• Title/Summary/Keyword: performance differences

Search Result 4,478, Processing Time 0.034 seconds

Antioxidants in Serum and Induced Sputum of COPD Patients (만성폐쇄성폐질환 환자의 혈청 및 유도객담에서의 항산화제)

  • Park, Hyeon-Kwan;Yu, Young-Kwon;Kim, Kyu-Sik;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.158-170
    • /
    • 2001
  • Background : Although an oxidants and antioxidants imbalance has been considered in the pathogenesis of chronic obstructive pulmonary disease (COPD), there is a paucity of reports focussing on the smoking-induced changes of oxidants and antioxidants in COPD. Method : The concentration of antioxidants (ascorbic acid, uric acid, retinol, and $\alpha$- & $\gamma$-tocopherol) was measured in the serum and induced sputum of 30 healthy controls and 34 stable COPD patients using high performance liquid chromatography (HPLC). The inhibition of lipid peroxidation as an index of antioxidant capacity was measured in the serum by a TBA assay. Results : The serum concentration of ascorbic acid, $\alpha$-tocopherol, and retinol were significantly lower in the patients with COPD than in healthy controls ($484.8{\pm}473.3$ vs $1497.8{\pm}819.2\;pmol/L$, $48.38{\pm}17.34$ vs $73.96{\pm}26.29\;pmol/L$, p<0.001, and $9.51{\pm}8.33$ vs $15.01{\pm}5.88\;pmol/L$, p<0.05, respectively, mean$\pm$SD). However, there were little differences in the ascorbic acid and uric acid concentrations in the induced sputum between the COPD patients and the controls. The induced sputum to serum ratio of ascorbic acid was significantly higher in COPD patients compared with healthy control (0.375 vs 0.085, p<0.05). In the normal controls, the serum ascorbic acid concentration was lower in smokers than in nonsmokers ($1073{\pm}536$ vs $1757{\pm}845\;pmol/L$, p<0.05), but the level was still higher than that of the COPD patients (p<0.05). The serum retinol levels were correlated with $FEV_1$ in COPD patients (r=0.58, p<0.05). The products of lipid peroxidation were increased in normal smokers and COPD compared with norma1 nonsmokers ($115.56{\pm}19.93$ vs $120.02{\pm}24.56$ vs $91.87{\pm}20.71\;{\mu}mol/{\mu}mol$ Pi of liposome, p<0.05). Conclusion : Cigarette smoking may induce the dep1etion of serum antioxidants and this depletion of antioxidants is suggested to play a role in the pathogenesis of COPD.

  • PDF

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).

Productivity of Lespedeza Species by the Number of Cutting Times (싸리류(類)의 예확회수별(刈穫回數別) 생산성(生産性)에 관(關)한 연구(硏究))

  • Han, Young Chang
    • Journal of Korean Society of Forest Science
    • /
    • v.23 no.1
    • /
    • pp.17-27
    • /
    • 1974
  • In order to investigate the variation of nutritive value, fertilizer value, productivity and growth performance by the number of cutting times in Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonica var. intermedia, the plots of one, two and four cutting times in a year had been made through 1972 to 1973. The results are summarized as follows. 1. Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonicavar. var. intermedia showed increase of growth and productivity in two plots excluding the plots of four time cuttings. 2. Significant differences at 1% level were shown among the species and the number of cutting times in total grass yield. Lespedeza bicolor showed the greatest production, and followed by Lespedeza maximowiczii and Lespedeza japonica var. intermedia. The plots of one cutting time a year produced more dry weight than that of two and four cutting times. The production in plots of fourth cutting showed less growth and yield. 3. The ratios of dry weight to fresh weight and of leaf weight to stem weight were decreased when the number of cutting times increased in Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonica var. intermedia. 4. Crude protein was decreased, though crude fiber content was increased when the grasses were growing more and more. Conent of crude fat showed great variation by the number of cutting times and cutting period seoson. 5. Early cut tings of Lespedeza showed higer fertizer value than late cuttings in all the species. 6. It is suggested that two and three time cutting through a year in Lespedeza bicolor and Lespedeza japonica var. intermedia having high nutritive and fertilizer value is good when using the Lespedeza species as a fodder or manuers, and one time cutting a year will be good when using the Lespedeza species as a fuel.

  • PDF

Effects of Various Diets on Growth and Body Composition of Juvenile Parrot Fish, Oplegnathus fasciatus (먹이 종류가 돌돔 Oplegnathus fasciatus 치어의 성장 및 체성분에 미치는 영향)

  • Moon Lee, HaeYoung;Nam, Myung-Mo
    • Korean Journal of Ichthyology
    • /
    • v.27 no.4
    • /
    • pp.293-299
    • /
    • 2015
  • The feeding experiment was conducted to investigate the effects of one experimental diet (EDP) and five different commercial diets (CEPs) on growth and body composition for juvenile parrot fish, Oplegnathus fasciatus. An EDP was formulated to contain 50% crude protein (CP) from fishmeal, casein, zein and wheat flour and 15% crude lipid (CL) from squid liver oil. Five CEPs for seawater fish were two domestic E commercial diet (DECD) and C commercial diet (DCCD), three imported H commercial diet (IHCD), L commercial diet (ILCD) and O commercial diet (IOCD) containing 53.1~66.6% CP and 10.7~14.6% CL, respectively. Each diet was fed to triplicate groups of juvenile parrot fish initially weighing $1.14{\pm}.01g/fish$ (mean${\pm}$SD) in a flow-through seawater system with a water temperature of $19.0{\sim}25.0^{\circ}C$. Weight gain (WG) and feed efficiency (FE) were significantly greatest in fish fed the DCCD and IOCD; intermediate responses were observed for fish fed the ILCD, while the IECD, IHCD, and the EDP produced the lowest WG and FE values. Survival with no significant difference approached 100% for fish fed the all six diets in this experiment. Whole-body moisture, protein, lipid and ash contents were not affected by the different type of diets. Therefore, type of diets appeared to be important factor in influencing WG and FE of juvenile parrot fish; the best diets for juvenile parrot fish was determined to be the domestic commercial C and the imported commercial O diets containing high protein (61.3, 66.6%) and lipid (14.6, 13.0%) in natural seawater based on highest WG, and FE, respectively. This study indicates that the two commercially formulated diets containing two highest proteins and lipids used in this experiment could be practical diets for juvenile parrot fish; these differences of growth performance between experimental diet and commercial diets may be reason for different dietary protein and lipid levels.

High VPP Combination Chemotherapy for Advanced Non-Small Cell Lung Cancer (진행된 비소세포 폐암에 대한 High-VPP 복합화학요법의 효과)

  • Hong, Seok-Cheol;Han, Pyo-Seong;Lee, Jong-Jin;Cho, Hai-Jeong;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.367-377
    • /
    • 1993
  • Background: The benefits of combination chemotherapy in unresectable non-small cell lung cancer remain uncertain. But, according to the recent reports, the response rates of cisplatin-based polychemotherapy regimens are higher than those of single agent. Also, the response rates of high-dose cisplatin group are higher than those of low-dose cisplatin group. In attemp to answer the question whether treatments, combination chemotherapy (high VPP) and combination chemotherapy with radiation therapy, improve survival in advanced non-small cell lung cancer, we begin to study. Method: Thirty-five patients above stage III, diagnosed histologically as non-small cell lung cancer, were enrolled. Among them, nineteen received a combination chemotherapy consisting of VP-16 & high-dose cisplatin (100 $mg/m^2$) and/or radiation therapy. The other group (16 subjects) received no therapy. To investigate the differences of survival and response rates between two groups and the side effects related to therapy, we reviewed patients' records. Results: 1) The overall objective response rate was 47%(9/19) with one complete remission. 2) In patients who received polychemotherapy and radiation therapy, the response rate was 60%(6/10) with one complete remission and survival rates of 3 months, 6 months and 12 months were 100%, 70% and 40%. 3) In patients who received polychemotherapy, the response rate was 33% (3/9) with no complete remission and survival rates of 3 months, 6 months and 12 months were 78%, 67% and 33%. 4) Overall, treated patients survived significantly longer (p<0.05) than non-treated patients (median survival 307 days versus 95 days). 5) Analysis of the various prognostic factors disclosed that good performance status, stage III and squamous cell type showed the good response rates. 6) The toxicities were nausea and/or vomiting (100%), alopecia (90%), anemia (79%), leukopenia (69%), thrombocytopenia (2%), increased creatinine (16%) and neurotoxicity (5%). Conclusion: According to above results, there are relatively good results that high VPP combination chemotherapy in advanced non-small cell lung cancer improves survival in the treated group than in the non-treated group. Thus, it is considerd that we select the patients with proper indications and treat them with effective chemotherpy and radiation therapy. But, because improvement related to high VPP ploychemotherapy is not marked in this study, it is necessary that we should investigate follow-up studies in many cases.

  • PDF

Applicability of American and European Spirometry Repeatability Criteria to Korean Adults (한국 성인을 대상으로 한 미국 및 유럽 폐활량 검사 재현성 기준의 유용성)

  • Park, Byung Hoon;Park, Moo Suk;Jung, Woo Young;Byun, Min Kwang;Park, Seon Cheol;Shin, Sang Yun;Jeon, Han Ho;Jung, Kyung Soo;Moon, Ji Ae;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Ahn, Song Vogue;Oh, Yeon-Mok;Lee, Sang Do;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.405-411
    • /
    • 2007
  • Background: The objective of this study was to evaluate the clinical applicability of the repeatability criteria recommended by the American Thoracic Society/European Respiratory Society (ATS/ERS) spirometry guidelines and to determine which factors affect the repeatability of spirometry in Korean adults. Methods: We reviewed the spirometry data of 4,663 Korean adults from the Korean National Health and Nutritional Examination Survey (KNHANES) Chronic Obstructive Pulmonary Disease Cohort (COPD cohort) and the Community-based Cohort Study VI-Fishing village/Islands (community cohort). We measured the anthropometric factors and differences between the highest and second-highest FVC (dFVC) and $FEV_1$ ($dFEV_1$) from prebronchodilator spirometry. Analyses included the distribution of dFVC and $dFEV_1$, comparison of the values meeting the 1994 ATS repeatability criteria with the values meeting the 2005 ATS/ERS repeatability criteria, and the performance of linear regression for evaluating the influence of subject characteristics and the change of criteria on the spiro-metric variability. Results: About 95% of subjects were able to reproduce FVC and $FEV_1$ within 150 ml. The KNHANES based on the 1994 ATS guidelines showed poorer repeatability than the COPD cohort and community cohort based on the 2005 ATS/ERS guidelines. Demographic and anthropometric factors had little effect on repeatability, explaining only 0.5 to 3%. Conclusion: We conclude that the new spirometry repeatability criteria recommended by the 2005 ATS/ERS guidelines is also applicable to Korean adults. The repeatability of spirometry depends little on individual characteristics when an experienced technician performs testing. Therefore, we suggest that sustained efforts for public awareness of new repeatability criteria, quality control of spirograms, and education of personnel are needed for reliable spirometric results.

Comparison of Thatch Accumulation in Warm-Season and Cool-Season Turfgrasses under USGA and Mono-layer Soil Systems (USGA 지반 및 약식지반에서 난지형과 한지형 잔디의 대취축적 비교)

  • Kim, Kyoung-Nam;Kim, Byoung-Jun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.129-136
    • /
    • 2010
  • This study was initiated to investigate thatch accumulation in several turfgrasses grown under two soil systems. The 45 centimeter deep USGA system was constructed with rootzone, intermediate and drainage layers. The mono-layer system, however, was made with only a 30cm rootzone layer. Turfgrasses used in the study were comprised of 3 varieties from Korean lawngrass of Warm-Season Grass(WSG) and 3 blends and 3 mixtures from Cool-Season Grass(CSG). A total of 9 turfgrass treatments were replicated three times in RCBD in both systems. Cultural practices for the research plot followed a typical maintenance program for highly managed turf. Treatment differences for thatch accumulation were observed among the turfgrasses in both soil systems. Thatch under the USGA system was 9% greater than under the mono-layer system due to its more favorable conditions for turf growth. Higher thatch depth was found with Korean lawngrass, 34~87% in the USGA system and 16~75% in the mono-layer system when compared with CSG. Among WSG, the Joongji variety was the highest in thatch layer under both the USGA and mono-layer systems. Kentucky bluegrass(KB) was the greatest among CSG, since it is a rhizomatous-type in growth habit, resulting in faster production of organic matter over bunch-type of tall fescue and perennial ryegrass. Proper depth in the thatch layer was known to be beneficial by enhancing the resiliency and wear tolerance of the turf in athletic fields. Thus, KB was considered to be a very excellent turfgrass in terms of turf quality, environmental performance, physical properties and soccer player safety. However, disadvantages such as poor water-holding properties, more inclined to injury from environmental stresses and severe diseases and insect injury were also expected where thatch was excessively accumulated. Therefore, these results demonstrate that more frequent measures for controlling thatch such as vertical mowing, topdressing or coring should be employed for soccer fields with Korean lawngrass and KB over other turfgrasses.

Study on Operating Strategy for Recreation Forests through Comparing the Level of User Satisfaction according to Clusters (군집별 만족도 비교를 통한 자연휴양림의 효율적 운영 방안 연구)

  • Gang, Kee-Rae;Lee, Kee-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.39-48
    • /
    • 2010
  • Recreation forests are in the spotlight as the place for personality development, mind and body comfort, companionship, and environment education in forests and valleys. Visitors to recreation forests have been on the increase along with booming in recreation forest building since 1988. Recreation forests are being categorized according to some features such as regional and environmental condition. Recreation forests, however, have not met the expectations of some visitors who want to take a rest with calmness due to the influence of the 5-day-work-week system, increasing interest in rest, leisure, and well-being, and users converge during weekends, summer, and the tourist season. In order to improve visitors' satisfaction efficiently, this study surveyed the level of satisfaction in each cluster based on the precedent study which had classified 85 national or public recreation forests in Korea into clusters. Questionnaires were distributed properly to each cluster and, of the 1,132 questionnaires collected, 1,015 were valid and used for analysis. Reliability of questionnaires and statistical validity of the model were verified. As a result, there are meaningful differences in the ranking of independent variables which affect the level of satisfaction according to clusters. Variables in rest and fatigue recovery have the strongest influence on the level of satisfaction in the clusters of potential factor, internal activation factor, and mixed potential capacity factor. In the use performance and visiting condition factor cluster, appropriateness of visit cost is most influential and, in the education cluster, connectivity with tourist attractions around it is most affective. These results can provide priority in services and maintenance of recreation forests for improving the level of satisfaction and differentiate the distribution of resources according to clusters.