• 제목/요약/키워드: performance test

검색결과 21,709건 처리시간 0.047초

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

공공측량 성과심사에서 심사비율 개선을 위한 연구 (A Study on the Improvement of Sampling Rate of Performance Test in Public Survey)

  • 김규성;이영민;정병철;최윤수
    • Communications for Statistical Applications and Methods
    • /
    • 제17권6호
    • /
    • pp.853-863
    • /
    • 2010
  • 공공측량에서 성과 심사는 표본조사로 이루어지기 때문에 성과심사에서 심사비율은 매우 중요한 요인이다. 현행 성과심사 심사비율은 성과심사 제도 실시 초기에 경험적으로 결정되었기 때문에 이론적인 바탕이 부족하다는 지적과 함께 최근의 심사 여건에 맞도록 심사비율을 개선해야 한다는 의견이 제기되었다. 본 논문에서는 현재 우리나라에서 이루어지고 있는 공공측량 성과심사의 현황을 개략적으로 알아보고 현행 성과 심사 심사비율을 개선하기 위한 이론적 토대로서 성과심사 심사비율과 적합확률, 심사대상 수, 합격 비율의 관계를 살펴본다. 또한 성과심사 심사비율과 심사비용과의 관계를 토의한다.

발전설비의 성능진단 적용 무선계측 기술 (Wireless Measurement Technology for Power Plant Performance Diagnosis)

  • 김의환;이응곤;홍은기
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.9-16
    • /
    • 2017
  • The performance test is conducted for the purpose of determining the accurate thermal performance of the power generation facility or deriving the factors of thermal efficiency degradation. Compared to the acquisition method of power plant thermal performance test data by compensating cable or transmission cable, performance test using wireless instrument can acquire digital data in order to shorten the period due to installation and demolition of instrument and enhance safety of workers and relatively accurate data can be acquired thereby improving work efficiency. Wireless instruments have already been introduced to the market a long time ago, and some of them are used in industry such as petrochemical industry. However, there is no example which has been conducted for performance test of power generation facilities. In order to apply power generation facilities, a reliable system capable of acquiring performance data smoothly without affecting the control system is required. The wireless measurement system can eliminate the measurement defects and errors such as the damage due to the movement of the connecting cable, the extension due to the extension of the shield wire, the contact failure at the contact point between the measuring sensor and the connecting wire, This method has the advantage of collecting relatively accurate performance test data.

프로 골프선수의 TPI Level 1 Test Score에 따른 경기력 수준 분석 (Relationship Between Titleist Performance Institute Level 1 Test and the Performance of Professional Golf Players)

  • 김재은;도광선
    • 대한통합의학회지
    • /
    • 제10권2호
    • /
    • pp.27-35
    • /
    • 2022
  • Purpose : The purpose of this study is to analyze the correlation between the TPI Level 1 test and the performance of KPGA professional golf players. Methods : In 2019, 30 KPGA golf players attempted in the TPI Level 1 test. Their performance was then compared with the test based on the players' aggregated official records on the KPGA website, The most meaningful prize money ranking, average driving distance, fairway landing rate, and average number of putts were considered to evaluate their performance. Additionally, to obtain the average value of the players' accumulated records, the period from the first game in March 2019 to the end of October was considered. Results : The criterion for the difference between the upper group and the lower group was set based on the 9 points of the TPI Level 1 test, which showed the most significant difference. The prize money ranking stood at 63.00±51.77 in the upper group and 113.92±68.79 in the lower group in the TPI Level 1 test, the difference was significantly higher (p<.05) for the upper group (p<.05). The average driving distance was 286.15±10.06 yds for the upper group and 277.39±8.49 yds for the lower group, group, with the driving distance significantly higher in the upper group (p<.05). Further, the average number of putts for the upper group was 1.81±.02 and 1.85±.04 for the lower group, indicating a significant difference. Conclusion : A higher TPI Level 1 test score is likely to have a positive effect on performance.. As a result of the statistical values of this study, it was found that players must possess at least 9 out of 17 types of physical abilities Therefore, it can be considered that training and intervention to acquire these physical abilities are essential.

비행 전구간 유도제어 HILS 기법을 적용한 구동제어 알고리즘 성능 평가 연구 (Performance Evaluation for Several Control Algorithms of the Actuating System Using G/C HILS Technique)

  • 전완수;조현진;이만형
    • 한국정밀공학회지
    • /
    • 제13권9호
    • /
    • pp.114-129
    • /
    • 1996
  • This paper describes the whole development phase for the underwater vehicle actuating system with high hydroload torque disturbance. This includes requirement analysis, system modeling, control algorithm design, real time implementation, test and performance evaluations. As for driving control algorithms, fuzzy logic, variable structure and PD(Proportional-Differential) algorithm were designed and implemented on board controller using a single chip microprocessor. Intel 8797. And test and performance evaluation is carried out both single test and wystem integration test. We could confirm the basic performance of actuating system through the single test and gereral developing work of any actuating systems was finished with a single performance test of actuating system without system integration test. But, we suggested that system integration test be needed. System integration test is carried out using G/C HILS(Guidance and Control Hardware-In-the -Loop Simulation) which is constituted flight motion simulator, load simulator, real time host computer and the related subsystems such as inertial navigation system, power supply system and Guidance and Control Computer etc.. The most important practical contribution of this paper is that full system characteristics such as minimal control effort, enhancement of guidance and autopilot performance by the actuating system using G/C HILS technique are investigated. Through full running G/C HILS, in spite of the passing to single tests, some control algorithm resulted in failure as to stability of full system and system time frame.

  • PDF

수행평가의 실태와 문제점 탐색을 통한 근본적 대안 모색 (Exploring Fundamental Alternative through the Present Conditions and Problems of Performance Test)

  • 안효일
    • 수산해양교육연구
    • /
    • 제25권2호
    • /
    • pp.307-320
    • /
    • 2013
  • The purpose of this study is to inquire into present conditions and problems of current performance test and to try to come up with a fundamental alternative of it. Eventually, the studies of performance test so far can be labelled 'prescription' as a prospective approach. On the contrary, the fundamental alternative can be labelled 'understanding' as a retrospective approach. It can be seen that these 'prescription' and 'understanding' do not separate but represent both extreme ends of problem-solving.'Prescription' exists for 'understanding' and the latter can be acquired through the former. Just under this assumption, it can be accepted that 'prescription' as a prospective approach of performance test is an inevitable measure to achieve the purpose of it. However, the ultimate purpose of 'prescription' should proceed to 'understanding' as a retrospective approach.

철근콘크리트 기둥-철골 보 접합부의 용접성능 및 휨 저항성능 (Welding and Moment Resisting Performance of R/C Column-Steel Girder Connection)

  • 전재범;최광호;이세웅;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.553-558
    • /
    • 1999
  • As a process of development of composite beam-column connection system, structural tests have been conducted to verify moment resisting performance of the system. The tests have been proceeded by two steps, the first being welding performance test of the steel connection rod and stiffners, and the second overall moment resisting capacity of the fuly assembled system. Ten welding test specimens and four prototype specimens have been used in the test. Good structural performance of welding test specimens has been observed without any single welding failure, and sufficient moment resisting capacity has been proved from the overall performance test, with the moment magnitude in excess of the calculated plastic moment.

  • PDF

Performance Analysis of a Mixed-Flow Pump for Waterjet Propulsion

  • Ahn Jong-Woo;Kim Ki-Sup;Park Young-Ha;Kim Kyung-Youl;Oh Hyoung-Woo
    • Journal of Ship and Ocean Technology
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 2005
  • A mixed-flow pump is largely applied for waterjet propulsion in high-speed vessels because of excellent cavitation performance. For the present study, we analyze the performance of mixed-flow pump, which is composed of impeller and stator. The test device for a mixed-flow pump was installed in the test section in the KRISO cavitation tunnel. The performance tests of two mixed-flow pumps were carried out with the test device at various flow rates using various nozzles. The test results agree fairly well with the predicted results by commercial CFD code. The test device is available for verification of impeller performance together with CFD analysis

모델기반 시스템엔지니어링 접근을 통한 고속철도 성능시험 및 안전기준 요구사항 관리체계 구축 (Construct the requirement management system of the performance test and safety standard of the HSR using Model-Based Systems Engineering Approach)

  • 최요철;김찬묵;박철호;박영원;김연태;왕종배;김상암
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.174-179
    • /
    • 2004
  • To maintain design-knowledge database and manage configuration for requirement of performance test and safety standard of High Speed Railroad, It is established that managment system of performance test and safety standard and then constructed that design-knowledge database and documented a performance test and safety specification for supporting performance test and safety system using computer-aided tool.

  • PDF

PSD 설계를 위한 성능 시험장치 (Performance Test System for PSD Design)

  • 고광웅;이한주;정동운;이상용;오승협
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2003
  • In this Study, the types of PSD performance test systems were reviewed. And as a results of that reviewing process, a suitable PSD performance test system type for PSD design was proposed. PSD performance test systems can be classified with pulsating methods - the pulsating whole feeding system and the pulsating working fluid. The pulsating working fluid method can be re-classified with the devices of pulsating working fluid - a piston-type pulsator and a restrict-type pulsator. The pulsating-working-fluid performance test system with restrict-type pulsator was proposed to be a suitable type for identification of main-design-parameters.

  • PDF