• 제목/요약/키워드: penetration pattern

검색결과 159건 처리시간 0.03초

공기보조 분사기와 고압 선회식 분사기의 특성 비교- Part 1:유량 및 거시적 분무특성 (Comparison of Overall Characteristics between an Air-Assisited Fuel Injector and a High-Pressure Swirl Injector-Part I: Flow rate and Macroscopic Spray Characteristics)

  • 장창수;최상민
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.20-27
    • /
    • 2000
  • Characteristics of two favorite injection tools for gasoline direct injection application were compared. An air-assisted fuel injector (AAFI) and a high-pressure swirl injector (HPSI) were designed and fabricated for prototype development, and the characterization strategies and processes for both injection tool have been arranged in parallel. Characterization works were carried out mainly through measurements, and in some cases, computational fluid dynamic analysis was utilized. In this paper, overall characteristics defined as flow rate, spray pattern, penetration, internal spray structure and drop size distribution, was discussed. The AAFI was found to be advantageous in flexibility of fuel flow rate, and the HPSI in stability and precision. Spray shape factor was introduced to describe the development of intermittent sprays from both injectors. Axial penetration appeared to be almost linear in the case of the AAFI while its speed continuously decreased with time in the HPSI.

  • PDF

연관마이닝 기법을 이용한 침입 시나리오 자동 탐지 알고리즘 연구 (The Study on the Automated Detection Algorithm for Penetration Scenarios using Association Mining Technique)

  • 김창수;황현숙
    • 한국정보통신학회논문지
    • /
    • 제5권2호
    • /
    • pp.371-384
    • /
    • 2001
  • 최근 인터넷 환경에서 시스템 불법 침입은 계속적으로 증가하고 있다. 이러한 침입을 탐지하기 위한 기법들은 크게 비정상 탐지와 오용 탐지로 분류할 수 있다. 전자는 통계적 방법, 특징 추출 등을 이용하며, 후자는 조건부 확률, 전문가 시스템, 상태 전이 분석, 패턴 매칭 둥을 적용한다. 현재 연구된 침입탐지 시스템들은 결합된 방법을 사용하고 있다. 본 연구에서는 상태전이 기법과 연관 마이닝 기법을 결합한 새로운 침입 탐지 알고리즘을 제안한다. 이를 위해 첫 번째 단계는 네트워크를 통해서 입력된 명령어에 대해서 상태 테이블을 작성하는데, 이는 기존의 상태전이 분석 방법과 유사하다. 다음 단계는 연관 마이닝 기법을 이용하여 침입의 유형을 판정한다. 이러한 처리 과정에 따라 본 연구에서는 자동화된 침입 시나리오 생성 알고리즘을 제안한다.

  • PDF

Impact of Electric Vehicle Penetration-Based Charging Demand on Load Profile

  • Park, Woo-Jae;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.244-251
    • /
    • 2013
  • This paper presents a study the change of the load profile on the power system by the charging impact of electric vehicles (EVs) in 2020. The impact of charging EVs on the load demand is determined not only by the number of EVs in usage pattern, but also by the number of EVs being charged at once. The charging load is determined on an hourly basis using the number of the EVs based on different scenarios considering battery size, model, the use of vehicles, charging at home or work, and the method of charging, which is either fast or slow. Focusing on the impact of future load profile in Korea with EVs reaching up 10 and 20 percentage, increased power demand by EVs charging is analyzed. Also, this paper analyzes the impact of a time-of-use (TOU) tariff system on the charging of EVs in Korea. The results demonstrate how the penetration of EVs increases the load profile and decreases charging demand by TOU tariff system on the future power system.

2차 가진 제어 변조분사 특성 및 액체제트의 분무특성 (Spray Characteristics of a Modulated Liquid Jet through 2nd Pulsed Control)

  • 강영수;이인철;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.672-675
    • /
    • 2010
  • 본 연구에서는 저주파영역의 가진분무에 대하여 추가적인 내부가진을 수행함으로써 변조분사되는 분무특성에 대한 연구를 수행하였다. 회전식 가진장치를 사용하여 1차 가진을 생성한 후 2차 가진원인 마그네틱 밸브를 사용하여 변조하였다. 변조분무의 FFT결과와 분무패턴의 가시화를 통하여 관찰한 결과, 2차 가진 제어가 있는 변조분사의 경우 1차 가진만 있는 분사보다 분무의 상하 운동 진폭이 작으며 분무 하단류의 침투깊이가 증가하는 경향성이 발견되었다.

  • PDF

콘크리트 벽의 비파괴검사를 위한 초광대역 레이더의 2차원 FDTD 시뮬레이션에서 안테나 모델링의 영향 (Effects of Antenna Modeling in 2-D FDTD Simulation of an Ultra-Wide Band Radar for Nondestructive Testing of a Concrete Wall)

  • 주정명;홍진영;신상진;김동현;오이석
    • 한국전자파학회논문지
    • /
    • 제24권1호
    • /
    • pp.98-105
    • /
    • 2013
  • 본 논문에서는 초광대역 벽 투과 레이더를 이용한 벽 내부 진단에 대한 유한차분 시간영역(finite-difference time-domain, FDTD) 시뮬레이션과 데이터 처리 기술에 대한 연구를 소개한다. 본 연구에서는 2차원 FDTD 기법을 이용하여 실제 측정과 유사한 조건으로 시뮬레이션을 수행하기 위해 우선 전파의 감쇄, 투과 특성, 해상도 등을 고려하여 0.3~7 GHz의 초광대역을 갖는 반대 극성 비발디 안테나(anti-podal vivaldi antenna)를 설계/제작하였다. 다음으로 제작된 안테나의 방사 패턴을 측정한 후 이것을 FDTD 시뮬레이션의 소스로 사용하여 콘크리트 벽 경계면과 벽 내부의 금속으로부터 반사된 데이터를 얻었다. 다음으로 이 데이터를 처리하고 레이더 영상을 생성하여 벽 내부를 관찰하였다. FDTD 시뮬레이션에서는 일반적으로 사용되고 있는 등방성 점 소스와 다항식으로 측정된 방사 패턴을 근사화하여 소스로 적용한 2가지 경우에 대해 비교하였으며, 그 결과, 안테나 패턴을 적용했을 경우 등방성 점 소스를 사용한 경우에 비해 최대 약 2.5 dB 높은 신호 대 잡음비를 얻을 수 있었다.

Effects of Mono- and Polysaccharides on In Vitro Fertility of Boar Spermatozoa

  • Hwang, In-Sun;Cheong, Hee-Tae;Yang, Boo-Keun;Kim, Choung-Ik;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • 제31권2호
    • /
    • pp.115-120
    • /
    • 2007
  • This study was conducted to examine the effect of several saccharides on the induction of capacitation and acrosome reaction (AR) and to examine the effects of mono and polysaccharides on the penetration activity of boar spermatozoa. Spermatozoa were inseminated in medium with fucose, galactose and mannose as monosaccharide, and fucoicIan. galactan and marman as polysaccharide. The penetration rates were significantly (p<0.05) lower in medium with galactose (40.6%), mannose (38.1%), fucose (41.6%) and fucoidan (36.6%) compared with control (56.7%). The rates of AR were increased (40.7 to 59.8%) by the preincubation periods prolonged from 0 to 4 hr (p<0.05). Similar tendencies were observed in AR when spermatozoa were treated with monosaccharides, but not significantly differ among the groups treated with different time of preincubation with some exception of galactose. When spermatozoa were treated with polysaccharides, the rates of AR were significantly (p<0.05) increased by preincubation time prolonged from 0 to 4 hr with an exception of fucoidan. In conclusion, the present study suggests that penetration rate of spermatozoa is higher in presence of polysaccharides than monosaccharides. Also, it may resume that the comparing to control, the all saccharides (L-fucose, D-galactose, D-mannose, fucoidan. galactan and mannan)-treated groups slightly increase the AR pattern as preincubation time prolonged.

스프레이 특성에 가솔린 - 바이오 디젤 혼합 연료의 효과 (The effects of Gasoline-Biodiesel Blended Fuels on Spray Characteristics)

  • 삭다 통사이;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제26권3호
    • /
    • pp.287-293
    • /
    • 2015
  • The current study has investigated the effects of biodiesel blended with gasoline on the spray characteristics in a Constant Volume Combustion Chamber (CVCC). With the concentration of 5, 10, 15 and 20% by volume, biodiesel was blended with commercial gasoline and performed on the macroscopic visualization test. Pure gasoline and biodiesel were also tested as the reference. The shadowgraph technique was conducted in the constant volume chamber. The spray images were recorded by a high speed video camera with frame speed 10,000 frame per second. Fuel injection was set at 800, 1000 and 1,350 bar with the simulated speed 1,500 and 2,000 rpm. The back pressure was controlled at 20 bar. The spray angle and penetration tip were measured and analyzed by using the image processing. At the high injection pressure, the spray penetration length with the simulated speed 1,500 rpm showed that B100 was lower than GB00-20 whereas the spray penetration length with the simulated speed 2,000 rpm exhibited that GB blends and B100 were insignificantly different. Due to biodiesel concentration, its effects on spray angles were observed throughout injection periods (T1, T2 and T3). At the simulated speed 1,500 rpm, the spray angle of GB blends and B100 presented the same pattern following injection timing. In addition, when the simulated speed increased to 2,000 rpm the different spray angle of all blends disappeared at main injection (T3).

다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도 (MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH)

  • 박수만;이재용;한승렬;하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.

물에 잠긴 다공 직사각평판의 실험적 모드 해석 (Experimental Modal Analysis of Perforated Rectangular Plates Submerged in Water)

  • 유계형;이명규;정경훈;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.416-421
    • /
    • 2002
  • This paper dealt with an experimental study on the hydro-elastic vibration of clamped perforated rectangular plates submerged in water. The penetration of holes in the plates had a triangular pattern with P/D (pitch to diameter) 1.750, 2.125, 2.500, 3.000 and 3.750. The natural frequencies of the perforated plates in air were obtained by the analytical method based n the relation between the reference kinetic and maximum potential energy and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plates in air. It was empirically found that the natural frequencies of the perforated plate in air increase with an increase of P/D, on the other hand, the natural frequencies of the perforated plate in contact with water decrease with an increase of P/D. Additionally, the effect of the submerged depth on the natural frequency was investigated.

  • PDF

다짐된 모래-벤토나이트 혼합토의 인장강도와 산성도에 따른 혼합토의 균열패턴에 관한 연구 (A Study of Tensile Strength on Compacted Sand-Bentonite Mixtures and Mixture's Crack Pattern with pH Levels)

  • 정수정;김찬기;김태형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1090-1099
    • /
    • 2006
  • Tensile strength of soil is one of the important strength parameters in geotechnical engineering. The importance of the tensile strength of soil has been pointed out and given considerable attention in many highway pavements and earthfill dams. Recently, one of tensile strength problems, cracking failure of clay liners which is related to leakage of polluted water has been reported. Thus, the tensile strength of compacted sand-bentonite mixtures, which are used widely in the landfill construction site as clay liners was measured by Improved Unconfined Penetration (IUP) test. In addition, to find out the effects of contamination levels of water on the tensile strength and desiccation crack pattern, different pH levels of water were used for making specimens prepared with three different mixing contents of bentonite.

  • PDF