Design of Various WBAN Antennas Considering for the Location on a Human Body (인체 상 위치를 고려한 다양한 WBAN 안테나 설계)

  • Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1095-1103
    • /
    • 2014
  • WBAN has received great attention recently due to its versatile applicability. In this paper, antennas suitable for WBAN communication depending on the locations of mobile devices and the manufacturing of a human equivalent phantom are introduced. The effect of the body on the communication performance is largely dependent on the locations of devices. Specifically, the radiation and return loss characteristics of the antenna are greatly influenced by the characteristics of a medium existing in the near-field of an antenna. Thus, the proper WBAN antenna design is important in establishing a successful communication link between the transceivers. To consider the effect of the body on the antenna performance, the human equivalent phantom is also important factor in the WBAN antenna design and measurement. In introduction, categorization of the WBAN communication channel is introduced and antenna characteristics required for each communication channel are described. In the main subject section, several WBAN antenna design examples along with the implementation of the human equivalent phantom are discussed. In conclusion, the factors, which have to be considered in the design process, and future research are mentioned.

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

Development of Laser Induced Real Time Photoacoustic Tomography Imaging System and Phantom Evaluation (레이저 유도방식의 실시간 광음향 단층영상 기술 개발과 팬텀이미지 평가)

  • Ryu, Sang-Hun;Shin, Dong-Ho;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.879-884
    • /
    • 2012
  • Photoacoustic Tomography (PAT) is a promising medical imaging modality by reason of its particularity. It combines optical imaging contrast of optical imaging with the spatial resolution of ultrasound imaging and can demonstrate change of biological feature in an image. For that reason, many studies are in progress to apply this technic for diagnosis. But, real-time PAT system is necessary to confirm a biological reaction induced by external stimulation immediately. Thus, we developed a real-time PAT system using linear array transducer and self-developed Data acquisition board (DAQ) resources, To evaluate the feasibility and performance of our proposed system, two type of phantom test were also performed. As a result of those experiments, the proposed system shows enough performance and confirm its usefulness.

A Performance Enhancement of Osteoporosis Classification in CT images (CT 영상에서 골다공증 판별 방법의 성능 향상)

  • Jung, Sung-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1248-1259
    • /
    • 2016
  • Classification methods based on dual energy X-ray absorptiometry, ultrasonic waves, and quantitative computed tomography have been proposed. Also, a classification method based on machine learning with bone mineral density and structural indicators extracted from the CT images has been proposed. We propose a method which enhances the performance of existing classification method based on bone mineral density and structural indicators by extending structural indicators and using principal component analysis. Experimental result shows that the proposed method in this paper improves the correctness of osteoporosis classification 2.8% with extended structural indicators only and 4.8% with both extended structural indicators and principal component analysis. In addition, this paper proposes a method of automatic phantom analysis needed to convert the CT values to BMD values. While existing method requires manual operation to mark the bone region within the phantom, the proposed method detects the bone region automatically by detecting circles in the CT image. The proposed method and the existing method gave the same conversion formula for converting CT value to bone mineral density.

Respiratory Motion Correction on PET Images Based on 3D Convolutional Neural Network

  • Hou, Yibo;He, Jianfeng;She, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2191-2208
    • /
    • 2022
  • Motion blur in PET (Positron emission tomography) images induced by respiratory motion will reduce the quality of imaging. Although exiting methods have positive performance for respiratory motion correction in medical practice, there are still many aspects that can be improved. In this paper, an improved 3D unsupervised framework, Res-Voxel based on U-Net network was proposed for the motion correction. The Res-Voxel with multiple residual structure may improve the ability of predicting deformation field, and use a smaller convolution kernel to reduce the parameters of the model and decrease the amount of computation required. The proposed is tested on the simulated PET imaging data and the clinical data. Experimental results demonstrate that the proposed achieved Dice indices 93.81%, 81.75% and 75.10% on the simulated geometric phantom data, voxel phantom data and the clinical data respectively. It is demonstrated that the proposed method can improve the registration and correction performance of PET image.

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

Development of BMD Phantom using 3D Printing (3D 프린팅을 이용한 골밀도 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Hong, Sung-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.185-192
    • /
    • 2019
  • DXA is the most commonly used BMD examination equipment with the best performance on reflecting the biological alteration with tiny change of bone density. In spite of the importance of the quality control to maintain the accuracy and precision of the examination, considerable number of hospitals are not conducting QC due to the difficulty and high cost of the phantom product. This study develops the cross revision phantom with 3D printer and the change of the degree of infilling filaments which can be readily secured, and provides the usefulness assessment of the developed phantom by comparing with existing products. The Hounsfield Units of ABS, TPU, PLA, 30% Cu-PLA, and 30% Al-PLA are assessed. The Hounsfield Units result at infilling rate 100% was $-149.74{\pm}2.36$, $-55.62{\pm}7.14$, $-7.68{\pm}3.82$, $87.53{\pm}1.07$, and $1795.20{\pm}16.15$. The L1, L2, L3 BMD of 3D printing phantom with linear regression model were $0.620{\pm}0.010g/cm^2$, $1.092{\pm}0.025g/cm^2$, $1.554{\pm}0.026g/cm^2$ which are statistically relevant to the existing phantom products. This result provides the base line data for various medical phantom produce and capability of proper quality control of DXA equipment.

Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT (PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.