• Title/Summary/Keyword: period ratio

Search Result 5,200, Processing Time 0.032 seconds

Effects of the Low Temperature and Low Salt Solution on the Quality Characteristics of Salted Chinese Cabbage (저온-저염 절임기술이 절임배추의 품질 특성에 미치는 영향)

  • Lee, Seog-Won;Cho, Sun-Rae;Han, Sung-Hee;Rhee, Chul
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.3
    • /
    • pp.377-386
    • /
    • 2009
  • The principal objective of this study was to evaluate the influence of temperature and salt concentration on the physicochemical properties of salted Chinese cabbage. Salted Chinese cabbage samples were prepared with various concentrations of salt(4, 5, 6 and 7%), and were stored for 10 days at three temperatures(8, 14, and $25^{\circ}C$). The salting ratio of Chinese cabbage evidenced a decreasing trend regardless of the salting temperature and salt concentration, and their decrement appeared relatively high as the salting temperature increased. The period required to achieve a critical salting ratio(85%) decreased with increases in the salt concentration at $25^{\circ}C$, and a similar trend was observed at lower temperatures(8 and $14^{\circ}C$). The salinity of all samples evidenced an increasing trend during the salting period, and at $25^{\circ}C$, in particular, a continuous increment was observed. At salt concentrations of 4%, the critical salinity(2.2%) was not achieved regardless of the temperature and salting period. The pH of salted Chinese cabbage achieved critical pH in 3 days at a salting temperature of $25^{\circ}C$, but the critical pH 5.5 of samples at 8 and $14^{\circ}C$ appeared after a long period of approximately 4 to 10 days. The average hardness values of salted Chinese cabbage at a salting ratio of 85% were approximately 1.49 MPa, 1.87 MPa, and 1.97 MPa, respectively, at three temperatures($25^{\circ}C$, $14^{\circ}C$, and $8^{\circ}C$). The initial reducing sugar content of cabbage juice was 11.8 mg/$m{\ell}$, and this value decreased substantially to 3 to 5 mg/$m{\ell}$ on day 1.

The Study on Relation between Six Sigma Implemented Period and Financial Performance: Using Smoothing Spline Function (식스 시그마 도입기간이 기업의 재무적 성과에 미치는 영향 연구: 평활 스플라인 함수를 이용하여)

  • Ryu, Changheon;Park, Minjae
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.78-89
    • /
    • 2016
  • Purpose: In this paper, we investigate whether the endeavors for Six Sigma quality management by a firm have positive effects on its financial performance and the length of Six Sigma implemented period affects its financial status. We find a relationship between Six Sigma implemented period and several financial performance index using a smoothing spline function. Methods: A smoothing spline function is used in order to analyze the relationship between efforts for quality management and financial performance. Specifically, the return on assets, return on equity, sales cost and business fee are investigated as dependent variables and the efforts for quality management as independent variable. Results: As a result of the analysis, the indication is that companies that put effects into the Six Sigma quality management have a positive result in its financial status. In detail, the efforts for Six Sigma quality management have positive effects on total asset turnover ratio and Six Sigma implemented period on net income to net sales ratio. Additionally, companies with longer (shorter) period of Six Sigma program have more (less) improvement in its financial status. Conclusion: It can be concluded that the company's efforts for quality management positively influence financial performance.

Wind Induced Vibration Design for High-rise buildings through Control of Natural Period (주기 조절을 이용한 고층 건물의 풍응답 조절 설계)

  • 김지은;차성희;서지현;박효선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.43-51
    • /
    • 2004
  • As the slenderness ratio of a high-rise building increases, the lateral load resisting system for the building is more often determined by serviceability design criteria. In serviceability design, the maximum drift and the level of vibration are controlled not to exceed the design criteria. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. Development of practical design method for wind induced vibration is required. Generally, wind induced acceleration responses are depending on several variables such as the weight density of a building, damping ratio, the natural period, and etc.. All parameters except the natural period or frequency are usually out of reach for structural engineers, then the wind acceleration response may be proportioned to the natural period. Therefore, in this paper, a wind induced vibration design method based on frequency control technique for high-rise is proposed. The method is applied to vibration design of a 25-story office building for performance evaluation.

  • PDF

Response Modification Factors of Non-seismic School Buildings Considering Short Column Effects and Natural Period (단주효과 및 고유주기를 고려한 비내진 학교시설의 반응 수정계수)

  • Kim, Beom Seok;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.201-209
    • /
    • 2019
  • Response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills in 'Manual for Seismic Performance Evaluation and Retrofit of School Facilities' published in 2018 were investigated in the preceding study. However, since previous studies are based on 2D frame analysis and limited analysis conditions, additional verification needs to be performed to further apply various conditions including orthogonal effect of seismic load. Therefore, this study is to select appropriate response modification factors of school facilities for non-seismic RC moment frames with partial masonry infills by 3D frame analysis. The results are as follows. An appropriate response modification factor for non-seismic RC moment frames with partial masonry infills is proposed as 2.5 for all cases if the period is longer than 0.6 seconds. Also if the period is less than 0.4 seconds and the ratio of shear-controlled columns is less than 30%, 2.5 is chosen too. However, if the period is less than 0.4 seconds and the ratio of shear-controlled columns is higher than 30%, the response modification factor shall be reduced to 2.0. If the period is between 0.4 and 0.6 seconds, then linearly interpolates the response correction factor.

A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia (인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석)

  • Song, Ju Hyun;Kim, Kyung Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

Differences in Nymphal Development, Adult Longevity and Fecundity of the Green Rice Leafhopper, Nepthotettix cincticeps Uhler Fed on Rice Cultivar and Water Foxtail, Alopecurus aequalis Sobol. Var. amurensis Ohwi at Various Temperatures (벼와 벼과 잡초에 따른 끝동매미충 유충의 발육 및 성충의 수명과 산란의 차이)

  • 최주수;박영도
    • Journal of Life Science
    • /
    • v.11 no.2
    • /
    • pp.121-125
    • /
    • 2001
  • Some attempts were made to investigate the biological characterisitcs of the green rice leafhopper(GLH) , Nepthotettix cincticeps Uhler in terms of nymphal development, emergence ratio. preovipositional period, growth index, adult longevity and fecundity fed on rice cultivar, Chucheongbyeo with no resistance gene and water foxtail, Alpecurus aequalis Sobol. var. amurensis Ohwi at 20 and $25^{\circ}C$ with a 16L;8D photoperiod. Development period of nymph on rice cultivar and water foxtail at $25^{\circ}C$ was shorter than that at 2$0^{\circ}C$ by twofold. The nymphal period of female was about one day longer than that of male. The mean emergence ratio of female and male on rice cultivar and water foxtail was 40.0, 76.7, 38.3, 73.3% at 20 and $25^{\circ}C$, respectively. Preovipositional period on rice cultivar and water foxtail at $25^{\circ}C$ was shorter that at 2$0^{\circ}C$ by twofold. Growth index on rice cultivar adn water foxtail at $25^{\circ}C$was higher than that at 2$0^{\circ}C$ by fourfold. Under the 20 and $25^{\circ}C$ condition, the longevity of female and male was longer on water foxtail than on rice cultivar, but the fecundity of GLH was higher on rice cultivar than on water foxtail. In conculsion, water foxtail seems to be adequate for spring host of GLH.

  • PDF

Service life evaluation of HPC with increasing surface chlorides from field data in different sea conditions

  • Jong-Suk Lee;Keun-Hyeok Yang;Yong-Sik Yoon;Jin-Won Nam;Seug-Jun Kwon
    • Advances in concrete construction
    • /
    • v.16 no.3
    • /
    • pp.155-167
    • /
    • 2023
  • The penetrated chloride in concrete has different behavior with mix proportions and local exposure conditions, even in the same environments, so that it is very important to quantify surface chloride contents for durability design. As well known, the surface chloride content which is a key parameter like external loading in structural safety design increases with exposure period. In this study, concrete samples containing OPC (Ordinary Portland Cement), GGBFS (Ground Granulated Blast Furnace Slag), and FA (Fly Ash) had been exposed to submerged, tidal, and splash area for 5 years, then the surface chloride contents changing with exposure period were evaluated. The surface chloride contents were obtained from the chloride profile based on the Fick's 2nd Law, and the regression analysis for them was performed with exponential and square root function. After exposure period of 5 years in submerged and tidal area conditions, the surface chloride content of OPC concrete increased to 6.4 kg/m3 - 7.3 kg/m3, and the surface chloride content of GGBFS concrete was evaluated as 7.3 kg/m3 - 11.5 kg/m3. In the higher replacement ratio of GGBFS, the higher surface chloride contents were evaluated. The surface chloride content in FA concrete showed a range of 6.7 kg/m3 to 9.9 kg/m3, which was the intermediate level of OPC and GGBFS concrete. In the case of splash area, the surface chloride contents in all specimens were from 0.59 kg/m3 to 0.75 kg/m3, which was the lowest of all exposure conditions. Experimental constants available for durability design of chloride ingress were derived through regression analysis over exposure period. In the concrete with GGBFS replacement ratio of 50%, the increase rate of surface chloride contents decreased rapidly as the water to binder ratio increased.

Photoperiodic modulation of insect circadian rhythms

  • Tomioka, Kenji;Uwozumi, Kouzo;Koga, Mika
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.9-12
    • /
    • 2002
  • Circadian rhythms can be seen in a variety of physiological functions in insects. Light is a powerful zeitgeber not only synchronizing but also modulating the rhythm to adjust insect's temporal structure to seasonal changes in the environmental cycle. There are two general effects of the length of light phase within 24 hr light cycles on the circadian rhythms, i.e., the modulation of free-running period and the waveform. Since the photoperiodic modulation of the free-running period is induced even in the clock mutant flies, per$\^$s/, the free-running period is not fully determined genetically. In crickets, the ratio of activity (a) and rest phase (p) under the constant darkness (DD) is clearly dependent on the photoperiod under which they have been kept. When experienced the longer photoperiod it becomes smaller. The magnitude of change in a/p-ratio is dependent on the number of cycles they experienced. The neuronal activity of the optic lobe in DD shows the a/p-ratio changing with the preceding photoperiod. These data suggest that a single circadian pacemaker stores and maintains the photoperiodic information and that there is a system that accumulates the effects of single photoperiod to cause greater effects.

  • PDF

Transmission Characteristics of Long-Period Fiber Gratings Using Periodically Corroded Single-Mode Fibers

  • Lee, Jonghwan;Bang, Ngac An;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.376-381
    • /
    • 2015
  • Transmission characteristics of long-period fiber gratings (LPFGs) fabricated by periodically etching a conventional single-mode fiber (SMF) are investigated. After coating the SMF with photoresist, the cladding of the SMF is symmetrically and periodically removed by using a wet etching technique resulting in the formation of the LPFG. Tensile strain reinforces the coupling strength between the core and the cladding mode based on the photoelastic effect. The extinction ratio of the SMF-based LPFG at a wavelength of 1550.8 nm is measured to be -15.1 dB when the applied strain is $600{\mu}{\varepsilon}$. The ascent of ambient index shifts the resonant wavelength to shorter wavelength because of the increase of the effective refractive index of the cladding mode. The extinction ratio is diminished by increase in the ambient index because of the induction of the optical attenuation of the cladding mode. The transmission characteristics of the proposed LPFG with variations in torsion are also measured. The photoelastic effect based on torsion changes the extinction ratio and the resonant wavelength of the proposed SMF-based LPFG. The polarization-dependent loss of the LPFG is also increased by torsion because of the torsion-induced birefringence. The polarization-dependent loss of the LPFG at torsion of 8.5 rad/m is measured to be 3.9 dB.

Estimation of Degradation Period Ratio for Adaptive Framework in Mobile Cellular Networks (이동 통신망에서 적응형 구조의 호 저하 시간 비율 추정)

  • Jeong Seong Hwan;Lee Se Jin;Hong Jeong Wan;Lee Chang Hun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.441-447
    • /
    • 2003
  • Recently there is a growing Interest In mobile cellula r network providing multimedia service. However, the link bandwidth of mobile cellular network is not sufficient enough to provide satisfactory services to use rs. To overcome this problem, an adaptive framework has been proposed in this study, we propose a new method of estimating DPR(degradation period ratio) in an adaptive multimedia network where the bandwidth of ongoing call can be dynamically adjusted during its lifetime. DPR is a QoS(quality of service) parameter which represents the ratio of allocated bandwidth below a pre-defined target to the whole service time of a call. We improve estimation method of DPR using DTMC(discrete time Markov chain) model. We also calculate mean degradation period and degradation probability more precisely than in existing studies. Under Threshold CAC(call admission control) algorithm, we present analytically how to guarantee QoS to users and illustrate the method by numerical examples. The proposed method is expected to be used as one of CAC schemes in guaranteeing predefined QoS level of DPR

  • PDF