• Title/Summary/Keyword: pelvis

Search Result 778, Processing Time 0.027 seconds

Hypofractionated intensity-modulated radiotherapy in patients with localized prostate cancer: a preliminary study

  • Kang, Hye Jin;Kay, Chul-Seung;Son, Seok Hyun;Kim, Myungsoo;Jo, In Young;Lee, So Jung;Lee, Dong Hwan;Suh, Hong Jin;Choi, Yong Sun
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • Purpose: The aim of this work was to assess the efficacy and tolerability of hypofractionated intensity-modulated radiotherapy (IMRT) in patients with localized prostate cancer. Materials and Methods: Thirty-nine patients who received radical hypofractionated IMRT were retrospectively reviewed. Based on a pelvic lymph node involvement risk of 15% as the cutoff value, we decided whether to deliver treatment prostate and seminal vesicle only radiotherapy (PORT) or whole pelvis radiotherapy (WPRT). Sixteen patients (41%) received PORT with prostate receiving 45 Gy in 4.5 Gy per fraction in 2 weeks and the other 23 patients (59%) received WPRT with the prostate receiving 72 Gy in 2.4 Gy per fraction in 6 weeks. The median equivalent dose in 2 Gy fractions to the prostate was 79.9 Gy based on the assumption that the ${\alpha}/{\beta}$ ratio is 1.5 Gy. Results: The median follow-up time was 38 months (range, 4 to 101 months). The 3-year biochemical failure-free survival rate was 88.2%. The 3-year clinical failure-free and overall survival rates were 94.5% and 96.3%, respectively. The rates of grade 2 acute genitourinary (GU) and gastrointestinal (GI) toxicities were 20.5% and 12.8%, respectively. None of the patients experienced grade ${\geq}3$ acute GU and GI toxicities. The grade 2-3 late GU and GI toxicities were found in 8.1% and 5.4% of patients, respectively. No fatal late toxicity was observed. Conclusion: Favorable biochemical control with low rates of toxicity was observed after hypofractionated IMRT, suggesting that our radiotherapy schedule can be an effective treatment option in the treatment of localized prostate cancer.

Locally Advanced Rectal Carcinoma : Curative Surgery Alone vs. Postoperative Radiotherapy and Chemotherapy (국소적으로 진행된 직장암에 대한 근치적 수술 단독 치료군과 수술후 보조적 방사선 및 항암화학요법 병행군의 치료결과 분석)

  • Ahn Seung Do;Choi Eun Kyung;Kim Jin Cheon;Kim Sang Hee
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.253-258
    • /
    • 1995
  • Purpose : To evaluate the effects of postoperative radiotherapy and chemotherapy on the pattern of failure and survival for locally advanced rectal carcinoma, we analyzed the two groups of patients who received curative resection only and who received postoperative radiochemotherapy retro-spectively. Materials and Methods : From June 1989 to December 1992, ninety nine patients with rectal cancer were treated by curative resection and staged as B2-3 or C. Group I(25) patients received curative resection only and group II(74) patients postoperative adjuvant therapy. Postoperative adiuvant group received radiation therapy (4500cGy/25fx to whole pelvis) with 5-FU (500mg/$m^2$, day 1-3 IV infusion) as radiosensitizer and maintenance chemotherapy with 5-FU(400mg/$m^2$ for 5 days) and leucovorin (20mg/m^2$ for 5 days) for 6 cycles. Results : The patients in group I and group II were comparable in terms of age sex, performance status, but in group II $74{\%}$ of patients showed stage C compared with $56{\%}$ of group I. All patients were followed from 6 to 60 months with a median follow up of 29 months. Three year overall survival rates and disease free survival rates were $68\%,\;64\%$ respectively in group I and $64\%,\;61\%$, respectively in group II. There was no statistical difference between the two treatment groups in overall survival rate and disease free survival rate. Local recurrences occurred in $28{\%}$ of group I, $21{\%}$ of group II (p>.05) and distant metastases occurred in $20{\%}$ of group I, $27{\%}$ of group II(p>.05). The prognostic value of several variables other than treatment modality was assessed. In multivariate analysis for prognostic factors stage and histologic grade showed statistically significant effect on local recurrences and lymphatic or vessel invasion on distant metastasis. Conclusion : This retrospective study showed no statistical difference between two groups on the pattern of failure and survival. But considering that group II had more advanced stage and poor prognostic factors than group I, postoperative adjuvant radiochemotherapy improves the results for locally advanced rectal carcinoma as compared with curative surgery alone.

  • PDF

A Case of Cystinuria with Multiple Renal Stones in an 8-month-old Girl (8개월 여아에서 다발성 결석으로 진단된 시스틴뇨증 1례)

  • Kang, Eun Gu;Lee, Joo Hoon;Lee, Beom Hee;Kim, Gu-Hwan;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.122-126
    • /
    • 2013
  • Cystinuria is an autosomal recessive disease characterized by impaired transport of cystine and dibasic amino acids in the proximal renal tubule, resulting in the formation of cystine stones. It is believed to account for about 1% of all kidney stones and up to 10% of pediatric stones. Here we report a case of cystinuria with multiple renal stones confirmed by genetic mutational analysis. An 8-month-old girl was admitted to AMC with persistent fever and multiple renal stones. A renal sonogram showed multiple stones at the right renal pelvis, right distal ureter, and left renal medullary portion. An approximately 1 cm renal stone was extracted spontaneously, and stone analysis revealed it to be composed entirely of cystine. Cystinuria was confirmed by increased urine dibasic amino acid levels, including cysteine, and genetic mutational analysis showed the patient to be a homozygote for the pathogenic c. 1820del (p.L607fs) of SLC3A1. Despite treatment with oral hydration and urinary alkalinization, and restricted intake of animal protein, the stones increased in size and number. The patient has since been treated with tiopronin.

Radioimmunoscintigraphy Using IMACIS-1 in Gastrointestinal Cancer (IMACIS-1을 이용한 위장관 종양의 방사면역신티그램)

  • Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 1990
  • Most of the diagnostic methods currently used for the detection of neoplastic masses provide indirect evidence. To obtain greater specificity in the interpretation of neoplasias by in vivo methods, the immunological approach appears to be most promising. Two problems that interfered with progress in this field were the lack of tumor specific antigen and the lack of well-defined and reproducible antibodies. To improve the sensitivity and specificity of radioimmunoscintigraphy as a technique for tumor localization, the use of monoclonal antibodies, fragments of antibodies and single photon emission computerized tomography (SPECT) are reasonable. The obvious advantages of monoclonal antibodies are their homogeneity, their specificity for the immunizing antigen and the reaction with a single determinant-thus no large immunecomplexes with antigen are formed. Monoclonal antibody technique has recently provided an opportunity to reevaluate the role of nuclear medicine for the diagnosis of malignant diseases by using the immunological approach. Out first results by means of radioimmunoscintigraphy of CEA and CA 19-9 producing tumors using a cocktail of fragments F $(ab')_2$, of mocolonal antibodies to CA 19-9 and CEA labeled with $^{131}I$ (IMACIS-1) are reported. The aims of this investigation was to evaluate the role of immunoscintigraphy in patients with colorectal and other cancers for diagnosis of local recurrences and metastasis. This report contains results of the first 8 colorectal and pancreas cancer patients with the elevation of the level of serum CEA and/or CA 19-9. IMACIS-1 was injected intravenously during 30 minutes in 100 ml saline solution after skin test. Planar scintigrams were recorded 3, 5 and 7 days after the injection of the IMACIS-1. Anterior, lateral and posterior views of the liver as well as anterior and posterior views of the pelvis were obtained in each patients as an $^{131}I-antibody$ image. We were able to localize exactly the malignant process with the double-nuclide double-compound $^{99m}Tc\;^{131}I$ (Tc+l) scintigrams. In Tc & I double-nuclide scintigraphy, computer subtraction display provided more clear localization of the tumor. We compared the results of radioimmunoscintigraphy with CT, ultrasonograms, conventional scintigrams. The results were as follows: 1) The sensitivity and specificity of radioimmunoscintigraphy using the fragments $F(ab')_2$ of the cocktails of CEA and CA 19-9 monoclonal antibodies were 80% and 100% respectively. 2) Tumor detection rate was not proportionated to the level of serum tumor markets. 3) Second tracer technique was essential for tumor localization as an anatomic landmark using double-nuclide scintigraphy. 4) A slow infusion of the antibodies was necessary to prevent the formation of large immune complexes. 5) Tumor/non-tumor radioactivity was most elevated at 7 days delayed imaging. 6) Using planar scintigraphic technique of $^{131}I$ labeled monoclonal antibodies are possible for imaging most of the tumors.

  • PDF

Usability Evaluation through Gonad Shielding Production of Pediatric Patients by Gender and Age Rating (소아 환자의 성별과 연령별 생식선 차폐체 제작을 통한 유용성 평가)

  • CHOI, Sung-Hyun;PARK, Jung-Eun;Dong, Kyung-Rae;Chung, Woon-Kwan;Ju, Yong-Jin;Yang, Nam-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.69-75
    • /
    • 2015
  • Purpose: The gonad shielding is used to minimize the impact of the exposure to gonads when Abdomen, Pevis and Hip X-ray inspections are conducted on radiation impressionable pediatric patients. By the way, the gonad is palpable difficult and impossible to check visually because it's a sensitive area, so tests are conducted with the approximate location of shielding, thereby appearing problems of not shielding gonads accurately. Accordingly, this study produced shields by age and gender of pediatric patients and studied the method of positioning shields with ASIS as a reference point without palpable sensitive areas, and tried to evaluate its usability. Materials and methods: The study surveyed 30 pediatric patients by gender and age, who came and got inspected in Department of Radiology, our hospital from February 2012 to January 2014 and obtained the value of tolerance by measuring the average size of the pelvis using the distance measurement function of Infinitt Piview with the images stored in the PACS and producing shields by age and gender of pediatric patients and specifying the areas at random for the comparative analysis of pre- and post-using. It calculated the technology statistics($mean{\pm}SD$) with the value of tolerance measured the length using SPSS 12.0 statistical program. Results: As for boys, differences in the tolerance range of pre- and post-using shields were 2.69 mm in case of 1 year old, 2.58 mm in 2 years, 2.37 mm in 3 years, 2.815 mm in 4~5 years, 2.043 mm in 7~10 years, and as for girls, 1.92 mm in 1~2 years, 1.75 mm in 3~4 years, 2.52 mm in 5~6 years and 1.93 mm in 7~10. After analyzing the pre- and post-using shields for all of boys and girls, there were statistically significant differences(P<0.050). Conclusions: It is considered that we can minimize the exposure to gonads and get a better video for diagnosis in testing high biological impressionable pediatric, if we use shields correctly with ASIS as a reference point considering its shape and size by age and gender in Abdomen, Pevis and Hip X-ray inspections.

Biomechanical Comparison during Isolation Movement in B-boy and K-pop Dancers (B-boy와 K-pop 댄서 중심으로 한 분리 동작의 생체역학적 비교)

  • Jang, Young Kwan;Hong, Su Yeon;Jang, In Young
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.2
    • /
    • pp.91-99
    • /
    • 2017
  • The purpose of this study was to clarify the differences between the K-pop and B-boy dancers'characteristics based on the biomechanical variables through the isolation movement by independent variable t-test using spss 18.0. As a result, first, the CoM composite displacement of the K-pop dancer was larger than that of the B-boy(p<.05) in phase1 and phase2. Second, in phase2 and phase3, the movement speed of CoM was faster in K-pop dancer than in B-boy(p<.05). Third, in phase1, the planar angle between the body and pelvis was greater in the right planar angle of the K-pop dancer, while in the phase2 and phase3, the left planar angle of the B-boy was larger(p<.05). Fourth, the composite hip joint moments of B-boy were larger than those of K-pop in phase1, However, K-pop dancers showed greater moments in phase2, phase3 and phase4, and ankle joint moments in phase3(p<.05). Thus, even with the same isolation, we found that K-pop and B-boy dancers performed differently.

What is the Appropriate Kettlebell Mass for a Kettlebell Swing? (케틀벨 스윙 시 적당한 케틀벨의 무게는 얼마일까?)

  • Kim, Bo Kyeong;Thau, Dao Van;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.308-313
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the effect of different kettlebell mass (30%, 40%, and 50% of the body mass) on kinematics and kinetic variables of kettlebell swing. Method: Total of 16 healthy male who had at least 1 year of kettlebell training experience were participated in this study (age: 31.69 ± 3.46 yrd., height: 173.38 ± 4.84 cm, body mass: 74.53 ± 6.45 kg). In this study, a 13-segments whole-body model (upper trunk, lower trunk, pelvis, both side of forearm, upperarm, thigh, and shank) was used and 26 reflective markers were attached to the body to identify the segments during the movement. A 3-dimensional motion analysis with 8 infrared cameras and 4 channeled EMG was performed to find the effect of kettlebell mass on its swing. To verify the kettlebell mass effect, a one-way ANOVA with a repeated measure was used and the statistical significance level was set at 𝛼=.05. Results: Firstly, in all lower extremity joints and thoracic vertebrae, a statistically significant change in angle was shown according to an increase in kettlebell mass during kettlebell swing (p<.05). Secondly, in both the up-swing and down-swing phases, the knee joint and ankle joint ROM showed a statistically significant increase as the kettlebell mass increased (p<.05) but no statistically significant difference was found in the hip joint and thoracic spine (p>.05). Lastly, the hamstrings muscle activity was statistically significantly increased as the kettlebell mass increased during up-swing phases (p<.05). Also, as the kettlebell mass increased in P4 of the down swing phase, the gluteus maximus showed a statistically significantly increased muscle activation, whereas the rectus femoris showed a statistically significantly decreased muscle activation (p <.05). Conclusion: As a result of this study, hip extension decreased and knee extension increased at 40% and 50% of body mass, and the spine also failed to maintain neutrality and increased flexion. Also, when kettlebell swings are performed with 50% of body mass, synergistic muscle dominance appears over 30% and 40% of body mass, which is judged to have a risk of potential injury. Therefore, it is thought that for beginners who start kettlebell exercise, swing practice should be performed with 30% of body mass. In addition, even in the case of experienced seniors, as the weight increases, the potential injury risk may increase, so it is thought that caution should be exercised when performing swings with 40% and 50% of body mass. In conclusion, it is thought that increasing the weight after sufficiently training with 30% of the weight of all subjects performing kettlebell swing is a way to maximize the exercise effect as well as prevent injury.

A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector (장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구)

  • Kim, Woo-Young;Seo, Hyun-Soo;Han, Bong-Ju;Yoon, Myeong-Seong;Lee, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter.

Effect of Tiger Step on Lower Extremities during Uphill Walking (오르막보행 시 타이거스텝 하지 움직임에 미치는 영향)

  • Kang, Jihyuk;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.17-23
    • /
    • 2022
  • Objective: The aim of this study was to investigate the effect Tiger-step walking on the movement of the lower extremities during walking. Method: Twenty healthy male adults who had no experience of musculoskeletal injuries on lower extremities in the last six months (age: 26.85 ± 3.28 yrs, height: 174.6 ± 3.72 cm, weight: 73.65 ± 7.48 kg) participated in this study. In this study, 7-segments whole-body model (pelvis, both side of thigh, shank and foot) was used and 29 reflective markers and cluster were attached to the body to identify the segments during the gait. A 3-dimensional motion analysis with 8 infrared cameras and 7 channeled EMG was performed to find the effect of tigerstep on uphill walking. To verify the tigerstep effect, a one-way ANOVA with a repeated measure was used and the statistical significance level was set at α=.05. Results: Firstly, Both Tiger-steps showed a significant increase in stance time and stride length compared with normal walking (p<.05), while both Tiger-steps shown significantly reduced cadence compared to normal walking (p<.05). Secondly, both Tiger-steps revealed significantly increased in hip and ankle joint range of motion compared with normal walking at all planes (p<.05). On the other hand, both Tiger-steps showed significantly increased knee joint range of motion compared with normal walking at the frontal and transverse planes (p<.05). Lastly, Gluteus maximus, biceps femoris, medial gastrocnemius, tibialis anterior of both tiger-step revealed significantly increased muscle activation compared with normal walking in gait cycle and stance phase (p<.05). On the other hand, in swing phase, the muscle activity of the vastus medialis, biceps femoris, tibialis anterior of both tiger-step significantly increased compared with those of normal walking (p <.05). Conclusion: As a result of this study, Tiger step revealed increased in 3d range of motion of lower extremity joints as well as the muscle activities associated with range of motion. These findings were evaluated as an increase in stride length, which is essential for efficient walking. Therefore, the finding of this study prove the effectiveness of the tiger step when walking uphill, and it is thought that it will help develop a more efficient tiger step in the future, which has not been scientifically proven.

Three-Dimensional Printing Technology in Orthopedic Surgery (정형외과 영역에서의 삼차원 프린팅의 응용)

  • Choi, Seung-Won;Park, Kyung-Soon;Yoon, Taek-Rim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.103-116
    • /
    • 2021
  • The use of 3-dimensional (3D) printing is becoming more common, and its use is increasing in the orthopedic surgery. Currently, there are four major methods of using 3D printing technology in orthopedic surgery. First, surgical planning simulation using 3D printing model; second, patient-specific surgical instruments; third, production of customized prosthesis using 3D printing technique; fourth, patient-specific prosthesis produced by 3D printing. The areas of orthopedic surgery where 3D printing technology can be used are shoulder joint, spine, hip and pelvis, knee joints, ankle joint, and tumors. Since the diseases and characteristics handled by each area are different, the method of using 3D printing technology is also slightly different in each area. However, using 3D printing technology in all areas can increase the efficiency of surgery, shorten the surgery time, and reduce radiation exposure intraoperatively. 3D printing technology can be of great help in treating patients with particularly complex and difficult orthopedic diseases or fractures. Therefore, the orthopedic surgeon should make the most of the benefits of the 3D printing technology so that patient can be treated effectively.