• Title/Summary/Keyword: perfusion

Search Result 1,259, Processing Time 0.036 seconds

Implementation of Non-Invasive Cerebral Perfusion Platform (비침습적 대뇌관류 장치의 구현)

  • Kwon, Seong-tae;Lee, Jean;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.1016-1026
    • /
    • 2017
  • Shipping Along with the aging of the total population, its importance is greater cause of stroke, which is one of the diseases are listed cerebral perfusion is about 80%,.ie that the flow of blood flowing to the brain is reduced as the cause. One of the most typical prophylaxis and treatment of these stroke is to enhance cerebral perfusion. There are several ways to increase cerebral blood flow are a therapy through drugs, through surgery and invasive NeuroFlo. NeuroFlo is to insert a catheter to which a balloon is attached into a patient's artery. However, since the method of enhancing conventional cerebral perfusion have been conducted mainly in invasive method, giving a burden to the patient, the problem of inducing a number of complications were noted. In this paper, an attempt to supplement the shortcomings of such invasive brain perfusion increase method, to provide a device to enhance the non-invasively brain perfusion.

The Changes of Growth Patterns and the Production of Brain-Derived Neurotrophic Factors (BDNFs) in Perfusion Cultivation of Human Neuroblastoma Cells

  • Hong, Jong-Soo;Lee, Joo-Nho;Kim, Sun-Hee;Park, Kyung-Yoo;Cho, Jin-Sang;Lee, Hyeon-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.3
    • /
    • pp.323-327
    • /
    • 1999
  • It was shown that brain-derived neurotrophic factors (BDNFs) secreted from human neuroblastoma cells can significantly improve the growth of the neurites of PC12 nerve cells. The addition of purified BDNFs elongated the neurites of PC 12 nerve cells two to three times more than the case where the addition was not made. The perfusion rate strongly affected the change of the size of human neuroblastoma cells because the cell size decreased as the perfusion rate increased. This could also influence the productivity of BDNF from the cells. It is also important to note that the BDNF production was decreased when the cell size was reduced. BDNF production rate also decreased at a fast perfusion rate in a smaller cell size. At the relatively fast perfusion rate of 18 ml/h, the ratio of apoptotic to necrotic cells dramatically decreased, which possibly caused the decrease of BDNF production. It has been proven that the secretion of BDNF from human neuroblastoma cells was a partially growth-related process by yielding 6.2$\times l0^{-8}/g$ of BDNF/cell/h of growth related parameter and $0.48{\times}l0^{-9}/g$ of BDNF/cell/h of nongrowth-related parameter in a growth kinetic model. In addition, it was also found that the perfusion rate played a very important role in controlling the cell death mechanism.

  • PDF

Hepatic Arterial Perfusion Scintigraphy with Tc-99m-Macroaggregated Albumin in Hepatocellular Carcinoma (Tc-99m-MAA를 이용한 간세포암의 경동맥 관류스캔)

  • Kim, Gang-Deuk;Sohn, Kwang-Joon;Min, Kyung-Yoon;Kwon, Young-Mi;Kim, Chang-Guhn;Noh, Byung-Suk;Won, Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.350-356
    • /
    • 1994
  • Purpose : Hepatic arterial perfusion scintigraphy with Tc-99m-macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma(HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and usefullness of HAPS. Materials and Methods : HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4-5 mCi of MAA mixed with 2ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1ml/sec. We analysed 21 HCCs over 2cm in diameter(average diameter; 6.4cm) and 17 of 21 HCCs were over 4cm in diameter(Table 1). CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Results : Three different pattern of tumor perfusion were observed in 16 patients with HCC (Table 2). 1) diffuse increased perfusion in 16 of 21(76%)(Fig. 1) 2) increased peripheral perfusion in 4 of 21(19%) (Fig. 2) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16(56%)(Fig. 4). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16(13%). There was no accumulation of radioactivity on RBC-blood pool scan in all six patients with HCC examined (Fig. 1). Conclusion : HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  • PDF

Comparison Between TCDD and 3MC Action on CYP1A1 Expression and EROD Activity in the Isolated Perfused Female Rat Liver

  • Ahn, Mee R.;Sheen, Yhun Y.
    • Toxicological Research
    • /
    • v.14 no.4
    • /
    • pp.587-594
    • /
    • 1998
  • In order to understand the mechanism if the regulation of CYP 1A1 gene expression and ethoxyresorufin deethylase (EROD) activity in ex vivo system, we have studied the action of TCDD and 3MC in the isolated perfused female rat liver. CYP1A1 mRNA level and EROD activity were measured in rat liver that was isolated and perfused with various chemicals such as 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 3-methylcholanthrene (3MC), 17$\beta$-estradiol (E$_2$), morin. TCDD or 3MC alone perfusion into female rat liver resulted in increase of CYP 1A1 mRNA level and the magnitude of stimulation was six times higher with TCDD treatment than 3MC treatment. However E$_2$ perfusion into female rat liver showed inhibition of CYP 1A1 mRNA level. When 10$^{-8}$ M E$_2$ was administered concomitantly with either 10$^{-9}$ M TCDD or 10$^{-9}$ M 3MC, stimulated CYP 1A1 mRNA by either TCDD or 3MC was inhibited. Morin was examined for its effects on CYP 1A1 mRNA level and result was similar to that was observed with estrogen. EROD activity was also stimulated with either TCDD or 3MC perfusion, and the magnitude of EROD stiumlation was smaller than that of CYP 1A1 mRNA stimulation in response to TCDD or 3MC perfusion. Unlike CYP1A1 mRNA level, stimulation of EROD activity was greater with 3MC than TCDD. Concomitant perfusion either E$_2$ or morin with TCDD or 3MC inhibited 3MC perfusion or TCDD perfusion stimulated EROD activity. These data suggested that TCDD and 3MC might act diffrently in terms of regulation of CYP 1A1 gene expression in rat liver.

  • PDF

Hemodynamic Outcome of Successful Bypass Surgery in Patients with Atherosclerotic Cerebrovascular Disease: A study with Acetazolamide and $^{99m}Tc-ECD$ SPECT (죽상경화성 뇌혈관질환 환자에서 성공적인 EC/IC 우회술 후 혈류역학적 변화: 기저/아세타졸아미드 SPECT를 이용한 연구)

  • Eo, Jae-Seon;Oh, Chang-Wan;Kim, Yu-Kyeong;Park, Eun-Kyung;Lee, Won-Woo;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.293-301
    • /
    • 2006
  • Purpose: The aim of the study was to evaluate the hemodynamic changes after successful bypass surgery in patients with atherosclerotic stenosis in ICA using $^{99m}Tc-ECD$ SPECT. Materials and Methods: Fourteen patients (M:F=8:6, mean age; $60{\pm}9$ years) who underwent STA-MCA anastomosis for unilateral atherosclerotic cerebrovascular disease were enrolled. $^{99m}Tc-ECD$ basal/acetazolamide perfusion SPECT studies were performed before, 10 days and 6 months after bypass surgery. Perfusion reserve was defined as the % changes after acetazolamide over rest image. Regional cerebral blood flow and perfusion reserve were compared preoperative, early-postoperative and late-postoperative scans. Results: The mean resting perfusion and decrease in perfusion reserve in affected ICA territory on preoperative scan was $52.4{\pm}3.5\;and\;-7.9{\pm}4.7%$, respectively. The resting perfusion was significantly improved after surgery on early-postoperative scan (mean $53.7{\pm}2.7$) and late-postoperative scan (mean $53.3{\pm}2.5$) compared with preoperative images (p<0.05, respectively). Resting perfusion did not showed further improvement on late-postoperative scan compared with early-postoperative scan. The perfusion reserve was $-3.7{\pm}2.6%$ on early-postoperative scan, and $-1.6{\pm}2.3%$ on late-postoperative scan, which was significantly improved after surgery. Additionally, further improvement of perfusion reserved as observed on late-postoperative scan (p<0.05). While, in the unaffected ICA territory, no significant changes in the resting perfusion and perfusion reserve was observed. Conclusion: The improvement of resting perfusion and perfusion reserve in early-postoperative scan reflects the immediate restoration of the cerebral blood flow by bypass surgery. In contrasts, further improvement of perfusion reserve showing on late-postoperative scan may indicate a good collateral development after surgery, which may indicate good surgical outcome after surgery.

Effects of Perfusion Defect on the Measurement of Left Ventricular Mass, Ventricular Volume and Post-stress Left Ventricular Ejection Fraction in Gated Myocardial Perfusion SPECT (정량적 게이트 심근관류 스펙트 검사에서 관류결손이 좌심근질량 측정과 부하 후 좌심실 용적 및 구혈률에 미치는 영향)

  • Ahn, Byeong-Cheol;Bae, Sun-Keun;Lee, Sang-Woo;Jeong, Sin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.381-391
    • /
    • 2002
  • Purpose: The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluate the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Subjects and Methods: Forty-six patients (male/female=34:12, mean age=64years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by AutoQUANT program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. Results: LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS un patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between EDVs, ESVs, EFs than patients with reversible defect. Conclusion: These results suggest that perfusion defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography (초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구)

  • Lee, Jong-Seok;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.149-160
    • /
    • 2007
  • Recent advent of 64-multidetctor (MD) CT enables more coverage of Z-axis in the perfusion imaging. The purpose of this study was to evaluate the clinical usefulness of perfusion CT by using 64-MD CT in detecting the lesion in patients with acute stroke. The perfusion CT was performed by using 64-MD CT in 62 consecutive patients who were initially suspected to have subacute ischemic stroke symptoms during the period of recent 9 months. These patients had subacute stroke (n=62). CT scanning was conducted with Jog Mode which provided 16 imaging slices with 5 mm of slice thickness, and 8 cm of coverage in Z-axis. Scan interval was 1 seconds for each imaging slice and total 15 scans were repeated. After CT scanning, perfusion maps (CBV, CBF, MTT and TTP) were created at Extended Brilliance Workstation. The CBV and CBF maps showed that lesions were smaller images. While on the MTT and TTP map lesions were seen to be larger fifty-one were large than they appeared on these images. Two slices of perfusion maps obtained at the level of the basal ganglia were chosen to simulate conventional older perfusion CT with 8 cm of coverage in Z-axis. TTP and MTT maps may be clinically useful for evaluation of the penumbral zone in cases of aubacute cerebral ischemic stroke. The perfusion CT is useful in the assessment of acute stroke as an initial imaging modality.

  • PDF

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Experimental Studies on Extracorporeal Circulation by Sarns Heart-Lung Machine with Total Prime of Hartman's Solution (Sarns 심폐기의 혈희석 체외순환에 관한 실험적 연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.135-142
    • /
    • 1975
  • Total body perfusion using Sarns Heart-Lung-Machine, five head pump motor system with Travenol disposable bubble oxygenator was attempted in the dogs by the hemodilution method with total prime of buffered Hartman`s solution under moderate hypothermia. The first of all, the functions of Sarns Heart-Lung-Machine and effects of the hemodilution perfusion by buffered Hartman`s solution was studied. At the same time the changes of pressure of artery and vein, gas contents of the blood, and influence on the blood pictures were observed before, during, and after perfusion in 1-2 days. Hemodilution rates were the ranges of 85.0ml/kg to 97.3ml/kg and perfusion flow rates were maintained with the average 80. 5ml/kg/min [the ranges of 73.3ml/kg/min to 92.8ml/kg/min]. Hypothermia was employed between $35^{\circ}C$ and $31^{\circ} of the esophageal temperature. The total body perfusion was continued for 50-60 minutes. In the total cardiopulmonary bypass, atriotomy, ventriculotomy, and atrioventriculotomy were performed respectively. Arterial pressure was ranged approximately between 50 mmHg and 140 mmHg, but generally, it was maintained over 75 mmHg. Venous pressure was measured between 3.8 cm$H_2O$ and 16.0 cm$H_2O$. Optimum oxygenation could be achieved when oxygen flow into the oxygenator was maintained approximately at 5. 5L/min. In this way, the $pO_2$, $pCO_2$, and oxygen saturation were measured before, during, and afterperfusion in 1-2 days. The $pCO_2$ ranged approximately between 26.0 mmHg and 38.5 mmHg, but generally, it was maintained in the average 30.9-32.5mmHg. The $pO_2$ was ranged between 73.0mmHg and 332.2 mmHg, but it was maintained in the average 103.0-219.0 mmHg. Oxygen saturation was measured over 95. 0% during and after extracorporeal circulation respectively. Erythrocyte count, hemoglobin, hematocrit, and leucocyte count were decreased to 49.2%, 49.0%, 49.4%, and 21. 1% of the preoperative value during extracorporeal circulation respectively and these reductions were not recovered until 1-2 days after perfusion. These. resulted from relatively high degree of hemodilution rate and operative bleeding during these experimental studies. The platelets count was also decreased about to 71% during perfusion, on the contrary, it was increased progressively after perfusion and in 1-21 days after perfusion, the value was returned to preoperative contro1 level. Three dogs were all recovered after extracorporeal circulation.

  • PDF

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF