• Title/Summary/Keyword: penetration amounts

Search Result 51, Processing Time 0.023 seconds

The Amounts of the Electromagnetic Wave Penetrating From a Cellular Phone under the Conditions of Wearing - Inside the Pocket of Men's Dress shirt - (착의 상태에 따른 휴대폰의 전자파 투과량 - 남성용 드레스 셔츠 포켓 내에서를 중심으로 -)

  • 송명견
    • The Korean Journal of Community Living Science
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2002
  • This study was conducted to estimate the amounts of the electromagnetic wave penetrating from a cellular phone in a pocket of dress shirt, as well as to test how different the penetration amounts were under the conditions of wearing. It was also investigated the possibilities that the amounts of the electromagnetic wave penetrating could be decreased by using twofold pocket or electromagnetic wave free fabric. The amounts of the electromagnetic wave penetrating were measured in the following five cases; one-layered pocket with 10 different fabrics as dress shirt, a pocket adding a layer of knitted cotton, two-layered pocket with same fabric as dress shirt, two-layered pocket adding a layer of knitted cotton, and one-layered pocket adding a layer of electromagnetic wave free fabric. Each of these five cases were measured using the front and back sides of a cellular phone facing to the body. The results were as follows; 1) The amounts of the electromagnetic wave penetrating were not significantly different in 10 different fabrics and were all above the caution range (0.02mW/$cm^2$). 2) The amounts of the electromagnetic wave penetrating in cases of the back side of the cellular phone to the body, were more than in cases of the front side. 3) There is a significantly differences in part on adding a knitted under wear to one and two layers of the pocket in the case of penetration amount under the wearing conditions. 4) The amounts of the electromagnetic wave penetrating in cases of adding a layer of electromagnetic wave free fabric, were close to the safe standard value of it. The above results suggested that facing the front side of cellular phone to the body and using extra layering with some electromagnetic wave free fabrics might have some protective effects again to the penetration amounts.

  • PDF

Comparison of Drug Delivery using Hairless Mouse and Pig Skin (Hairless Mouse와 Pig Skin을 활용한 약물 투과성 비교)

  • Cho, Wan-Goo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.410-415
    • /
    • 2007
  • Functional cosmetics are intensively investigated for the effectiveness of skin whitening, anti-aging and slimming. For enhancing the effectiveness, active ingredients should be delivered into the cell in the dermis. The amounts of penetration of caffeine and $Arbutin^{(R)}$ were tested, in vitro, using Franz diffusion cell. Oil-in-water emulsions were used for the vehicles of the transport. For the measuring the amounts of active ingredients delivered into the dermal skin, tape stripping was done after finishing the penetration experiments. The amounts of delivered caffeine were $8.45{\pm}$ 1.26ug/ml before tape stripping and $3.45{\pm}$ 1.80ug/ml after tape stripping, however, the amounts of delivered $Arbutin^{(R)}$ was quite small to detect. From now on, proper vehicles are considered for enhancing the delivery of $Arbutin^{(R)}$ Hairless mouse skin was compared with pig skin as a transdermal delivery membrane. The aspects of delivery were similar, but the amount of delivered ingredients using pig skin was larger than that of using hairless mouse skin. Therefore, the pig skin would be considered as a membrane for drug delivery experiments.

Use of the Stratum Corneum Reservoir for the Prediction of Skin Penetration

  • Cholee, Ae-Ri;Tojo, Kakuji
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 1993
  • A simple and quick method based on the transient diffusion theory for predicting the steady state rate of penetration of a drug after transdermal drug administration was proposed. The amount of drug entering the stratum corneum was determined by 20 strippings with an adhesive tape. From the profile of the amount of drug as a function of the number of strippings, the quantity of drug on the surface of stratum corneum was extrapolated. Based on the amounts of drug entering the stratum corneum during two time intervals $(t_1\;and\;t_2)$ within 1 hour after the application, the diffusion and partition coefficient were determined. Once the diffusion coefficient of the drug in the stratum corneum and the partition coefficient (stratum corneum/vehicle) were determined from the present approach, the steady-state flux of penetration across the stratum corneum was calculated. The steady-state rates of penetration of ascorbic acid and estradiol across hairless mouse skin were evaluated from this approach and compared with those obtained from ill vitro penetration experiment using excised hairless mouse skin. The data confirmed that the proposed method can predict the steady-state rate of penetration of these drugs across the stratum corneum.

  • PDF

Field Model Tests on Frost Penetration Depths and Frost Heave Amounts in Ballast track and Concrete track (현장모형실험을 통한 자갈궤도와 콘크리트궤도의 동결심도 및 동상량 측정)

  • Kim, Young-Chin
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.506-514
    • /
    • 2016
  • Experimental ballast track and concrete track were installed on the railway site and the frost penetration depth and the frost heave amount in the winter were measured. As a result, when the freezing index was the same, the frost penetration depth of concrete track was deeper than that of ballast track. Furthermore, when an XPS and polyethylene aggregate layer was installed below the ballast track, the frost penetration depth of the ballast track decreased significantly; in the case of the concrete track, the frost penetration depth decreased when the thickness of the subbase increased. Meanwhile, the frost heave amount also decreased when an XPS and polyethylene aggregate layer was installed below the ballast track ; in the case of the concrete track, the frost heave amount decreased when the thickness of the subbase increased.

Penetration of Some Humectants into Shark Muscle (상어육(肉)중의 수분유지제(水分維持劑) 침투(浸透))

  • Lee, Jong-Soo;Koo, Jae-Keun;Cha, Yong-Jun;Lee, Eung-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.475-481
    • /
    • 1984
  • Estimation of the penetration rate of humectants has been considered to be important in effective control of food processing when intermediate moisture food is manufactured by the moist-infusion method. In this study, when shark (Isurus glaucus) muscle was soaked in four common humectants (sucrose, sorbitol, glycerol, and propylene glycol), the equation of their penetration rate was drawn as a function of time using high performance liquid chromatography analysis. Penetration rates increased with soaking temperatures and decreased inversely with molecular weights of humectants. The penetrated amounts for 10% humectant solution reached about equilibrium after soaking for 10 hours and for 30% humectant after soaking for about 7 hours. In consideration with the penetration rate of the sample soaked in 10% humectant and complex solution of each 10% humectant, little difference was found between them. When the sample was soaked in 10% humectant and 30% humectant, it seemed to be able to apply the following regression equation to estimate the penetrated amounts: M = a log (c.t)+ b where M = penetrated amounts; c = concentration of humectant; t= soaking time; a, b = constant and c.t should be within $10^3\;-\;4{\times}10^4$.

  • PDF

Topical Delivery of Budesonide Emulsion Particles in the Presence of PEO-PCL-PEO Triblock Copolymers

  • Cho, Jin-Hun;Baek, Hyon-Ho;Lee, Jung-Min;Kim, Jung-Hyun;Kim, Dae-Duk;Cho, Heui-Kyoung;Cheong, In-Woo
    • Macromolecular Research
    • /
    • v.17 no.12
    • /
    • pp.969-975
    • /
    • 2009
  • This article describes the topical delivery and localization of budesonide through the hairless mouse skin. Two poly(ethylene oxide)-block-poly($\varepsilon$-caprolactone)-block-poly(ethylene oxide) (PEO-PCL-PEO) triblock copolymers (T 222 and T 252) having different CL:EO ratios were added in the preparation of budesonide particles stabilized with poly(vinyl alcohol) (PVA) and Tween 80 under ultrasonication. For comparison, a commercial PEO-PPO-PEO triblock copolymer (F68) was studied under the same condition. To demonstrate the effects of the triblock copolymer, the particle size of budesonide emulsion, entrapment efficiency, and in vitro release were measured and compared. The budesonide particles stabilized by the triblock copolymers had a diameter of ca. 350 nm with entrapment efficiencies of 66-76%. The In vitro release profiles of all samples showed an initial burst followed by sustained release. The skin penetration and permeation of budesonide were analyzed by using a Frantz diffusion cell. T 222 and T 252 exhibited higher total permeation amounts, but lower budesonide penetration amounts, than F68. The results suggest that the partitioning of budesonide in each skin layer can be adjusted in order to avoid skin thinning and negative immune response arising from the penetration of budesonide in blood vessels.

Effects of Fine Aggregate Size on Penetration Performances of SSPM (잔골재의 입도분포가 SSPM의 침투성능에 미치는 영향)

  • Yoon, Hyun-Kwang;Youn, Da-Ae;Lee, Chan-Woo;Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.25-31
    • /
    • 2019
  • This study was conducted to evaluate the penetration performance of the Silane Surface Protection Material (SSPM) penetrating the micro pore of concrete surface. The results was indicated microstructure, porosity and penetration depth of applied SSPM. Silica sand and conventional sand were used as fine aggregate in mortar. And liquid and cream types SSPM were used. The amounts of SPM were applied the 127, 255, 382, 510 g/m2 on the surface of mortar. The penetration depth specimens were made with $100{\times}30mm$ in according with KS F 4930. Penetration depth was evaluated according to KS F 4930, divide specimen and then spraying with water in cross section of specimens, and measure the depth of the non-wetted area. The microstructure result of mortar applied SSPM, it was obtained liquid and cream SSPM in mortar. The porosity results of SSPM application specimens were improved with than that of plain specimens. Test results indicated that the penetration depth of SPM were improved with increasing in amounts of SSPM. As a result of test, application of SSPM to concrete surface, it will improve durability.

The Effects of Enhancers on Transdermal Absorption of Ketoprofen Packs (케토프로펜 팩제제에서 경피흡수에 미치는 투과촉진제의 영향)

  • Cho, Su-Jin;You, Do-Ra;Kim, Kil-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.2
    • /
    • pp.107-112
    • /
    • 2001
  • In order to reduce the systemic side effects and gastrointestinal irritation after its oral adminitration, ketoprofen was formulated as water-soluble packs. The effects of fatty acids and fatty alcohols on the penetration of ketoprofen through excised rat skins were evaluated. The role of stratum corneum as a protective barrier was also investigated. Fatty acids and fatty alcohols were generally effective in promoting ketoprofen penetration. The flux of ketoprofen through rat skin was maximized when oleic acid or lauryl alcohol was used as an enhancer. As the concentration of fatty acids and fatty alcohols varied from 0% to 10%, the amounts of ketoprofen penetrated were in direct proportion to that of fatty acids but those had no relationship with that of fatty alcohols. The penetration of ketoprofen through stripped skin was enhanced compared to normal skin irrespective of enhancer type, which indicated that the action site of enhancers would be stratum corneum.

  • PDF

Physical Charateristics of Elastomer Modified Asphalt (탄성체로 개질된 아스팔트의 물리적 특성)

  • Lee, S.J.;Lee, S.J.;Lee, J.K.
    • Elastomers and Composites
    • /
    • v.32 no.3
    • /
    • pp.166-172
    • /
    • 1997
  • The objective in this study was investigated temperature susceptibility and low temperature fracture of rubber modified asphalt. A chlorinated polyethylene elastomer, Tyrin CM0730, was added to 200/300 grade asphalt with 3.0 and 5.0wt% to improve campatibility. The elastomer modified asphalts were analyzed for temperature susceptibility relating to penetration index(PI) and penetration-viscosity number(PVN) as well as low temperature fracture relating to fracture energy $(G_{IC})$. These indices were obtained from the measurements of penetration, viscosity, failure load and modulus. The addition of small amounts of elastomer to the asphalt resulted in a significant increase of both the PI and PVN over an unmodified asphalt. Also, the fracture energy increased with the addition of elastomer to asphalt. These significant improvement at both the high and low temperature result in enhanced performance.

  • PDF

Skin Permention of Ketoprofen from Lotion (케토프로펜 로오숀으로부터 약물의 피부투과)

  • 단현광;이윤석;박은석;지상철
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.357-363
    • /
    • 1997
  • The effects of formulation variables of topical lotion on the skin permeation of ketoprofen were evaluated using excised rat skins. The formulation variables were the amounts of poloxamer 407, drug and ethanol, and penetration enhancers. The Keshary-Chien diffusion cells were used for the diffusion study. The flux of ketoprofen linearly decreased as the concentration of poloxamer increased from 5% to 15% in the preparation, and linearly increased as the amount of drug increased. Penetration enhancers such as fatty acids and fatty alcohols showed markedly enhancing effects at the level of 5%. Among them, the highest flux was shown in linolenic acid. From these results, optimum formula containing 3% ketoprofen, 5% poloxamer 407, 40% ethanol and 5% linolenic acid having the flux of 537.6 $\mu$g/$\textrm{cm}^2$/hr were noted.

  • PDF