

  • Park, Jeong Mook;Sim, Woo Dam;Lee, Jung Soo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1053-1065
    • /
    • 2019
  • Land use statistics calculation is very informative data as the activity data for calculating exact carbon absorption and emission in post-2020. To effective interpretation by land use category, This study classify automatically image interpretation by land use category applying forest aerial photography (FAP) to deep learning model and calculate national unit statistics. Dataset (DS) applied deep learning is divided into training dataset (training DS) and test dataset (test DS) by extracting image of FAP based national forest resource inventory permanent sample plot location. Training DS give label to image by definition of land use category and learn and verify deep learning model. When verified deep learning model, training accuracy of model is highest at epoch 1,500 with about 89%. As a result of applying the trained deep learning model to test DS, interpretation classification accuracy of image label was about 90%. When the estimating area of classification by category using sampling method and compare to national statistics, consistency also very high, so it judged that it is enough to be used for activity data of national GHG (Greenhouse Gas) inventory report of LULUCF sector in the future.

Growth and Physiological Characteristics of Five Common Foliage Plant Species Grown under the Influence of Static Magnetic Field (정자기장 처리에 따른 실내 관엽식물의 생육 및 생리적 특성 변화)

  • Lee, Seong Han;Woo, Su Young;Kwak, Myung Ja
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.484-492
    • /
    • 2012
  • The present study aimed to investigate the effect of static magnetic field (SMF) on the growth and physiological characteristics of common indoor plant species. Five foliage plant species, Spathiphyllum spp., Ardisia pusilla DC., Syngonium podophyllum, Peperomia pereskiifolia, and Pilea cadierei were potted into plastic pot equipped with round type anisotropic sintered NdFeB permanent magnet inside the pot. The surface magnetic flux density of each magnet was 3,500 G. After 6 months of growth period, the biomass accumulations of Spathiphyllum, A. pusilla, and P. cadierei under SMF were statistically higher than those of controls. Tissue water content also increased under the influence of SMF in most species. The photosynthetic rate of Spathiphyllum under SMF significantly increased but other species showed no significant difference compared with control. Although there was no significant increase in the photosynthetic rates of A. pusilla, and P. cadierei, they showed remarkable increase in total fresh weight under SMF. This suggests that the demand of assimilates for normal metabolism could be decreased under magnetic influence and thereby biomass accumulation could be more favored. But this is not always true for all plant species because P. pereskiifolia in this experiment, showed no changes in both photosynthetic rate and biomass accumulation. Leaf nitrogen and chlorophyll contents were enhanced significantly in most plant species under influence of SMF. Chlorophyll a/b ratio also increased by SMF. Although there might be a limitation depending on plant species, these results suggest that long-term exposure to SMF might allow plant to have an enhanced acclimation capacity against environmental fluctuations and optimal application of SMF could increase the practical use of indoor plants such as an attempt to improve indoor air quality.

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF