• Title/Summary/Keyword: per-cooling

Search Result 248, Processing Time 0.026 seconds

Study on Heat Treatment of Red Pine Log (소나무 원목의 열처리에 관한 연구)

  • Eom, Chang-Deuk;Han, Yeonjung;Shin, Sang Chul;Chung, Yeong Jin;Jung, Chan Sik;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.50-56
    • /
    • 2007
  • FAO standard for heat sterilization of wood, International standards for phytosanitary measures (ISPM) No.15, must meet heat-treated wood core temperature to be higher than $56^{\circ}C$ and keep the temperature for more than 30 minutes. This study was carried out to analyze the heat treatment characteristics of domestic pinewood sterilized with the FAO standard. To enhance the effectiveness of heat treatment process in mountainous district energy consumption and time required to reach target temperature were evaluated at various temperature and relative humidity conditions and moisture contents of wood. Heat-treatment of high temperature and high humidity reduced the required heating time. Lower humidity levels at same temperature reduced energy consumption per unit time. However, lower humidity levels could not reduce total energy consumption greatly because longer treatment time was required at that condition. It is necessary to estimate energy consumption and predict treatment time in dynamic heating and cooling situations, because it frequently happens not to meet optimum treatment condition due to poor surrounding climates and operation performance of heat treatment facility in real field.

Stable Isotope and Fluid Inclusion Studies of Gold-Silver-Bearing Hyarothermal-Vein Deposits, Cheonan-Cheongyang-Nonsan Mining District, Republic of Korea: Cheongyang Area (한반도 천안-청양-논산지역 광화대내 금-은 열수광상의 안정동위원소 및 유체포유물 연구 : 청양지역)

  • So, Chil-Sup;Shelton, K.L.;Chi, Se-Jung;Choi, Sang-Hoon
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.149-164
    • /
    • 1988
  • Electrum-sulfide mineralization of the Samgwang and Sobo mines of the Cheongyang Au-Ag area was deposited in two stages of quartz and calcite veins that fill fault zones in granite gneiss. Radiometric dating indicates that mineralization is Early Cretaceous age (127 Ma). Fluid inclusion and sulfur isotope data show that ore mineralization was deposited at temperatures between $340^{\circ}$ and $180^{\circ}C$ from fluids with salinities of 1 to 8 wt. % equiv. NaCl and a ${\delta}^{34}S_{{\sum}S}$ value of 2 to 5 per mil. Evidence of fluid boiling (and $CO_2$ effervescence) indicates a range of pressures from < 200 to $\approx$ 700 bars, corresponding to depths of ${\approx}1.5{\pm}0.3\;km$ in a hydrothermal system which alternated from lithostatic toward hydrostatic conditions. Au-Ag deposition was likely a result of boiling coupled with cooling. Meaured and calculated hydrogen and oxygen isotope values of ore-forming fluids indicate a significant meteoric water component, approaching unexchanged paleometeoric water values. Comparison of these values with those of other Korean Au-Ag deposits reveals a relationship among depth, Au/Ag ratio and degree of water-rock interaction. All investigated Korean Jurassic and Cretaceous gold-silver-bearing deposits have fluids which are dominantly evolved meteoric waters, but only deeper systems (${\geq}1.5\;km$) are exclusively gold-rich.

  • PDF

Cold Surges over Korean Peninsula Associated with Arctic Oscillation and the Role of Heat Source (극 진동에 연관된 한반도 한파와 열원의 역할)

  • Shin, Sung-Chul;Kim, Maeng-Ki;Lee, Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.27 no.3
    • /
    • pp.302-312
    • /
    • 2006
  • This study has investigated the effect of Arctic Oscillation (AO) on cold surge through atmospheric circulation and heat source analysis for the past winters from 1979 to 2004. The number of occurrence of cold surge in the negative AO phase is about 14.3% larger than that in the positive AO phase. The number of occurrence of cold surge per a month in the negative (positive) AO phase is about 1.33 (1.05), respectively, indicating that the negative AO phase has about 26.6% larger occurrence than the positive AO phase. It means that the cold surge has occurred frequently in particular months with the negative AO phase. And it also shows that surface temperature in the negative AO phase is about $0.6^{\circ}C$ lower than in positive AO phase. As a result of the analysis for the difference of heat source according to the intensity of AO, it shows that surface air temperature around the Korean peninsula in the negative AO phase is more lower than in positive AO phase by the intensification of cold advection term. However, heat source term cancels out the cooling effect by cold advection term, indicating that it suppresses the decrease in surface air temperature. It results in a small difference of $0.6^{\circ}C$ in surface air temperature between the positive and negative AO phase in spite of the significance of atmospheric circulation change.

EFFECTS OF EUGENOL, CAPSAICIN AND DEMETHOXY-NE ON THE PAIN RESPONSE OF DENTAL PULP (Eugenol, Capsaicin과 Demethoxy - NE가 치수동통 반응에 미치는 영향)

  • Lee, Eun-Goo;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.10-21
    • /
    • 1992
  • The purpose of this study was to investigate the analgesic effect of eugenol, capsaicin and demethoxy-NE. Young adult cats, weighing 2.0 to 3.0kg, were used. Each animal was anesthetized (${\alpha}$-chloralose 60mg per kg body weight) and divided into four groups; control, eugenol, capsaicin and demethoxy-NE group. The anterior digastric muscles were exposed and a pair of electrodes was inserted to record the electromyograms. To expose the pulp, each canine teeth was prepared with a low speed bur under cooling and used for recording anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp. To observe effects on jaw opening reflex, inferior alveolar nerve of both sides were exposed for drug application and wire electrodes were inserted in anterior digstric muscle for recording the EMGs. To observe effects on action potential, saphenous nerves of both sides were exposed and three tissue pools were made from surrounding tissue. The most distal pool was used for applying stimulation, the most proximal one for recording of action potential, and the other one for drug application. One side of inferior alveolar nerve and saphenous nerve were used for eugenol, capsaicin, or demethoxy-NE application, the other side of nerve for control experiments(only vehicle application). Anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp were recorded before drug application, immediate after drug application, at 60 and 120 minutes, and 5 days after drug application. Action potentials were recorded before drug application, immediate after 30 minutes drug application, at 30, 60 and 120 minutes after drug had been washed out. The results were as follows; 1. Eugenol had a continuous blocking effect on the anterior digastric muscular EMGs evoked by noxious pulp stimulation and after 5 days, showed completely blocking effect. 2. After 5 days, demethoxy-NE applied to dental pulp had a considerable blocking effect on the jaw opening retlex evoked by noxious stimulation but capsaicin had no significant effect. 3. After 5 days, eugenol group showed the strongest blocking effect among the all experimental groups on the jaw opening reflex evoked by noxious stimulation of dental pulp and capsaicin group showed the weakest blocking effect. 4. Eugenol had a completely blocking effect on the action potential conductivity of peripheral nerve. Capsaicin and demethoxy-NE had the blocking effect on the action potential conductivity of ${\alpha}$-and C-nerve fibers. 5. Capsaicin, demethoxy-NE and eugenol applied to inferior alveolar nerve surppressed the jaw opening reflex evoked by noxious stimulation of dental pulp.

  • PDF

Insulation Properties and Evaluation of Diglycerol Ester Synthesized by Solid Acid Catalysts (고체산 촉매를 이용해 합성한 diglycerol ester의 전기절연 특성 및 평가)

  • Gwon, Miseong;Baek, Jae Ho;Kim, Myung Hwan;Park, Dae-Won;Lee, Man Sig
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.254-261
    • /
    • 2014
  • The transformer is a static electrical device that transfers energy by inductive coupling. Then, heat is occurred at coils, inner transformer was filled with insulating oils for cooling and insulation. Although mineral oil as insulating oil has been widely used, it does not meet health and current environmental laws because it is not biodegradable. Therefore, in this study, the diglycerol ester was synthesized with diglycerol and fatty acids (oleic acid and caprylic acid) over various catalysts for insulating oil having biodegradability, high flash points and low pour points. The sulfated zirconia ($SO_4{^{2-}}/ZrO_2$) catalyst prepared at different calcination temperature shows the highest conversion of fatty acids at $600^{\circ}C$ due to crystallinity and high density of acid sites per surface area. When the molar ratio of oleic acid and caprylic acid is 1:3, the diglycerol ester shows superior insulation properties that are the flash point of $306^{\circ}C$ and pour point of $-50^{\circ}C$. The insulation properties of synthesized diglycerol ester shows the pour point of $-50^{\circ}C$ and the flash point of over $300^{\circ}C$. Therefore, diglycerol ester is superior to the vegetable oils in insulation properties.

Crystal Structure of Xenon Encapsulate within Na-A Zeolite

  • Im, U Taek;Park, Man;Heo, Nam Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.75-80
    • /
    • 2000
  • The positions of Xe atoms encapsulated in the molecular-dimensioned cavities of fully dehydrated Na-A have been determined. Na-A was exposed to 1050atm of xenon gas at 400 $^{\circ}C$ for seven days, followed by cooling at pressure to encapsulate Xe atoms. The resulting crystal structure of Na-A(7Xe) (a = 12.249(1) $\AA$, $R_1$ = 0.065, and $R_2$ = 0.066) were determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at 21(1) $^{\circ}C$ and 1 atm. In the crystal structure of Na-A(7Xe), seven Xe atoms per unit cell are distributed over four crystallographically distinct positions: one Xe atom at Xe(1) lies at the center of the sodalite unit, two Xe atoms at Xe(4) are found opposite four-rings in the large cavity, and four Xe atoms, two at Xe(2) and others at Xe(3), respectively, occupy positions opposite and between eight- and six-rings in the large cavity. Relatively strong interactions of Xe atoms at Xe(2) and Xe(3) with $Na^+$ ions of four-, eight-, and six-rings are observed:Na(1)-Xe(2) = 3.09(6), Na(2)-Xe(3) = 3.11(2), and Na(3)-Xe(2) = 3.37(8) $\AA$. In each sodalite unit, one Xe atom is located at its center. In each large cavity, six Xe atoms are found, forming a distorted octahedral arrangement with four Xe atoms, at equatorial positions (each two at Xe(2) and Xe(3)) and the other two at axial positions (at Xe(4)). With various reasonable distances and angles, the existence of $(Xe)_6$ cluster is proposed (Xe(2)-Xe(3) = 4.78(6) and 4.94(7), Xe(2)-Xe(4) = 4.71(6) and 5.06(6), Xe(3)-Xe(4) = 4.11(3) and 5.32(4) $\AA$, Xe(2)-Xe(3)-Xe(2) = 93(1), Xe(3)-Xe(2)-Xe(3) = 87(1), Xe(2)-Xe(4)-Xe(2) = 91(4), Xe(2)-Xe(4)-Xe(3) = 55(2), 59(1), 61(1), and 68(1), and Xe(3)-Xe(4)-Xe(3) = 89($^{\circ}1$)). These arrangements of the encapsulated Xe atoms in the large cavity are stabilized by alternating dipoles induced on Xe(2), Xe(3), and Xe(4) by eight- and six-ring $Na^+$ ions as well as four-ring oxygens, respectively.

Kr Atoms and Their Chlustering in Zeolite A

  • Im, U Taek;Jang, Jang Hwan;Jeong, Gi Jin;Heo, Nam Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1023-1029
    • /
    • 2001
  • The positions of Kr atoms encapsulated in the molecular-dimensioned cavities of fully dehydrated zeolite A of unit-cell composition Cs3Na8HSi12Al12O48 (Cs3-A) have been determined. Cs3-A was exposed to 1025 atm of krypton gas at 400 $^{\circ}C$ for four days, followed by cooling at pressure to encapsulate Kr atoms. The resulting crystal structure of Cs3-A(6Kr) (a = $12.247(2)\AA$, R1 = 0.078, and R2 = 0.085) has been determined by single-crystal X-ray diffraction techniques in the cubic space group Pm3m at $21(1)^{\circ}C$ and 1 atm. In the crystal structure of Cs3-A(6Kr), six Kr atoms per unit cell are distributed over three crystallographically distinct positions: each unit cell contains one Kr atom at Kr(1) on a threefold axis in the sodalite unit, three at Kr(2) opposite four-rings in the large cavity, and two at Kr(3) on threefold axes in the large cavity. Relatively strong interactions of Kr atoms at Kr(1) and Kr(3) with Na+ ions of six-rings are observed: Na-Kr(1) = 3.6(1) $\AA$ and Na-Kr(3) = $3.08(5)\AA.$ In each sodalite unit, one Kr atom at Kr(1) was displaced $0.74\AA$ from the center of the sodalite unit toward a Na+ ion, where it can be polarized by the electrostatic field of the zeolite, avoiding the center of the sodalite unit which by symmetry has no electrostatic field. In each large cavity, five Kr atoms were found, forming a trigonal-bipyramid arrangement with three Kr(2) atoms at equatorial positions and two Kr(3) atoms at axial positions. With various reasonable distances and angles, the existence of Kr5 cluster was proposed (Kr(2)-Kr(3) = $4.78(6)\AA$ and Kr(2)-Kr(2) = $5.94(7)\AA$, Kr(2)-Kr(3)-Kr(2) = 76.9(3), Kr(3)-Kr(2)-Kr(3) = 88(1), and Kr(2)-Kr(2)-Kr(2) = $60^{\circ}).$ These arrangements of the encapsulated Kr atoms in the large cavity are stabilized by alternating dipoles induced on Kr(2) by four-ring oxygens and Kr(3) by six-ring Na+ ions, respectively.

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

SNU 1.5MV Van de Graaff Accelerator (IV) -Fabrication and Aberration Analysis of Magnetic Quadrupole Lens- (SNU 1.5MV 반데그라프 가속기 (IV) -자기 4극 렌즈의 제작과 수차의 분석-)

  • Bak, H.I.;Choi, B.H.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1986
  • A magnetic quadrupole doublet was fabricated for use at the pre-target position of SNU 1.5MV Van de Graaff accelerator and then its optical characteristics were measured and analysed. The physical dimensions are: pole length 180mm, aperture radius 25mm, pole tip radius 28.75mm. Material for poles and return yokes is carbon steel KS-SM40C. Coils have 480 turns per one pole and air-cooling is adopted. Applying the d.c. current 2.99$\pm$0.03A to the lens, and using the Hall probe, magnetic field elements $B_{\theta}$ , $B_{\gamma}$, were measured at the selected Points along each coordinate direction r,$\theta$, z. From the area integration and orthogonal polynomial fitting for the measured data, the magnetic Field gradient G=566.3$\pm$2.1 gauss/cm at lens center, the effective length L=208.3$\pm$1.44mm along the lens axis have been obtained. The harmonic contents were determined up to 20-pole from the generalized least squares fitting. The results indicate that sextupole/quadrupole is below 1.4$\pm$0.9% and all the other multipoles are below 0.5% in the region within 18mm radius at the center of lens.

  • PDF

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.