• Title/Summary/Keyword: performance test

Search Result 21,626, Processing Time 0.06 seconds

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

Analysis of Four Pesticides, Isoproturon, Phenmedipham, Pyridate and Nitenpyram Residues by High-Performance Liquid Chromatography with Diode-Array Detector (HPLC를 이용한 Isoproturon, Phenmedipham, Pyridate 및 Nitenpyram 4종 성분의 잔류농약 분석법 개발)

  • Yang, Sung-Yong;Koo, Yun-Chang;Wang, Zeng;Heo, Kyeong;Kim, Hyeong-Kook;An, Eun-Mi;Shin, Han-Seung;Lee, Jin-Won;Lee, Kwang-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.8
    • /
    • pp.1165-1170
    • /
    • 2010
  • A method for the determination of four pesticide compounds, urea (isoproturon), bis-carbamate (phenmedipham), thiocarbamate (pyridate) and vinyllidenediamine (nitenpyram) were examined and analyzed by HPLC with C-18 column ($250\;mm{\times}4.6\;mm$, $5\;{\mu}m$ diameter particle size). Mobile phase consisted of deionized water, acetonitrile and 50 mM $KH_2PO_4$ (pH 2.5). Isoproturon and phenmedipham analytical condition was isocratic elution of the column with 50% solvent A (acetonitrile) and 50% solvent B (deionized water); pyridate was 85% solvent A (acetonitrile) and 15% solvent B (deionized water) at a flow rate of 1 mL/min; and nitenpyram analytical condition was 90% solvent A (50 mM $KH_2PO_4$, pH 2.5) and 10% solvent B (acetonitrile) at a flow rate of 1 mL/min. In results, retention times were 6.12, 8.63, 9.40 and 12.76 min for isoproturon, phenmedipham, pyridate and nitenpyram, respectively. All injection volumes were $10\;{\mu}L$ and the limit of quantitation was 0.05 mg/kg for four pesticide compounds, respectively. Recovery rate test was performed with three farm products, rice, apple and soybean. Four pesticide compounds were spiked at concentrations of 0.05, 0.1 and 0.5 mg/kg. The recovery rates were ranged from 70.18% to 118.08% and the standard deviations of all experiments were within 10%.

A Study on Utilization and Perceived Service Quality of the University Foodservice (대학급식 이용실태 및 급식서비스 품질이 고객만족과 고객태도에 미치는 영향)

  • Jung, Hyun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.4
    • /
    • pp.633-643
    • /
    • 2013
  • This study investigated the efficiency of university foodservice operations by analyzing the effect of consumer's perception towards university foodservice quality. University students in the Jeonnam area were surveyed and 571 out of 700 surveys were chosen (response rate: 97.0%). SPSS (ver. 20.0) was used to conduct descriptive analysis, factor analysis, reliability analysis, t-test, and multiple regression analysis. The results show that 21.9% of university students have never used the university foodservice, while 48.7% of university students have eaten there 1~2 times per week. The most common reasons reported for avoiding the university foodservice were a limited menu selection (51.5%) and an untasty food (45.8%). The perception of overall service quality at the university foodservice scored relatively low (3.01 points), compared with its importance (3.89 points). The food taste, menu variety, and quality of food ingredients are factors that require improvement for operational strategies by the importance-performance analysis (IPA). The food factors (taste, variety, and quality) among university foodservice qualities had a significantly positive effect on consumers' overall satisfaction (p<0.001), perceived value (p<0.01), intent to recommend (p<0.001), and intent to revisit (p<0.01). These result indicate that the university foodservice management should focus on developing food factors and strive to meet the needs of university students through continuous customer surveys.

Why Your Manuscripts Were Rejected or Required a Major Revision: An Analysis of Asia Pacific Journal if Information Systems (MIS 논문의 '게재 불가' 및 '수정 후 재심사' 사유: Asia Pacific Journal of Information Systems 심사소견서 분석)

  • Lee, Choong-C.;Yun, Hae-Jung;Hwang, Seong-Hoon
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.179-193
    • /
    • 2009
  • As the common saying attests, a publish-or-perish world, publishing is absolutely critical for academic researchers' successful careers. It is the most objectively-accepted academic performance criteria and the most viable way to attain public and academic recognition. Asia Pacific Journal of Information Systems(APJIS) has been recognized as the most influential domestic journal in Korean MIS field since July, 1991. Therefore, publishing in APJIS means your research is original, valid, and contributive. While most researchers learn how to publish an article in APJIS through a repetitive review process, thereby improving their chance of the' accepted' through their personal trial and error experiences, such valuable lessons and know-how tend to be kept personally and rarely shared. However, useful insights into research and publication skills could be also gained from sharing others' errors, neglect, and misjudgments which are equally critical in improving researchers' knowledge in the field (Murthy and Wiggins, 2002). For this reason, other academic disciplines make systematic efforts to examine the paper review process of major journals and share the findings from these studies with the rest of the research community members (Beyer et al., 1995; Cummings et al, 1985; Daft, 1995; Jauch and Wall, 1989; Murthy and Wiggins, 2002). Recognizing the urgent need to provide such type of information to MIS research community in Korea, we have chosen the most influential academic journal, APJIS with an intention to share the answer to the following research question: "What are the common problems found in the manuscripts either 'rejected' or 'required a major revision' by APJIS reviewers?" This study analyzes the review results of manuscripts submitted to APJIS (from January, 2006 to October, 2008), particularly those that were 'rejected' or required a 'major revision' at the first round. Based on Daft's(1995) study, twelve most-likelihood problems were defined and used to analyze the reviews. The twelve criteria for classification, or "twelve problems", are as follows: No theory, Concepts and operationalization not in alignment, Insufficient definition--theory, Insufficient rationale--design, Macrostructure--organization and flow, Amateur style and tone, Inadequate research design, Not relevant to the field, Overengineering, Conclusions not in alignment, Cutting up the data, and Poor editorial practice. Upon the approval of the editorial board of APJIS, the total 252 reviews, including 11 cases of 2005 and 241 cases from July, 2006 to October, 2008, were received without any information about manuscripts, authors, or reviewers. Eleven cases of 2005 were used in the pilot test because the data of 2005 were not in complete enumeration, and the 241 reviews (113 cases of 'rejection' and 128 ones of 'major revision') of 2006, 2007, and 2008 were examined in this study. Our findings show that insufficient rationale-design(20.25%), no theory(18.45%), and insufficient definition--theory(15.69%) were the three leading reasons of 'rejection' and 'major revision.' Between these two results, the former followed the same order of three major reasons as an overall analysis (insufficient rationale-design, no theory, and insufficient definition-theory), but the latter followed the order of insufficient rationale--design, insufficient definition--theory, and no theory. Using Daft's three major skills-- 'theory skills', 'design skills', and 'communication skills'-- twelve criteria were reclassified into 'theory problems', 'design problems', and 'communication problems' to derive more practical implications of our findings. Our findings show that 'theory problems' occupied 43.48%, 'design problems' were 30.86%, and 'communication problems' were 25.86%. In general, the APJIS reviewers weigh each of these three problem areas almost equally. Comparing to other disciplines like management field shown in Daft's study, the portion of 'design problems' and 'communication problems' are much higher in manuscripts submitted to the APJIS than in those of Administrative Science Quarterly and Academy of Management Journal even though 'theory problems' are the most predominant in both disciplines.

The Relationship Between Perception of Prosody, Pitch Discrimination, and Melodic Contour Identification in Cochlear Implants Recipients (인공와우이식 난청인의 말소리 운율변화에 따른 구어 이해와 음도 변별, 선율윤곽 확인 간 관련성)

  • Kim, Eun Yeon;Moon, Il Joon;Cho, Yang-sun;Chung, Won-ho;Hong, Sung Hwa
    • Journal of Music and Human Behavior
    • /
    • v.14 no.2
    • /
    • pp.1-18
    • /
    • 2017
  • The relationships between the ability to understand changes in meaning depending on the prosody of spoken words and the ability to perceive pitch and melodic contour in cochlear implants (CI) recipients were examined. Fifteen postlingual CI recipients were measured in terms of speech prosody perception, speech perception, pitch discrimination (PD), and melody contour identification (MCI). The speech prosody perception test consists of words with positive (PW) and neutral meaning (NW). Participants were asked to identify the meaning of words depending on the conditions of positive and negative prosody. The MCI consists of subtests 1 and 2 with different chance levels to choose. Then, the relationships between speech prosody perception, speech perception, PD, and MCI performance were analyzed. There was a significant difference in identifying the meaning of words expressed in a different prosody between the PW and NW conditions. Speech prosody perception showed a significant correlation with MCI 1 while there was no significant relationship with speech perception. Although speech perception may be possible after CI, limited spoken word comprehension due to decreased sensitivity for prosodic changes may persist in CI recipients. In addition, there was a limitation in perception of melodic contour change compared to pitch discrimination, which is related to speech prosody perception.

Utility of polymerase chain reaction(PCR) according to sampling time in CSF and stool specimens from patient with aseptic meningitis (무균성 뇌막염 환자에서 뇌척수액과 대변 채취 시점에 따른 PCR의 유용성)

  • Kim, Myo Jing;Lee, Hye Jin;Choi, Jung Mi;Jung, Soo Jin;Huh, Jae Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.745-750
    • /
    • 2006
  • Purpose : Enteroviruses are the most common cause of aseptic meningitis in patients of all ages. A definite diagnosis of enteroviral meningitis can be established by detection of virus directly in CSF specimens. But this is time-consuming and lacks sensitivity, so polymerase chain reaction(PCR) detecting of viral RNA in patient specimens such as CSF, stool has been demonstrated. But little is known about the influence of sampling time on the results of CSF PCR and stool PCR. We investigated diagnostic utility of PCR of CSF and stool according to sampling time after the onset of symptoms. Methods : PCR results were analyzed according to sampling time for 42 patients diagnosed aseptic meningits in our hospital from $11^{th}$ January to $30^{th}$ August, 2005. Results : The diagnostic yield of the test was higher of CSF specimens obtained ${\leq_-}2$ days after clinical onset(positive PCR results 9/18, 50 percent), compared with CSF collected >2 days after onset(positive PCR results 1/24, 4.2 percent)(P=0.001). Instead, positive PCR results of fecal specimens maintained highly(average 90.5 percent), 10 cases had also positive PCR results even 5-6 days after onset. 10 cases of CSF specimens had positive enterovirus PCR results containing coxsackievirus B5 (n=6), coxsackievirus B3(n=3). 38 cases of stool specimens had positive enterovirus PCR results containing echovirus 18(n=7), echovirus 9(n=3), coxsackievirus B5(n=8), coxsackievirus B3(n=3). 6 cases(coxackie B5) had positive CSF PCR and stool PCR, both. Conclusion : Stool PCR was clinically sensitive for detecting enterovirus during enteroviral meningits and could give a presumptive diagnosis throughout the disease course. A definite diagnosis was obtained by CSF PCR, but its utility was clearly lower for samples obtained >2 days after clinical onset. Therefore, it is recommended that, in addition to performance of CSF PCR, fecal samples obtained from patients with suspected enteroviral meningitis should be tested by PCR, especially when the duration of symptoms is >2 days.